The Keysight (formerly Agilent / HP) 6813A is a high-performance programmable AC power source and analyzer designed for applications requiring precise AC/DC power generation and detailed measurement capabilities. It provides a complete AC test solution with a built-in arbitrary waveform generator, precise power analyzer, and transient generation system, making it ideal for testing consumer electronics, power supplies, and avionics.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB (IEEE-488.2), RS-232 |
| Display | Vacuum Fluorescent Display (VFD) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 200 to 240 VAC, single-phase, 47 to 63 Hz |
| Operating Temperature | 0 to 40 °C |
| Dimensions (W×H×D) | 425.5 mm × 177.8 mm × 647.9 mm |
| Weight | 48.2 |
AC Output Specifications
| Parameter | Value |
|---|---|
| Maximum AC Power Rating | 1750 VA |
| Output Phase Configuration | Single-phase |
| AC Voltage Range (Low Range) | 0 to 135 Vrms |
| AC Voltage Range (High Range) | 0 to 270 Vrms |
| AC Voltage Resolution | 100 mV |
| AC Voltage Accuracy (Low Range) | ±(0.15% of output + 0.3 V) at 45 to 100 Hz |
| AC Voltage Accuracy (High Range) | ±(0.15% of output + 0.6 V) at 45 to 100 Hz |
| Maximum RMS Current (Low Range) | 13 A |
| Maximum RMS Current (High Range) | 6.5 A |
| Maximum Peak Current (Low Range) | 80 A |
| Maximum Peak Current (High Range) | 40 A |
| Frequency Range | 45 Hz to 1000 Hz |
| Frequency Resolution | 10 mHz (45.00 to 80.00 Hz), 100 mHz (80.1 to 1000.0 Hz) |
| Frequency Accuracy | ±0.01% |
| Total Harmonic Distortion (THD) | < 1% (45 to 100 Hz), < 2% (100 to 1000 Hz) |
| Voltage Line Regulation | 0.1% of full scale |
| Voltage Load Regulation | 0.5% (45 to 100 Hz) |
DC Output Specifications
| Parameter | Value |
|---|---|
| Maximum DC Power Rating | 1350 W |
| DC Voltage Range (Low Range) | 0 to ±180 V |
| DC Voltage Range (High Range) | 0 to ±360 V |
| DC Voltage Resolution | 100 mV |
| DC Voltage Accuracy (Low Range) | ±(0.1% of output + 0.5 V) |
| DC Voltage Accuracy (High Range) | ±(0.1% of output + 1.0 V) |
| Maximum DC Current (Low Range) | 10 A |
| Maximum DC Current (High Range) | 5 A |
| DC Ripple and Noise (RMS) | 2 Vrms (20 Hz to 10 MHz) |
Measurement & Readback
| Parameter | Value |
|---|---|
| Voltage Measurement Range (Low Range) | 0 to 135 Vrms |
| Voltage Measurement Range (High Range) | 0 to 270 Vrms |
| Voltage Measurement Accuracy (Low Range) | ±(0.15% of reading + 0.3 V) |
| Voltage Measurement Accuracy (High Range) | ±(0.15% of reading + 0.6 V) |
| Current Measurement Range (Low Range) | 0 to 13 A (RMS) |
| Current Measurement Range (High Range) | 0 to 6.5 A (RMS) |
| Current Measurement Accuracy (Low Range) | ±(0.5% of reading + 0.03 A) |
| Current Measurement Accuracy (High Range) | ±(0.5% of reading + 0.02 A) |
| Active Power (W) Measurement Accuracy (Low Range) | ±(1.5% of reading + 5 W) |
| Active Power (W) Measurement Accuracy (High Range) | ±(1.5% of reading + 24 W) |
| Apparent Power (VA) Measurement Accuracy (Low Range) | ±(1.5% of reading + 5 VA) |
| Apparent Power (VA) Measurement Accuracy (High Range) | ±(1.5% of reading + 24 VA) |
| Power Factor Measurement Accuracy | ±0.05 (for current > 1 A) |
| Crest Factor Measurement Accuracy | ±5% (for current > 1 A) |
| Harmonic Analysis Capabilities | 1st to 50th harmonic of fundamental (45 to 75 Hz) |
