Keysight Technologies (Agilent HP) — Analyzers

68 models with full specifications in Analyzers.

This page summarizes how Keysight (formerly Agilent/HP) structures its analyzer offerings across spectrum/signal analyzers, vector network analyzers (VNAs), handheld FieldFox instruments, and purpose-built analyzers (impedance, semiconductor, EMC, communications). It is written for engineers and technical buyers who must pick an instrument by capability—frequency range, measurement set, portability, connector types, and dynamic-range or bandwidth needs—rather than brand positioning. Examples below illustrate where particular models sit in the range; the full model table (below) contains detailed specifications for each instrument.

Highest PNA VNA range (example)
E8361C: 10 MHz to 67 GHz
Handheld max frequency (FieldFox example)
N9952A: up to 50 GHz
Benchtop general‑purpose signal analyzer
N9000A: 9 kHz to 3.0 / 7.5 / 13.6 / 26.5 GHz (option dependent)
EMC analyzer coverage & detectors
E7405A: 9 kHz to 26.5 GHz; Peak, Quasi‑Peak, Average detectors

All models

ModelTypeDisplayInterfacesPower Supply
N9000A*misc8.4-inch color LCD (1024 × 768 resolution)USB 2.0 (Host & Device), 10/100/1000Base-T LAN, GPIB (IEEE-488), VGA output—
E8362C*misc26.4 cm (10.4 inch) TFT color LCD with touch screen——
N9918AMicrowave6.5-inch VGA (640 x 480) transflective color LED-backlit LCD2x USB 2.0 (Type A), 1x USB 2.0 (mini-B), LAN (100Base-T, RJ-45)15 to 19 VDC (4 A max), from included AC/DC adapter (100-240 VAC, 50-60 Hz)
N9914AMicrowave6.5-inch VGA (640 x 480) transflective color LCD with anti-glare and LED backlightLAN (RJ-45), 2x USB 2.0 Host (Type-A), 1x USB 2.0 Device (Mini-B)External DC input: 15 to 19 VDC (40 W max); AC/DC adapter: 100 to 240 VAC, 50 to 60 Hz
37718ACommunicationLarge color display——
N9917AMicrowave6.5-inch VGA (640 x 480) transflective color TFT LED—15 VDC via external AC/DC adapter; internal Lithium-ion battery
4294AImpedance8.4-inch color LCD (TFT)GPIB, LAN (10Base-T)90 to 132 V or 198 to 264 V AC, 47 to 63 Hz, 500 VA max
N9320B*misc6.5-inch TFT color LCDUSB Host, USB Device, LAN (10/100Base-T), GPIB (Option G01)100 to 240 VAC, 50/60 Hz, < 65 W
E7405A*misc—GPIB (IEEE-488), RS-232, Parallel (Centronics), VGA90 to 132 Vrms (47 to 440 Hz) / 195 to 250 Vrms (47 to 66 Hz); < 300 W max power consumption
N9952A*misc6.5-inch TFT color LCD, VGA (640 x 480) with LED backlight—15 to 19 VDC, 40 W maximum (charging)
U8903A*misc5.7-inch color TFT LCDUSB, LAN, GPIB100 to 240 VAC, 50/60 Hz
E4990AImpedance10.4-inch color TFT LCD touch screenUSB (Host/Device), LAN, GPIB, Handler90 to 264 VAC, 47 to 63 Hz
E8361C*misc——100 to 240 VAC, 50/60 Hz
N6705CPowerColor LCDLAN (LXI Core), USB 2.0 (Host and Device), GPIB100 to 240 VAC, 50 / 60 / 400 Hz, 1000 VA max
4194AImpedanceMonochrome CRT graphical displayGPIB (HP‑IB) remote control—
16803A*misc15-inch color LCD, 1024 × 768 pixels (XGA), optional touch screen——
16822A*misc15.0-inch color active matrix LCD with optional touch screen, 1024 x 768 (XGA) resolutionLAN (10/100/1000 Mb/s), 6 x USB 2.0 (2 front, 4 rear), 15-pin VGA output, External Trigger BNC input/output—
37717BCommunication———
4155ASemiconductor———
4291BImpedance———
N1996A*misc8.4-inch (213 mm) active matrix color TFT, VGA (640 x 480)LAN (10/100 Base-T), USB Host (Type-A), USB Device (Type-B), VGA out—
