The Keysight N6705A DC Power Analyzer Mainframe is a highly integrated, 4-slot modular instrument that combines up to four advanced DC power supplies, a digital multimeter, oscilloscope, arbitrary waveform generator, and data logger into a single compact benchtop solution. Designed to dramatically improve R&D productivity, it eliminates the need for external transducers or complex multi-instrument cabling. Fully programmable and LXI Class C compliant, it features dedicated front-panel controls, color-coded terminals, and a large color display for seamless sourcing and analysis of DC voltage and current.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB, LAN (10/100 Base-T), USB 2.0 (Host and Device), LXI Class C |
| Display | 4.3-inch color TFT-LCD, 480 × 272 resolution |
| Cooling System | Forced air cooling via internal fans (airflow from sides to rear) |
| Recommended Calibration Interval | 1 year |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 - 240 VAC (±10%), 50/60/400 Hz, 1440 VA max |
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 425.6 mm × 177.0 mm × 379.0 mm |
| Weight | 16 kg (empty mainframe) |
| Rack Mount Option Kit | N6705U-908 |
Mainframe System Capabilities
| Parameter | Value |
|---|---|
| Number of Slots | 4 |
| Maximum Total Output Power | 600 W |
| Compatible Module Series | Keysight N6700 Series |
| Basic Source Modules Compatibility | 50W, 100W, 300W; up to 100V, up to 20A |
| Precision Source Modules Compatibility | 50W, 100W; up to 50V, up to 3A |
Source / Output Performance (Module Dependent)
| Parameter | Value |
|---|---|
| Maximum Output Voltage | Up to 100 V (module dependent) |
| Maximum Output Current | Up to 50 A (module dependent) |
Measurement & Digitizer Specs
| Parameter | Value |
|---|---|
| Voltmeter Accuracy | Up to 0.016% + 1.5 mV (module dependent) |
| Voltmeter Resolution | Up to 18 bits |
| Ammeter Accuracy | Up to 0.03% + 15 µA (module dependent) |
| Ammeter Resolution | Up to 18 bits |
| Scope Digitizer Sampling Rate | 50 kHz |
| Scope Buffer Depth | 4096 points |
| Scope Digitizer Resolution | Up to 18 bits |
Arbitrary Waveform Generator (AWG) Capabilities
| Parameter | Value |
|---|---|
| AWG Bandwidth | Up to 4500 Hz |
| AWG Maximum Output Power | Up to 300 W |
Data Logging Functions
| Parameter | Value |
|---|---|
| Datalogger Measurement Interval | 1 ms to 60 s |
| Datalogger Maximum Capacity | 500 M readings per datalog |
| Non-Volatile Data Storage | 64 MB |
| Stored Parameters | Datalog, scope traces, instrument settings |
Triggering and Synchronization
| Parameter | Value |
|---|---|
| Digital I/O Pin Count | 8-pin programmable digital I/O port |
System Interfaces & Software Support
| Parameter | Value |
|---|---|
| GPIB Interface | Built-in (IEEE-488.2) |
| LAN Interface | 10/100 Base-T, LXI Class C compliant |
| USB Host Ports | USB 2.0 on front panel |
| USB Device Ports | USB 2.0 on rear panel |
| LXI Compliance Class | LXI Class C Compliant |
| Command Language | SCPI (Standard Commands for Programmable Instruments) |
User Interface
| Parameter | Value |
|---|---|
| Front Panel Physical Controls | Dedicated keys, rotary knobs, and color-coded connections |
Power and Mechanical Specs
| Parameter | Value |
|---|---|
| Form Factor (Rack Units) | 4U (four rack units) |
Environmental & Compliance
| Parameter | Value |
|---|---|
| Storage Temperature Range | -30°C to 70°C |
Power Requirements
| Parameter | Value |
|---|---|
| AC Input Voltage | 100 - 240 VAC |
| AC Input Frequency | 50 / 60 / 400 Hz |
| Maximum Input Power | 1440 VA |
| Power Factor | 0.99 (typical at nominal input and full load) |
Environmental
| Parameter | Value |
|---|---|
| Maximum Operating Altitude | 2000 m |
| Pollution Degree | 2 |
| Operating Humidity Range | Up to 95% RH (non-condensing) |
| Installation Category | Category II |
Interfaces & Connectivity
| Parameter | Value |
|---|---|
| LAN Connection Speed | 10/100 Base-T |
| Rear USB Interface Speed | USB 2.0 High Speed |
System Features
| Parameter | Value |
|---|---|
| Warm-up Time | 30 minutes |
Operating Limits
| Parameter | Value |
|---|---|
| Maximum Output Float Voltage | ±240 VDC (from any output terminal to chassis ground) |
Outputs
| Parameter | Value |
|---|---|
| Number of Channels Supported | Up to 4 |
Rear Panel Connections
| Parameter | Value |
|---|---|
| Digital I/O Connector Type | 8-pin |
| GPIB Connector Type | 24-pin ribbon, IEEE-488 compliant |
| LAN Connector Type | RJ-45 |
Compliance & Safety
| Parameter | Value |
|---|---|
| Safety Compliance | Complies with European Low Voltage Directive, EN 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1 |
| EMC Compliance | Complies with European EMC Directive, EN 61326-1, ICES-001, AS/NZS CISPR 11 |
Technology
DC Power Analysis
Applications