The Keysight (Agilent) E9301A is an E-series average power sensor designed for measuring RF and microwave power across a wide dynamic range, regardless of signal modulation. Operating from 10 MHz to 6 GHz, it utilizes a patented diode-attenuator-diode topology to ensure high measurement accuracy, low standing-wave-ratio (SWR), and low harmonic generation. Calibration factors, linearity, and temperature compensation data are stored internally in its EEPROM, simplifying setup when used with compatible Keysight/Agilent EPM, EPM-P, and P-series power meters.

Specifications

General

ParameterValue
InterfacesProprietary power sensor cable interface
Recommended Calibration Cycle1 year

Physical

ParameterValue
Power SupplyPowered from host power meter
Operating Temperature0 to 55 °C
Dimensions (W×H×D)38 mm × 30 mm × 150 mm
Weight0.18 kg

RF Performance

ParameterValue
Frequency Range10 MHz to 6 GHz
Power Measurement Range-60 dBm to +20 dBm
Dynamic Range80 dB
Maximum Continuous Power (CW)+25 dBm (average)
Maximum Peak Power+33 dBm (< 10 µs duration)
RF Input ConnectorType-N (male)
Nominal Impedance50 Ω
SWR (10 MHz to 30 MHz)1.15
SWR (30 MHz to 2 GHz)1.13
SWR (2 GHz to 6 GHz)1.19

Measurement Accuracy & Linearity

ParameterValue
Measurement TopologyPatented diode-attenuator-diode
Measurement PathsDual-path (Low power: -60 to -10 dBm; High power: -10 to +20 dBm) with fast automatic switching
EEPROM StorageCalibration factors, linearity, and temperature compensation data stored in internal EEPROM
Modulation IndependenceBandwidth independent; measures average power of all modulation formats

Speed & Sampling

ParameterValue
Measurement SpeedUp to 400 readings per second (with Agilent E4416A)

System Compatibility

ParameterValue
Compatible Power MetersAgilent EPM (E4418, E4419), EPM-P (E4416A), and P-series power meters

Environmental

ParameterValue
Storage Temperature Range-55 to +75 °C
Operating HumidityUp to 95% RH at 40 °C (non-condensing)
Operating AltitudeUp to 4,600 m (15,000 ft)
Storage AltitudeUp to 15,240 m (50,000 ft)
Vibration StandardMIL-PRF-28800F Class 3
Shock StandardMIL-PRF-28800F Class 3

Accuracy

ParameterValue
Power Linearity (15 to 35 °C)±3.0%
Power Linearity (0 to 55 °C)±4.0%
Calibration Factor Uncertainty (10 to 30 MHz)±1.8% (15 to 35 °C)
Calibration Factor Uncertainty (30 to 500 MHz)±1.6% (15 to 35 °C)
Calibration Factor Uncertainty (500 MHz to 1.2 GHz)±1.8% (15 to 35 °C)
Calibration Factor Uncertainty (1.2 to 6 GHz)±1.7% (1.2 to 2 GHz), ±1.8% (2 to 6 GHz)

Connectivity

ParameterValue
Compatible Sensor CablesE9288A (1.5 m), E9288B (3 m), E9288C (10 m)

Accuracy & Performance

ParameterValue
Zero Set (Path A)±115 pW
Zero Set (Path B)±300 nW
Zero Drift (Path A)±50 pW
Zero Drift (Path B)±100 nW
Measurement Noise (Path A)±110 pW
Measurement Noise (Path B)< 110 nW

Compliance

ParameterValue
EMC StandardsIEC 61326-1 / EN 61326-1, CISPR 11 / EN 55011

Technology

Diode-attenuator-diode average power sensor

Applications

RF and microwave average power measurements for all modulation formats