Transient & Waveform Generation
| Parameter | Value |
|---|---|
| Output Waveform Types | Sine, Square, Clipped-Sine, Arbitrary |
| Transient Generation Modes | Step, Pulse, List modes |
Protection Features
| Parameter | Value |
|---|---|
| Overcurrent Protection (OCP) Range | Programmable limit (shutdown or constant current) |
| Overtemperature Protection (OTP) | Yes |
| Remote Sense Maximum Cable Drop | Up to 2 V drop per lead |
Input Power Requirements
| Parameter | Value |
|---|---|
| Maximum Input Power | 3600 VA |
System Interfaces & Software
| Parameter | Value |
|---|---|
| Command Language | SCPI (Standard Commands for Programmable Instruments) |
Physical & Environmental Specifications
| Parameter | Value |
|---|---|
| Rack Height Units (U) | 4U |
| Storage Temperature Range | -40 °C to 75 °C |
| Cooling Method | Forced-air cooling via internal fan |
Input Power
| Parameter | Value |
|---|---|
| Input AC Voltage Options | 100 VAC / 120 VAC / 200 VAC / 208 VAC / 230 VAC / 240 VAC (option dependent) |
| Input Frequency Range | 48 Hz to 63 Hz |
Output Isolation
| Parameter | Value |
|---|---|
| Maximum Float Voltage | 450 V peak (output terminals to chassis) |
Analog Programming & Modulation
| Parameter | Value |
|---|---|
| External Analog Input Range | ±10 V peak full scale |
| External Analog Input Impedance | 100 kΩ nominal |
Arbitrary Waveform Generation
| Parameter | Value |
|---|---|
| User-Defined Waveform Points | 1024 points |
| Arbitrary Waveform DAC Resolution | 12-bit |
Measurements
| Parameter | Value |
|---|---|
| Peak Current Measurement Resolution | 0.1 A |
| RMS Voltage Measurement Resolution | 0.01 V |
| RMS Current Measurement Resolution | 0.001 A (low range), 0.01 A (high range) |
| Crest Factor Measurement Resolution | 0.1 |
| Power Factor Measurement Range | 0.00 to 1.00 |
| Power Factor Measurement Resolution | 0.01 |
Environmental
| Parameter | Value |
|---|---|
| Operating Humidity Range | Up to 95% RH (non-condensing) |
| Maximum Operating Altitude | 2000 m |
System Settings
| Parameter | Value |
|---|---|
| Store/Recall States | 10 states (0 to 9) |
Power Input
| Parameter | Value |
|---|---|
| Input Power Factor | 0.99 typical at full load |
Measurement
| Parameter | Value |
|---|---|
| Total Harmonic Distortion (THD) Measurement Resolution | 0.1% |
| Phase Angle Measurement Range | -180.0° to +180.0° |
| Phase Angle Measurement Resolution | 0.1° |
| Phase Angle Measurement Accuracy | ±1.5° (for fundamental frequency 45 Hz to 65 Hz) |
| Harmonic Analysis Range | 1st to 50th harmonic |
| Harmonic Amplitude Resolution | 0.01% of full scale |
| Harmonic Voltage Measurement Accuracy | ±(0.03% of full scale + 0.1% of reading) for 1st to 25th harmonic (with 45 Hz to 65 Hz fundamental) |
| Harmonic Current Measurement Accuracy | ±(0.3% of full scale + 0.6% of reading) for 1st to 25th harmonic (with 45 Hz to 65 Hz fundamental) |
| Reactive Power (var) Measurement Range | 1750 var |
Output Specifications
| Parameter | Value |
|---|---|
| AC Output Voltage Temperature Coefficient | 0.04% / °C |
I/O Ports
| Parameter | Value |
|---|---|
| Trigger Input Connector | 15-pin D-sub, TTL compatible |
| Trigger Output Connector | 15-pin D-sub, TTL compatible |
Technology
Programmable Linear/Switching Hybrid AC Source
Applications
AC Power Testing, Power Supply Testing, Harmonic Analysis, Avionics Testing