The Keysight (Agilent) E9301B is an E-Series average power sensor designed for measuring average power across a wide dynamic range from -30 to +44 dBm over a frequency range of 10 MHz to 6 GHz. Utilizing a patented diode-attenuator-diode topology, the E9301B ensures accurate and repeatable average power measurements regardless of modulation format, making it ideal for wireless communication applications.

Specifications

Physical

ParameterValue
Power SupplyPowered by compatible power meter via sensor cable
Operating Temperature0 to 55 °C
Dimensions (W×H×D)52 mm × 50 mm × 214 mm
Weight0.275 kg

Measurement Ranges & Power Specifications

ParameterValue
Frequency Range Minimum10 MHz
Frequency Range Maximum6 GHz
Power Measurement Range Minimum-30 dBm
Power Measurement Range Maximum+44 dBm
Dynamic Range74 dB

Sensor Technology & Architecture

ParameterValue
Sensor Detection TypeDiode-attenuator-diode
Measurement Modes SupportedAverage power
Modulation IndependenceBandwidth independent, measures average power of all modulation formats

RF Port Characteristics

ParameterValue
Input Impedance50 Ω
RF Connector TypeType-N
Connector SexMale
Maximum SWR1.15

Accuracy, Calibration & Noise

ParameterValue
Calibration Factor Storage TypeInternal EEPROM
Stored Calibration DataCalibration factors, linearity, and temperature compensation

Meter Compatibility & System Integration

ParameterValue
Compatible Power Meter ModelsKeysight/Agilent EPM (including E4418, E4419), EPM-P, and P-series

Power Handling

ParameterValue
Maximum Continuous Input Power+45 dBm (at 0 to 35 °C), +43 dBm (at 35 to 55 °C)
Maximum Peak Input Power100 W (for < 10 µs at 0 to 35 °C), 60 W (for < 10 µs at 35 to 55 °C)

Environmental

ParameterValue
Storage Temperature Range-40 °C to +75 °C
Operating HumidityUp to 95% RH at 40 °C (non-condensing)
Storage HumidityUp to 90% RH at 65 °C (non-condensing)
Operating AltitudeUp to 4600 m (15,000 ft)

Accessories

ParameterValue
Compatible CablesE9288A, E9288B, E9288C

RF Characteristics

ParameterValue
Integrated Attenuator30 dB
Calibration Factor Uncertainty (10 MHz to 30 MHz)1.6% (at 25 °C ± 5 °C) / 2.4% (0 to 55 °C)
Calibration Factor Uncertainty (30 MHz to 2 GHz)1.4% (at 25 °C ± 5 °C) / 2.0% (0 to 55 °C)
Calibration Factor Uncertainty (2 GHz to 6 GHz)1.7% (at 25 °C ± 5 °C) / 2.3% (0 to 55 °C)

Linearity

ParameterValue
Power Linearity (-30 to -10 dBm)±3.0% (at 25 °C ± 5 °C) / ±3.5% (0 to 55 °C)
Power Linearity (-10 to 0 dBm)±2.5% (at 25 °C ± 5 °C) / ±3.0% (0 to 55 °C)
Power Linearity (0 to +10 dBm)±2.0% (at 25 °C ± 5 °C) / ±2.5% (0 to 55 °C)
Power Linearity (+10 to +30 dBm)±2.0% (at 25 °C ± 5 °C) / ±2.5% (0 to 55 °C)
Power Linearity (+30 to +44 dBm)±2.5% (at 25 °C ± 5 °C) / ±3.0% (0 to 55 °C)

Measurement Performance

ParameterValue
Zero Set (Range 1)500 nW
Zero Set (Range 2)1.5 µW
Measurement Noise (Range 1)700 nW (with 128 averages)
Measurement Noise (Range 2)2.1 µW (with 128 averages)
Zero Drift (Range 1)150 nW (over 1 hour at constant temperature)
Zero Drift (Range 2)150 µW

Technology

Diode-Attenuator-Diode

Applications

RF and Microwave Average Power Measurement