61 models with full specifications in Sensors.
This page summarizes Keysight (Agilent/HP) power and optical sensors in the RF, microwave, millimeter‑wave and optical domains and explains how the lineup is structured. It is written for engineers and technical buyers who must pick sensors by frequency coverage, power range, dynamic range, peak/pulse capability, connector type and host interface. The copy explains the main sensor families (USB standalone sensors, meter‑attached E‑ and P‑series modules, high‑power thermocouple sensors and waveguide/mmWave modules), the sensing technologies they use, and the practical tradeoffs that determine which model class fits an application.
- Representative frequency extremes
- 9 kHz (U2004A) to 110 GHz (W8486A)
- Lowest quoted sensitivity
- -70 dBm (E4412A / E4413A / 8484A / 8487D examples)
- High continuous power modules
- 0 to +44 dBm (8481B / 8482B high‑power sensors)
- Common host interfaces
- USB 2.0 for standalone sensors (U2001A/U2004A/U2000A) and meter sensor interfaces for E/P‑series
All models
| Model | Type | Operating Temperature | Interfaces | Power Supply |
|---|---|---|---|---|
| U2002A | *misc | 0 to 55 °C | USB 2.0 | USB bus powered (+5 VDC) |
| N1921A | Power Sensors | 0 °C to 55 °C | — | — |
| 8485D | Power Sensors | 0 to 55 °C | — | — |
| 8481A | Power Sensors | 0 to 55 °C | — | — |
| 478A | Power Sensors | — | — | — |
| 8485A | Power Sensors | 0 to 55 °C | — | — |
| E4413A | Power Sensors | 0 to 55 °C | — | — |
| E9300A | Power Sensors | 0 to +55 °C | E‑Series sensor interface to compatible power meters; no direct USB/LAN/GPIB (control via meter) | Powered from compatible power meter via E‑Series sensor interface (no external supply) |
| E9327A | Power Sensors | — | Meter sensor interface only; no direct USB/LAN/GPIB | — |
| U2049XA | Power Sensors | — | — | — |
| 11792A | Power Sensors | 0 to 55 °C | Multi-pin sensor cable connection to HP 8902A | Powered directly by the HP 8902A host receiver |
| 8481B | Power Sensors | 0 to 55 °C | None (analog connection to host power meter via standard 11730A cable) | Powered directly by the host power meter |
| 81635A | Power Sensors | — | None (controlled entirely via host mainframe GPIB, LAN, or USB) | Derived from host mainframe |
| 8483A | Power Sensors | 0 to 55 °C | Type-N (75 Ω) male input, proprietary multi-pin power meter sensor interface | Powered directly from the connected power meter |
| 8484A | Power Sensors | 0 to 55 °C | Proprietary multi-pin power sensor connector (compatible with HP 11730-series cables) | Powered by compatible power meter via sensor cable |
| E4412A | Power Sensors | 0 to 55 °C | Proprietary multi-pin connector (uses 11730A series sensor cables) | Powered directly from the host power meter |
| U2001A | *misc | 0 °C to 55 °C | USB 2.0 (USBTMC-USB488) | USB Bus Powered (4.75 V to 5.25 V) |
| V8486A | Power Sensors | 0 to 55 °C | Keysight/Agilent 8480-series multi-pin sensor cable interface; Type-N (male) connector for 50 MHz calibration port | Host-powered via compatible power meter |
| 8481D | Power Sensors | 0 to 55 °C | Proprietary multi-pin connector for power meter sensor cables | Supplied by connected power meter via sensor cable |
| 8481H | Power Sensors | 0 to 55 °C | — | — |
| 8482A | Power Sensors | 0 to 55 °C | — | Powered via sensor cable from connected power meter |
| 8487D | Power Sensors | 0 to 55 °C | Proprietary 12-pin multi-conductor cable interface | Powered by host power meter via sensor cable |
| U2000A | *misc | 0 to 55 °C | USB 2.0 (via proprietary 5-pin to USB-A cable) | — |
| U2001H | *misc | 0 to 55 °C | USB 2.0 (USBTMC-USB488) | — |
| 8482B | Power Sensors | 0 to 55 °C | Proprietary 12-pin multi-contact connector (compatible with Keysight 11730 series cables) | Supplied by host power meter via sensor cable |
| E9301A | Power Sensors | 0 to 55 °C | Proprietary power sensor cable interface | Powered from host power meter |
| E9304A | Power Sensors | 0 to 55 °C | Proprietary system interface connector to compatible power meter | Powered by compatible power meter |
