The Keysight N3305A is a 500-watt DC electronic load module designed for use with the N3300A or N3301A mainframes. Operating with high accuracy and speed, it supports constant current, constant voltage, and constant resistance modes, making it ideal for testing power supplies, batteries, and power components. Occupying two slots in the mainframe, it handles up to 150 V and up to 60 A.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB, RS-232, 14-pin analog port (via N3300A/N3301A mainframe and rear connector) |
| Display | None (status indicators only; uses mainframe front panel display) |
| Maximum Input Isolation Voltage | 150 VDC (input to chassis ground) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | Powered by N3300A/N3301A mainframe backplane |
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 115.5 mm x 172 mm x 461 mm |
| Mainframe Slot Occupancy | 2 slots |
Input Ratings
| Parameter | Value |
|---|---|
| Maximum Input Power | 500 W |
| Maximum Input Current | 60 A |
| Maximum Input Voltage | 150 V |
| Minimum Operating Voltage at Full Scale Current | 1.2 V @ 60 A |
Operating Ranges
| Parameter | Value |
|---|---|
| Constant Current Low Range | 0 to 6 A |
| Constant Current High Range | 0 to 60 A |
| Constant Voltage Low Range | 0 to 15 V |
| Constant Voltage High Range | 0 to 150 V |
Programming Accuracy
| Parameter | Value |
|---|---|
| Constant Current Programming Accuracy (Low Range) | ±(0.1% + 7.5 mA) |
| Constant Current Programming Accuracy (High Range) | ±(0.1% + 15 mA) |
| Constant Voltage Programming Accuracy (Low Range) | ±(0.05% + 10 mV) |
| Constant Voltage Programming Accuracy (High Range) | ±(0.05% + 40 mV) |
Programming Resolution
| Parameter | Value |
|---|---|
| Constant Current Programming Resolution (Low Range) | 1.5 mA |
| Constant Current Programming Resolution (High Range) | 15 mA |
| Constant Voltage Programming Resolution (Low Range) | 3.75 mV |
| Constant Voltage Programming Resolution (High Range) | 37.5 mV |
Readback Accuracy
| Parameter | Value |
|---|---|
| Current Readback Accuracy (Low Range) | ±(0.08% + 6.5 mA) |
| Current Readback Accuracy (High Range) | ±(0.08% + 15 mA) |
| Voltage Readback Accuracy (Low Range) | ±(0.05% + 10 mV) |
| Voltage Readback Accuracy (High Range) | ±(0.05% + 35 mV) |
Readback Resolution
| Parameter | Value |
|---|---|
| Current Readback Resolution (Low Range) | 0.18 mA |
| Current Readback Resolution (High Range) | 1.8 mA |
| Voltage Readback Resolution (Low Range) | 0.45 mV |
| Voltage Readback Resolution (High Range) | 4.5 mV |
Transient & Dynamic
| Parameter | Value |
|---|---|
| Transient Frequency Range | 0.25 Hz to 10 kHz |
| Transient Duty Cycle Range | 3% to 97% (resolution 1%) |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to 75 °C |
Constant Resistance
| Parameter | Value |
|---|---|
| Constant Resistance Range 1 | 0.083 Ω to 2 Ω |
| Constant Resistance Range 2 | 1.5 Ω to 200 Ω |
| Constant Resistance Range 3 | 150 Ω to 10,000 Ω |
Ripple and Noise
| Parameter | Value |
|---|---|
| Current Ripple and Noise (rms) | 6 mA |
| Current Ripple and Noise (peak-to-peak) | 60 mA |
Transient Slew Rate
| Parameter | Value |
|---|---|
| Constant Current Slew Rate (Low Range) | 2.6 mA/µs to 260 mA/µs |
| Constant Current Slew Rate (High Range) | 26 mA/µs to 2.6 A/µs |
| Constant Current Slew Rate Programming Resolution (Low Range) | 1.05 mA/µs |
| Constant Current Slew Rate Programming Resolution (High Range) | 10.5 mA/µs |
Analog Monitoring
| Parameter | Value |
|---|---|
| Analog Current Monitor Output Range | 0 to 10 V |
| Analog Voltage Monitor Output Range | 0 to 10 V |
| Analog Current Monitor Accuracy | ±(1.5% of full scale + 10 mV) |
| Analog Voltage Monitor Accuracy | ±(1% of full scale + 10 mV) |
Sensing
| Parameter | Value |
|---|---|
| Maximum Voltage Drop per Load Lead | 2 V |
Constant Resistance Mode
| Parameter | Value |
|---|---|
| Constant Resistance Range 1 Programming Accuracy | ±(1% + 8 mS) with ≥ 6 A input |
| Constant Resistance Range 2 Programming Accuracy | ±(1% + 120 µS) with ≥ 0.6 A input |
| Constant Resistance Range 3 Programming Accuracy | ±(1% + 15 µS) with ≥ 0.06 A input |
Protection
| Parameter | Value |
|---|---|
| Overvoltage Protection Threshold | 170 V (nominal) |
| Overcurrent Protection Threshold (Low Range) | 6.5 A (nominal) |
| Overcurrent Protection Threshold (High Range) | 65 A (nominal) |
| Overpower Protection Threshold | 520 W (nominal) |
| Overtemperature Protection | Yes |
| Maximum Reverse Current (Diode Clamp) | 60 A |
Input Characteristics
| Parameter | Value |
|---|---|
| Input Resistance (With Input Off) | 20 kΩ (typical) |
Temperature Coefficient
| Parameter | Value |
|---|---|
| Voltage Temperature Coefficient | 0.005% + 1.5 mV per °C |
| Current Temperature Coefficient (Low Range) | 0.01% + 0.12 mA per °C |
| Current Temperature Coefficient (High Range) | 0.01% + 1.2 mA per °C |
Stability
| Parameter | Value |
|---|---|
| Voltage 8-Hour Drift | 0.012% + 1.5 mV |
| Current 8-Hour Drift (Low Range) | 0.03% + 1 mA |
| Current 8-Hour Drift (High Range) | 0.03% + 10 mA |
Compliance & Certifications
| Parameter | Value |
|---|---|
| Safety Compliance Standards | IEC 61010-1, EN 61010-1, CSA C22.2 No. 1010.1, UL 3111-1 |
| EMC Compliance Standards | EN 55011, CISPR 11 (Group 1, Class A), EN 50082-1 |
Maintenance
| Parameter | Value |
|---|---|
| Recommended Calibration Interval | 12 months |
Technology
DC Electronic Load
Applications
Power supply testing, battery testing, power component evaluation