The Keysight (Agilent) 8169A is a high-performance lightwave polarization controller designed for precise state of polarization (SOP) synthesis and control. Utilizing a fixed linear polarizer followed by independently motorized quarter-wave and half-wave plates, it enables accurate and repeatable polarization settings across the standard telecommunications bands. It is widely used for polarization-dependent loss (PDL) and polarization-mode dispersion (PMD) characterization in fiber-optic communications testing.

Specifications

General

ParameterValue
InterfacesGPIB (HP-IB)
DisplayLiquid Crystal Display (LCD)
Warm-up Time20 minutes

Physical

ParameterValue
Power Supply100 / 115 / 230 / 240 V AC (+10% / -15%), 48 to 66 Hz, 45 VA max
Operating Temperature0 to 55 °C
Dimensions (W×H×D)213 mm × 89 mm × 345 mm
Weight5.3 kg

Optical Specifications

ParameterValue
Operating Wavelength Range1475 nm to 1575 nm
Optional Wavelength Range (Option 021)1275 nm to 1375 nm
Insertion Loss< 1.2 dB (typically < 0.8 dB) including HMS-10 connectors
Insertion Loss Variation vs. Polarization State< ±0.03 dB
Maximum Input Optical Power+20 dBm (100 mW)
Return Loss> 40 dB (typically > 48 dB with HMS-10/HP connectors)
Polarization Extinction Ratio> 40 dB (after internal polarizer)
Fiber Type9/125 µm Single-mode

Polarization Control & Synthesis

ParameterValue
Polarization Control ElementsFixed linear polarizer, motorized quarter-wave plate, motorized half-wave plate
Quarter-Wave Plate Rotation Range0.0° to 360.0°
Half-Wave Plate Rotation Range0.0° to 360.0°
Programming Angular Resolution0.01°

Optical & Electrical Interfaces

ParameterValue
Optical Input InterfaceFlexible HMS-10 connector adapter system (FC/PC, SC, ST etc. compatible with options)
Optical Output InterfaceFlexible HMS-10 connector adapter system
Trigger Input LevelTTL compatible (BNC connector)
Trigger Output LevelTTL compatible (BNC connector)

System Control & Software

ParameterValue
Remote Control InterfaceGPIB (IEEE-488.1 and IEEE-488.2)
Command SetSCPI (Standard Commands for Programmable Instruments)

Environmental & Reliability

ParameterValue
Storage Temperature Range-40 °C to +70 °C
Operating Humidity LimitsUp to 95% R.H. non-condensing (0 °C to 40 °C)

Physical Characteristics

ParameterValue
Form FactorStandard HP System II 2U high cabinet (half width)

Power Requirements

ParameterValue
AC Input Voltage100 V / 115 V / 230 V / 240 V AC (+10% / -15%)
AC Input Frequency48 Hz to 66 Hz
Power Consumption45 VA max

Options

ParameterValue
Option 020Straight contact optical connector interface
Option 022Angled contact optical connector interface

Performance

ParameterValue
Angular Repeatability< ±0.02°
Angular Accuracy< ±0.1°
Sequence CapacityUp to 500 steps
Wavelength Setting Resolution0.1 nm

Inputs & Outputs

ParameterValue
Trigger ConnectorsBNC (female)

Connectivity

ParameterValue
GPIB CapabilitiesSH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0

Technology

Motorized Waveplates

Applications

Polarization Synthesis and Control