The Keysight 6813B is a highly versatile, single-phase AC Power Source and Power Analyzer designed for demanding applications such as power supply testing, UPS evaluation, avionics ATE, and power factor corrected equipment testing. Delivering up to 1750 VA AC power and 1350 W DC power, it integrates the functionality of an AC/DC source, arbitrary waveform generator, and a comprehensive harmonic power analyzer into a single 4U chassis.
Specifications
AC Output Specifications
| Parameter | Value |
|---|---|
| Maximum AC Power Rating | 1750 VA |
| AC Voltage Ranges | 135 Vrms / 270 Vrms |
| AC Voltage Range (Low) | 0 to 135 Vrms |
| AC Voltage Range (High) | 0 to 270 Vrms |
| Maximum AC RMS Current (Low Range) | 13 A |
| Maximum AC RMS Current (High Range) | 6.5 A |
| AC Output Frequency Range | 45 Hz to 1000 Hz |
| Maximum Peak Current (Low Range) | 40 A |
| Maximum Peak Current (High Range) | 20 A |
DC Output Specifications
| Parameter | Value |
|---|---|
| Maximum DC Power Rating | 1350 W |
| DC Voltage Ranges | 190 V / 380 V |
| DC Voltage Range (Low) | 0 to 190 V |
| DC Voltage Range (High) | 0 to 380 V |
| Maximum DC Current (Low Range) | 10 A |
| Maximum DC Current (High Range) | 5 A |
Measurement Capabilities (Analyzer Function)
| Parameter | Value |
|---|---|
| DC Voltage Measurement Accuracy (Low Range) | ±(0.1% of reading + 0.5 V) |
| DC Voltage Measurement Accuracy (High Range) | ±(0.1% of reading + 1 V) |
| Active Power Measurement Accuracy (45 to 100 Hz, PF = 1) | ±(1.5% of reading + 17.5 W) |
| Apparent Power Measurement Accuracy (45 to 100 Hz) | ±(1.5% of reading + 17.5 VA) |
| Power Factor Measurement Range | 0.00 to 1.00 |
| Harmonic Amplitude Measurement Range | Fundamental to 50th harmonic |
Programming Accuracy and Resolution
| Parameter | Value |
|---|---|
| AC Voltage Programming Accuracy (Low Range, 45 to 100 Hz) | ±(0.15% of output + 0.3 V) |
| AC Voltage Programming Accuracy (High Range, 45 to 100 Hz) | ±(0.15% of output + 0.6 V) |
| DC Voltage Programming Accuracy (Low Range) | ±(0.1% of output + 0.5 V) |
| DC Voltage Programming Accuracy (High Range) | ±(0.1% of output + 1 V) |
| Frequency Programming Resolution | 10 µHz |
Input Power Requirements
| Parameter | Value |
|---|---|
| Input Phase Configuration | Single-phase |
| Input AC Frequency Range | 47 to 63 Hz |
| Maximum Input Power | 2800 VA |
| Nominal Input AC Voltage Options | 200 VAC / 230 VAC |
Protection and Isolation Features
| Parameter | Value |
|---|---|
| Overcurrent Protection (OCP) | Yes, programmable electronic shutdown or current limit |
| Overvoltage Protection (OVP) | Yes, programmable |
| Overtemperature Protection (OTP) | Yes, automatic thermal shutdown |
System, Interfaces and Connectivity
| Parameter | Value |
|---|---|
| Remote Sensing Terminals | Yes, rear-panel terminals |
| Command Language | SCPI (Standard Commands for Programmable Instruments) |
| Arbitrary Waveform Generation | Yes, built-in arbitrary waveform capability |
Physical and Environmental
| Parameter | Value |
|---|---|
| Rack Unit Height | 5U |
| Cooling Configuration | Forced air cooling with internal fan (rear exhaust) |
Regulatory and Compliance
| Parameter | Value |
|---|---|
| Recommended Calibration Interval | 1 year |
Programming Resolution
| Parameter | Value |
|---|---|
| AC Voltage Programming Resolution (Low Range) | 12.5 mV |
| AC Voltage Programming Resolution (High Range) | 25 mV |
| DC Voltage Programming Resolution (Low Range) | 12.5 mV |
| DC Voltage Programming Resolution (High Range) | 25 mV |
| Current Limit Programming Resolution | 4 mA |
Measurement Resolution
| Parameter | Value |
|---|---|
| RMS Voltage Measurement Resolution | 10 mV |
| RMS Current Measurement Resolution | 4 mA |
Harmonic Measurement
| Parameter | Value |
|---|---|
| Harmonic Frequency Range | 45 Hz - 1000 Hz |
| Harmonic Order Range | Up to 50th harmonic |
Input Power
| Parameter | Value |
|---|---|
| Maximum Input Current (100 VAC nominal input) | 32 A |
| Maximum Input Current (120 VAC nominal input) | 26 A |
| Maximum Input Current (200 VAC nominal input) | 16 A |
| Maximum Input Current (208 VAC nominal input) | 16 A |
| Maximum Input Current (230 VAC nominal input) | 15 A |
Output
| Parameter | Value |
|---|---|
| Output Coupling | AC, DC, AC+DC |
Applications
Power supply testing, UPS testing, avionics ATE, and power factor corrected equipment testing