| E9322A | Power Sensors | 0 to 55 °C | Proprietary multi-pin connector for E-series power meters | Powered via sensor cable from connected power meter |
| N1922A | Power Sensors | 0 to 55 °C | Proprietary multi-pin sensor cable interface to P-Series power meters | Powered directly by compatible P-Series power meter via sensor cable |
| U2004A | *misc | 0 to 55 °C | USB 2.0 High Speed (USBTMC-USB488) | USB bus powered, 4.5 V to 5.5 V, < 200 mA (measurement), < 275 mA (zeroing/calibration) |
| 81536A | Optical | 0 to 55 °C | Internal mainframe interface (GPIB and RS-232 available via host mainframe) | Powered directly by host mainframe |
| 81630B | Power Sensors | 0 °C to +40 °C | None on module (uses host mainframe interfaces: GPIB, LAN, USB, RS-232) | Powered directly by host mainframe slot |
| E9325A | Power Sensors | 0 to 55 °C | Proprietary sensor cable interface to host power meter | Powered by host power meter via sensor cable |
| N8486AR | Power Sensors | 0 to 55 °C | 12-pin male connector (sensor cable port), BNC female (calibration input) | Supplied by compatible Keysight power meter |
| Q8486A | Power Sensors | 0 to 55 °C | — | Powered by host power meter |
| R8486D | Power Sensors | 0 to 55 °C | UG-599/U waveguide flange, Type-N (male) 50 MHz calibration port, 12-pin sensor cable connector | Powered by compatible power meter via sensor cable |
| U8488A | Power Sensors | 0 to 55 °C | USB 2.0 (USBTMC compliant) | USB Bus Powered (5 V, < 500 mA) |
| W8486A | Power Sensors | 0 to 55 °C | Proprietary 12-pin connector for sensor cable | Powered by compatible power meter via sensor cable |
| 81633A | Power Sensors | 0 °C to 40 °C | Mainframe proprietary slot interface; Front-panel BNC analog output | Powered directly via mainframe slot |
| 81636B | Power Sensors | 0 °C to 40 °C | None (uses host mainframe backplane interface) | Powered internally by the host mainframe slot |
| 84814A | Power Sensors | 0 to 55 °C | Specialized multi-pin cable for connection to HP 8990A/8991A peak power analyzers | Power supplied by host peak power analyzer |
| 8482H | Power Sensors | 0 to 55 °C | Proprietary 12-pin connector (requires Keysight 11730A series sensor cable) | Powered by compatible host power meter via cable |
| 8487A | Power Sensors | 0 to 55 °C | None (connects to power meter via proprietary cable) | Powered by connected power meter |
| E9300B | Power Sensors | 0 to 55 °C | Proprietary cable interface for connection to compatible power meters | Powered directly from connected power meter host |
| E9300H | Power Sensors | 0 to 55 °C | Bulkhead connector for E9288 series sensor cables | Powered directly from the host power meter via sensor cable |
| E9323A | Power Sensors | 0 to 55 °C | Proprietary sensor interface cable; GPIB/LAN/USB (dependent on host power meter) | Power supplied by host power meter via sensor cable |
| N1923A | Power Sensors | 0 to 55 °C | Integrated P-Series sensor cable (3.0 m) | Powered directly from the host P-Series power meter |
| R8486A | Power Sensors | 0 to 55 °C | Proprietary 12-pin connector (for connection to power meter via sensor cable) | Powered directly by the connected power meter via sensor cable |
Looking for Keysight Technologies (Agilent HP) Sensors?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us
How the Keysight sensor range is organised
Keysight's sensors fall into clear classes by how they are hosted and by frequency/power focus:
-
USB standalone sensors: Compact, PC‑controlled modules that do not require a separate power‑meter mainframe. Example models include U2001A (10 MHz–6 GHz), U2004A (9 kHz–6 GHz) and U2000A (10 MHz–18 GHz). Several USB sensors are bus powered.
-
Meter‑attached E‑series and P‑series sensors: These plug into Keysight power meters and mainframes. E‑series examples such as E9300A/E9301A/E9304A and E9327A provide true average or peak/average functions and rely on the host for power and display. P‑series sensors (for example N1921A, N1922A) target wideband and peak/average plus high video bandwidth measurements for pulsed and complex signals.
