The Keysight Agilent HP 6843A is a high-performance, single-phase programmable AC Power Source and Analyzer. Designed for rigorous testing, it combines the capabilities of a power amplifier, AC calibrator, and harmonic analyzer in a single cabinet. It is widely used for mains simulation, power compliance testing, and harmonic and flicker analysis.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB (IEEE-488), RS-232 |
| Display | Vacuum Fluorescent Display (VFD) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 200 V / 208 V / 230 V / 400 V AC (3-phase, configuration dependent), 47 to 63 Hz |
| Operating Temperature | 0 to 40 °C |
| Dimensions (W×H×D) | 426 mm × 222 mm × 641 mm |
| Weight | 63 kg |
AC Output Ratings
| Parameter | Value |
|---|---|
| Number of Phases | 1 (Single-Phase) |
| Maximum AC Output Power | 4800 VA |
| AC Voltage Ranges | 0 to 135 Vrms / 0 to 270 Vrms |
| Maximum AC RMS Current (135 V Range) | 36 A |
| Maximum AC RMS Current (270 V Range) | 18 A |
| Maximum AC Peak Current (135 V Range) | 180 A |
| Maximum AC Peak Current (270 V Range) | 90 A |
| Output Frequency Range | 45 Hz to 1000 Hz |
Output Accuracy & Resolution
| Parameter | Value |
|---|---|
| AC Voltage Programming Accuracy | ±(0.15% of output + 0.3 V) for 135 V range, ±(0.15% of output + 0.6 V) for 270 V range |
| Frequency Programming Accuracy | ±0.01% |
| Frequency Programming Resolution | 10 mHz (45 to 100 Hz), 100 mHz (100 to 1000 Hz) |
| AC Voltage Programming Resolution | 125 mV (135 V range) / 250 mV (270 V range) |
DC Output Ratings
| Parameter | Value |
|---|---|
| Maximum DC Output Power | 3200 W |
| DC Voltage Ranges | 0 to 190 VDC / 0 to 380 VDC |
Measurement Capabilities
| Parameter | Value |
|---|---|
| RMS Voltage Measurement Ranges | 0 to 135 Vrms / 0 to 270 Vrms |
| RMS Current Measurement Ranges | 4 A / 40 A |
| Measurement Functions | Voltage (RMS, DC, AC, Peak), Current (RMS, DC, AC, Peak), Power (Active, Reactive, Apparent), Power Factor, Crest Factor, Frequency, Harmonic Analysis |
| Harmonic Measurement Range | 1st to 50th harmonic |
| Harmonic Fundamental Frequency Range | 45 Hz to 75 Hz |
Output Distortion
| Parameter | Value |
|---|---|
| Total Harmonic Distortion (THD) of Output | < 1% (45 Hz to 400 Hz) |
Output Capabilities
| Parameter | Value |
|---|---|
| Waveform Generation Modes | Sine, Square, User-defined (Arbitrary) |
| Start Phase Programming Range | 0 to 360 degrees |
Remote Sensing
| Parameter | Value |
|---|---|
| Remote Sense Line Drop Compensation | Up to 2 V per load lead |
System Connectivity & Control
| Parameter | Value |
|---|---|
| Command Set | SCPI (Standard Commands for Programmable Instruments) |
Protection Features
| Parameter | Value |
|---|---|
| Over-Voltage Protection (OVP) | Programmable AC and DC limits |
| Over-Current Protection (OCP) | Programmable AC and DC limits |
| Over-Temperature Protection (OTP) | Automatic shutdown with error reporting |
DC Output Specifications
| Parameter | Value |
|---|---|
| DC Voltage Programming Accuracy | 0.1% + 0.5 V (135 V range) / 0.1% + 1.0 V (270 V range) |
| DC Voltage Programming Resolution | 125 mV (135 V range) / 250 mV (270 V range) |
Inputs & Outputs
| Parameter | Value |
|---|---|
| External Analog Input Bandwidth | DC to 5 kHz |
| External Analog Input Voltage Range | -10 V to +10 V |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -40 °C to +75 °C |
AC Input
| Parameter | Value |
|---|---|
| AC Input Phase | 3-phase |
| AC Input Frequency Range | 47 Hz - 63 Hz |
| AC Input Voltage Options | 174 - 220 Vac (Option 200) / 191 - 242 Vac (Option 208) / 207 - 254 Vac (Option 230) / 360 - 440 Vac (Option 400) / 414 - 508 Vac (Option 460) |
| Maximum Input Power | 7500 VA |
DC Output
| Parameter | Value |
|---|---|
| Maximum DC Output Current (135 V Range) | 26 A |
| Maximum DC Output Current (270 V Range) | 13 A |
Performance
| Parameter | Value |
|---|---|
| AC Voltage Line Regulation | 0.1 V |
| AC Voltage Load Regulation | 0.5 V |
| DC Voltage Line Regulation | 0.1 V |
| DC Voltage Load Regulation | 0.5 V |
| Transient Generation Modes | Step, Pulse, List |
Measurements
| Parameter | Value |
|---|---|
| Active Power Measurement Range | 0 - 4800 W |
| Apparent Power Measurement Range | 0 - 4800 VA |
| Power Factor Measurement Range | 0.00 - 1.00 |
Technology
Linear/Switching hybrid AC Source with DSP-based Analyzer
Applications
AC power simulation, harmonic testing, avionics power testing, and flicker analysis