The Keysight E3620A is a compact, dual-output 50W linear bench power supply featuring two independent, isolated outputs. It provides clean, low-noise DC power with excellent load and line regulation, precise ten-turn potentiometers, and digital LED displays, making it an excellent choice for general-purpose benchtop testing.

Specifications

General

ParameterValue
InterfacesNone (analog manual control only)
Product SeriesE3600 Series
Installation CategoryInstallation Category II
Pollution DegreePollution Degree 2

Physical

ParameterValue
Operating Temperature0 to 55 °C (current derated 3.3% per °C from 40°C to 55°C)
Dimensions (W×H×D)212.8 mm W × 88.1 mm H × 348.3 mm D
Weight5.5 kg
Shipping Weight6.7 kg

DC Output Specifications

ParameterValue
Number of Outputs2 (independent and isolated)
Output Channel 1 Voltage Range0 to 25 V
Output Channel 1 Current Range0 to 1 A
Output Channel 2 Voltage Range0 to 25 V
Output Channel 2 Current Range0 to 1 A
Total Maximum Power50 W
Output Isolation Voltage240 Vdc (each output can be floated up to 240 V from chassis ground)
Series-Parallel Mode CapabilityOutputs can be connected in series or parallel

Regulation

ParameterValue
Voltage Load Regulation< 0.01% + 2 mV
Voltage Line Regulation< 0.01% + 2 mV

Ripple & Noise

ParameterValue
Voltage Ripple and Noise (RMS)< 350 µV
Voltage Ripple and Noise (Peak-to-Peak)< 1.5 mV
Common Mode Current Ripple (RMS)< 1.0 µA

Meter Accuracy

ParameterValue
Voltage Meter Accuracy (at 25°C ± 5°C)±(0.5% of output + 2 counts)
Current Meter Accuracy (at 25°C ± 5°C)±(0.5% of output + 2 counts)

Meter Resolution

ParameterValue
Voltage Meter Resolution (0 - 20 V)10 mV
Voltage Meter Resolution (> 20 V)100 mV
Current Meter Resolution1 mA

Performance

ParameterValue
Transient Response Recovery Time< 50 µs (for output recovery to within 15 mV after a 50% to 100% load change)
Output Voltage Temperature Coefficient< 0.02% + 1 mV per °C

Protection Features

ParameterValue
Overload ProtectionFront-panel LED overload indicators (activate when output current exceeds limit)
Short-Circuit ProtectionContinuous current limiting

Control & Interface

ParameterValue
Voltage Control MechanismTen-turn potentiometers for precise voltage adjustment

Environmental

ParameterValue
Cooling MechanismConvection cooling (silent, fanless operation)

Power

ParameterValue
AC Input Frequency Range47 Hz - 63 Hz

Technology

Linear

Applications

Benchtop electronic testing and prototyping