-
High‑power thermocouple/attenuator sensors: Models such as 8481B and 8482B integrate attenuators and thermocouple elements to measure up to the +44 dBm class of average power.
-
Waveguide and mmWave sensors: For banded waveguide work, Keysight offers dedicated modules (for example V8486A, Q8486A, N8486AR, R8486D, W8486A) that present a waveguide flange and calibration port suited to their band.
Sensor technologies and tradeoffs
Two sensing technologies dominate the RF/microwave lineup and each has tradeoffs:
-
Diode sensors: Found in many E‑ and USB‑connected models (examples: E4412A, E4413A, 8484A, 8487D). Diode sensors reach the lowest detectable powers in the product set (−70 dBm is quoted on several diode models) and generally offer wide dynamic range. They are typically used where low‑level average or peak detection is required.
-
Thermocouple/thermistor sensors: Used where high continuous power or integrated attenuation is required. Examples include 8481B and 8482B which are positioned for measurement of milliwatt to multiwatt average power levels (0 to +44 dBm quoted on those models). Thermocouple sensors tolerate higher input and often have integrated attenuators for high‑power applications.
Waveguide and banded thermocouple/diode sensors (V8486A, N8486AR, Q8486A, R8486D, W8486A) trade connector format and band‑specific SWR for banded waveguide coupling and calibration features appropriate to millimeter‑wave work. Optical sensor modules (for lightwave mainframes, e.g. 81630B) use InGaAs detectors and are specified by wavelength and optical power range rather than RF power.
Peak, pulse and timing considerations
If you need peak or time‑gated measurements, examine video bandwidth and rise/fall times or explicit peak modes:
-
P‑series examples N1921A and N1922A specify wide video bandwidth (N1921A: video bandwidth ≤ 30 MHz; N1922A: 30 MHz VBW) and fast rise/fall times (N1921A rise/fall ≤ 13 ns) to support peak and short‑pulse analysis.
-
USB and E‑series peak sensors are also available. The U2021XA (USB peak/average) lists a 30 MHz video bandwidth and ≤13 ns rise/fall, while meter‑attached peak/average sensors like E9327A expose time‑gated peak/average capability when used with compatible meters (E9327A: video bandwidth up to 5 MHz for gated measurements).
Check the sensor's maximum peak and continuous average ratings before applying pulses: sensors list both maximum continuous average power and maximum allowed pulse/peak power or damage levels.
Interfaces, calibration and practical selection tips
Choose a sensor class by how you plan to integrate it:
-
USB standalone sensors (U2001A, U2004A, U2000A, U2002A, U2001H, U8487A, U8488A) connect directly to a PC or compatible Keysight host via USB 2.0 (USBTMC/USBTMC‑USB488 in many models) and in numerous models are bus powered. They are convenient for bench and automated PC‑based test where a separate power‑meter mainframe is not required.
-
E‑series and P‑series sensors rely on a host power meter (EPM, EPM‑P, P‑series and compatible mainframes listed in each sensor's notes) for power, control and display. They are suited to lab test racks and where multiple sensor types are used under a single meter.
-
Calibration and stability: many Keysight sensors specify a recommended calibration interval of 1 year; some sensors include onboard EEPROM to store calibration factors (for example E4412A/E4413A/E4412‑class sensors and others note EEPROM storage).
Practical checklist: match required frequency band and connector type, verify the power range and damage limits for your signals, confirm peak/video bandwidth when pulse timing matters, and select the host interface (USB vs meter) that fits your automation and display needs.
Popular models
Frequently asked questions
- When should I choose a USB sensor versus a meter‑attached sensor?
- USB sensors simplify bench and PC‑based measurements because they connect directly to a host and often draw bus power. Meter‑attached sensors are intended for use with Keysight power‑meter mainframes and are a better fit when you need a centralized display, rack integration, or to mix multiple sensor types on one meter.
- Which sensor class is best for pulsed or peak measurements?
- Use sensors that specify video bandwidth and rise/fall times or that explicitly support peak/time‑gated modes. P‑series and some E‑series/USB peak sensors are designed for that work; check the sensor's VBW or rise/fall specification and its maximum peak rating before use.
- How do I pick a waveguide or mmWave sensor?
- Select a sensor with the correct waveguide band and a built‑in calibration port or flange for your setup. Waveguide sensors are banded devices (WR‑15, WR‑10, WR‑22, etc.), so choose the module that matches your frequency band and connector format.