The Keysight N1923A is a P-Series wideband power sensor operating from 50 MHz to 18 GHz. Featuring an integrated 3.0-meter (10 ft) cable, it is designed for use with Keysight N1911A and N1912A P-Series power meters to perform high-speed peak, average, and time-gated power measurements. The sensor supports internal zeroing and calibration to eliminate the need for an external reference source.

Specifications

General

ParameterValue
InterfacesIntegrated P-Series sensor cable (3.0 m)

Physical

ParameterValue
Power SupplyPowered directly from the host P-Series power meter
Operating Temperature0 to 55 °C
Dimensions (W×H×D)40 mm × 27 mm × 135 mm
Weight0.226
Cable ConfigurationFixed/integrated cable

Measurement Ranges & Power Specifications

ParameterValue
Frequency Range50 MHz to 18 GHz
Power Measurement Range (Average Mode)-35 dBm to +20 dBm
Power Measurement Range (Normal Mode)-35 dBm to +20 dBm
Maximum Continuous Input Power+23 dBm (200 mW)
Maximum Peak Input Power+30 dBm (1 W) for < 10 µs duration
Maximum DC Input Voltage5 VDC

Sensor Technology & Architecture

ParameterValue
Sensor Detection TypeDiode-based
Measurement Modes SupportedNormal (Peak, Average, Time-gated, Rise/Fall time, Pulse width) and Average-only
Video Bandwidth≥ 30 MHz
Rise Time≤ 13 ns (for power levels > -15 dBm)
Fall Time≤ 13 ns (for power levels > -15 dBm)
Minimum Pulse Width50 ns

RF Port Characteristics

ParameterValue
Input Impedance50 Ω nominal
RF Connector TypeType-N
Connector SexMale
Maximum SWR (50 MHz to 2 GHz)1.12
Maximum SWR (2 GHz to 10 GHz)1.16
Maximum SWR (10 GHz to 16 GHz)1.21
Maximum SWR (16 GHz to 18 GHz)1.29

Triggering & Sampling

ParameterValue
Maximum Sampling Rate100 MSamples/s continuous sampling
Trigger Delay Range-1.0 s to +1.0 s
Time Resolution100 ps

Meter Compatibility & System Integration

ParameterValue
Compatible Power MetersKeysight N1911A (Single Channel) and N1912A (Dual Channel) P-Series Power Meters
Calibration Factor Storage TypeInternal EEPROM
Internal Calibration SupportYes (Internal Zero and Calibration, no external reference needed)

Environmental Parameters

ParameterValue
Storage Temperature Range-40 °C to +70 °C
Operating Humidity Range95% RH at 40 °C (non-condensing)
Storage Humidity Range90% RH at 65 °C (non-condensing)
Maximum Operating Altitude4,600 meters (15,000 feet)
Maximum Storage Altitude15,000 meters (50,000 feet)

Physical Dimensions & Weight

ParameterValue
Cable Length3.0 meters (10 feet)

Accuracy & Calibration

ParameterValue
Zero Set (Average Mode)±0.17 µW
Zero Set (Normal Mode)±1.4 µW
Zero Drift (Average Mode)±0.035 µW
Zero Drift (Normal Mode)±0.15 µW

Performance

ParameterValue
Measurement Noise (Average Mode)≤ 240 nW
Measurement Noise (Normal Mode)≤ 1.6 µW
Video Bandwidth SettingsHigh (30 MHz), Medium (15 MHz), Low (5 MHz), Off (300 kHz)
System Rise Time≤ 13 ns (with N1911A/N1912A)
System Fall Time≤ 13 ns (with N1911A/N1912A)
Trigger Jitter1 ns rms
Power Linearity (Normal Mode, -32 to -20 dBm)±4.5% (Normal Mode, -35 to -20 dBm)
Power Linearity (Normal Mode, -20 to +20 dBm)±4.0%
Power Linearity (Average Mode, -35 to -20 dBm)±4.5%
Power Linearity (Average Mode, -20 to +20 dBm)±4.0%

Triggering

ParameterValue
Internal Trigger Level Range-20 dBm to +20 dBm

Calibration

ParameterValue
Internal Zero and Cal SupportYes, without disconnecting RF input (internal RF switch)
Zeroing Time11 s (typical)
Calibration Time19 s (typical)

Inputs & Outputs

ParameterValue
Connector to Power MeterP-Series multi-pin sensor connector

EMC & Safety

ParameterValue
EMC ComplianceIEC 61326-1 / EN 61326-1, CISPR 11 / EN 55011 Class A
Safety ComplianceIEC 61010-1 / EN 61010-1

Technology

Diode-based wideband power sensor

Applications

RF and microwave pulse profiling, peak and average power measurements