The Keysight (Agilent) 8482H is a high-power thermocouple RF power sensor designed for accurate average power measurements from 100 kHz to 4.2 GHz. Featuring an integrated 30 dB attenuator, it expands the measurement range up to +35 dBm (3 Watts) while maintaining low SWR to minimize mismatch uncertainty.

Specifications

General

ParameterValue
InterfacesProprietary 12-pin connector (requires Keysight 11730A series sensor cable)
DisplayNone (uses host power meter display)

Physical

ParameterValue
Power SupplyPowered by compatible host power meter via cable
Operating Temperature0 to 55 °C
Dimensions (W×H×D)38 mm × 30 mm × 174 mm
Weight0.5 kg
Shipping Weight1.1 kg (2.4 lb)

Measurement Ranges & Power Specifications

ParameterValue
Frequency Range Minimum100 kHz
Frequency Range Maximum4.2 GHz
Power Measurement Range Minimum-10 dBm
Power Measurement Range Maximum+35 dBm
Power Measurement Range (Watts)100 µW to 3 W
Maximum Continuous Input Power3.5 W (+35.4 dBm)
Maximum Peak Input Power100 W

Sensor Technology & Architecture

ParameterValue
Sensor Detection TypeThermocouple
Measurement Modes SupportedAverage Power
Dynamic Range45 dB
Attenuator Value30 dB (integrated)

RF Port Characteristics

ParameterValue
Input Impedance50 Ω
RF Connector TypeType-N
Connector SexMale
Maximum SWR (100 kHz to 300 kHz)1.60
Maximum SWR (300 kHz to 1.24 GHz)1.20
Maximum SWR (1.24 GHz to 4.2 GHz)1.30

Accuracy, Calibration & Noise

ParameterValue
Calibration TraceabilityUS National Institute of Standards and Technology (NIST)
Calibration Factor Storage TypePrinted table on sensor body for manual entry
Zero Set±50 µW
Zero Drift±10 µW (1 hour, constant temperature)
Measurement Noise±110 µW

Meter Compatibility & System Integration

ParameterValue
Compatible Power Meter ModelsEPM Series (E4418A/B, E4419A/B), EPM-P Series (E4416A, E4417A), P-Series (N1911A, N1912A), E1416A VXI, 70100A, 435A/B, 436A, 437A/B, 438A
Recommended Calibration Cycle1 Year

Environmental Parameters

ParameterValue
Storage Temperature Range-40 to +75 °C
Operating Humidity Range95% RH at 40 °C (non-condensing)
Maximum Operating Altitude4,600 meters (15,000 feet)

Regulatory Compliance

ParameterValue
EMC Standards ComplianceIEC 61326-1 / EN 55011 Class A
Safety Standards ComplianceIEC 61010-1

Performance

ParameterValue
Power Linearity (-10 to +20 dBm)Negligible
Power Linearity (+20 to +30 dBm)±3%
Power Linearity (+30 to +35 dBm)±10%

Calibration

ParameterValue
Reference Calibration Point50 MHz, 1.00 mW (0 dBm)

Connectivity

ParameterValue
Compatible Cable SeriesKeysight 11730 series
Power Meter Connector12-pin circular male

Design

ParameterValue
Attenuator IntegrationPermanently attached and individually calibrated 20 dB attenuator

Technology

Thermocouple

Applications

RF & Microwave Power Measurement