The Keysight (Agilent) E3649A is a high-performance, dual-output, 97W programmable DC power supply designed for both benchtop use and system integration. Part of the popular E3640 series, it provides clean, low-ripple power with dual output ranges up to 35V/1.4A or 60V/0.8A per channel. Complete with GPIB and RS-232 interfaces, it features Standard Commands for Programmable Instruments (SCPI) support, excellent regulation, and dual-line vacuum fluorescent displays, making it ideal for general-purpose electronic test and R&D environments.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB, RS-232 |
| Display | Vacuum fluorescent display (VFD), dual line |
Output Specifications
| Parameter | Value |
|---|---|
| Number of Outputs | 2 |
| Output Voltage Range (Range 1) | 0 to 35 V |
| Output Current Range (Range 1) | 0 to 1.4 A |
| Output Voltage Range (Range 2) | 0 to 60 V |
| Output Current Range (Range 2) | 0 to 0.8 A |
| Maximum Power Rating | 97 W |
| Load Regulation (Voltage) | < 0.01% + 3 mV |
| Load Regulation (Current) | < 0.01% + 250 µA |
| Line Regulation (Voltage) | < 0.01% + 3 mV |
| Line Regulation (Current) | < 0.01% + 250 µA |
| Normal Mode Voltage Ripple & Noise (rms) | < 1 mVrms |
| Normal Mode Voltage Ripple & Noise (peak-to-peak) | < 8 mVpp |
| Normal Mode Current Ripple & Noise (rms) | < 4 mArms |
| Common Mode Noise Current | < 1.5 µArms |
Programming Accuracy
| Parameter | Value |
|---|---|
| Voltage Programming Accuracy (Output 1) | < 0.05% + 10 mV |
| Voltage Programming Accuracy (Output 2) | < 0.05% + 10 mV |
| Current Programming Accuracy (Outputs 1 & 2) | < 0.2% + 10 mA |
Readback Accuracy
| Parameter | Value |
|---|---|
| Voltage Readback Accuracy (Output 1) | < 0.05% + 5 mV |
| Voltage Readback Accuracy (Output 2) | < 0.05% + 5 mV |
| Current Readback Accuracy (Output 1) | < 0.15% + 5 mA |
| Current Readback Accuracy (Output 2) | < 0.15% + 5 mA |
Transient Response and Settling
| Parameter | Value |
|---|---|
| Transient Response Recovery Time | < 50 µs |
| Transient Response Settling Band | within 15 mV of final value following a 50% to 100% or 100% to 50% load change |
Protection Features
| Parameter | Value |
|---|---|
| Overvoltage Protection (OVP) Accuracy | < 0.5% + 0.5 V |
Isolation and Connections
| Parameter | Value |
|---|---|
| Maximum Isolation Voltage (Output to Ground) | 240 Vdc |
| Remote Sensing Capability | Up to 1 V drop per lead |
System Control and Interface
| Parameter | Value |
|---|---|
| Command Language / Syntax Standards | SCPI (Standard Commands for Programmable Instruments) |
| Save/Recall State Storage Capacity | 5 states |
Environmental Specifications
| Parameter | Value |
|---|---|
| Storage Temperature Range | -20 to 70 °C |
| Relative Humidity (Non-condensing) | Up to 80% RH at 40°C |
| Cooling System Type | Fan-cooled |
Physical Characteristics
| Parameter | Value |
|---|---|
| Net Weight | 9.2 kg |
| Rack Mounting Unit (RU) Height | 3U (half-rack width) |
Compliance and Standards
| Parameter | Value |
|---|---|
| Safety Standards Certifications | Certified to CSA 22.2 No. 1010.1, IEC 1010-1 / EN 61010-1 |
| Electromagnetic Compatibility (EMC) Compliance | EN 55011 Group 1 Class A, EN 50082-1 |
Power Requirements
| Parameter | Value |
|---|---|
| AC Input Frequency | 47 Hz to 63 Hz |
Performance
| Parameter | Value |
|---|---|
| Maximum Sense Lead Compensation Voltage | 1 V per lead |
| Warm-up Time | 30 minutes |
Environmental
| Parameter | Value |
|---|---|
| Operating Altitude | Up to 2000 meters |
Compliance & Safety
| Parameter | Value |
|---|---|
| Installation Category | IEC 1010-1 Overvoltage Category II |
| Pollution Degree | Pollution Degree 2 |
Maintenance
| Parameter | Value |
|---|---|
| Recommended Calibration Interval | 1 year |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Rear Panel Connections | Screw-terminal blocks for Output 1 and Output 2 (including remote sense), GPIB (IEEE-488) connector, RS-232 (9-pin female) connector |
Interfaces & Control
| Parameter | Value |
|---|---|
| Default GPIB Address | 5 |
| RS-232 Baud Rates | 300, 600, 1200, 2400, 4800, 9600 baud |
| RS-232 Flow Control | DTR/DSR (hardware) or None |
| SCPI Compliance Version | 1997.0 |
Technology
Linear power supply
Applications
Test and Measurement, R&D Benchtop, and Automated Test Systems (ATE)