4155BSemiconductor8.4-inch active-matrix color LCD, 640 x 480 pixelsGPIB (IEEE-488), Parallel (Centronics), External Trigger, Keyboard (Mini-DIN)90 V to 264 V AC, 47 Hz to 63 Hz, 450 VA maximum
DSA91204A*misc———
83480ACommunication———
N6705BPower—GPIB, USB 2.0, LAN (10/100)100 - 240 VAC, 50/60/400 Hz, 1440 VA max
N9917B*misc——100 to 240 VAC, 50 to 60 Hz via external AC/DC adapter; 15 VDC, 4 A input
16823A*misc15-inch color TFT LCD, 1024 x 768 XGA resolution, optional touchscreenLAN (10/100/1000 Mb/s), 6 x USB 2.0 (2 front, 4 rear), VGA video out, External Trigger BNC, GPIB (optional)100 - 240 V AC (±10%), 50/60 Hz, 550 W maximum power consumption
4145BSemiconductor16 cm (6.25 in) diagonal CRT, electrostatic focus/deflection, post accelerated, aluminized P-31 phosphor, 2048 x 2048 resolutionGPIB (HP-IB)100/120/220 V AC +/-10%, 240 V AC -10% +5%, 48 to 66 Hz, 280 VA max
4156ASemiconductor9-inch color CRTGPIB (HP-IB), Parallel (Centronics), External I/O, Interlock, Analog Monitor Output90 V to 264 V AC, 47 Hz to 63 Hz, 450 VA maximum power consumption
4156CSemiconductor8.4-inch color active matrix LCD (640 × 480 VGA)GPIB, LAN (10Base-T), Parallel (Centronics)90 V to 264 V AC, 47 Hz to 63 Hz, 450 VA maximum
N6705APower4.3-inch color TFT-LCD, 480 × 272 resolutionGPIB, LAN (10/100 Base-T), USB 2.0 (Host and Device), LXI Class C100 - 240 VAC (±10%), 50/60/400 Hz, 1440 VA max
N9340A*misc7.2 in transflective TFT LCD, 640 x 480 pixelsUSB host (Type-A), USB device (Mini-B)100 to 240 V AC, 50 to 60 Hz (AC adapter input); 15 V DC, 4.0 A (AC adapter output)
16801A*misc15-inch color XGA LCD, 1024 x 768 resolution, optional touchscreenLAN (10/100/1000 Base-T), 6 x USB 2.0 (2 front, 4 rear), VGA, BNC Trigger In, BNC Trigger Out100 - 240 VAC ±10%, 47 - 63 Hz, 325 W max
16806A*misc15-inch color XGA TFT LCD, 1024 x 768 resolution (touchscreen optional)LAN (10/100/1000 Base-T), USB 2.0 (6 ports), VGA, DVI-I, Trigger In (BNC), Trigger Out (BNC)100 - 240 V AC ±10% @ 48 - 66 Hz / 400 Hz (100 - 120 V AC only), 325 W maximum
4192AImpedanceDual 4 1/2-digit 7-segment LED displays with parameter indicatorsHP-IB (GPIB)100 / 120 / 220 / 240 V ±10% (switchable), 48 to 66 Hz, ≤150 VA
86108AWaveformNone (utilizes host mainframe display)Mainframe backplane (host mainframe provides GPIB, LAN, and USB)Powered directly by the host mainframe slot
8702DCommunication9-inch color CRTGPIB (IEEE-488), Parallel (Centronics), External VGA Video Output90 to 132 Vac (47 to 66 Hz) or 198 to 264 Vac (47 to 66 Hz), 280 VA maximum
8991APowerMonochrome CRTGPIB (IEEE-488.2)115 Vac (90 to 127 Vac) / 230 Vac (195 to 253 Vac), 48 - 66 Hz (or 360 - 440 Hz at 115 Vac), 250 VA max
N9320A*misc6.4-inch TFT color display, 640 x 480 resolutionUSB Host (front and rear), USB Device (rear), LAN (RJ-45), GPIB (optional, Option G01)100 to 240 VAC, 50 to 60 Hz; power consumption < 100 W
N9915AMicrowave6.5-inch transflective color LCD, 640 x 480 resolutionLAN, USB 2.0 host (2 ports), USB 2.0 device (1 port), micro-SD slot, external reference, GPS antenna, audio jack100 to 240 VAC, 50 to 60 Hz (AC/DC adapter); 15 to 19 VDC input; 14 W typical power consumption
11853AComponent———
1662C*misc9-inch color CRT, 640 x 480 resolutionHP-IB (GPIB), RS-232C, Centronics Parallel Printer Port, PS/2-style keyboard/mouse115/230 V AC auto-ranging, 48-66 Hz, 200 VA maximum
16821A*misc15-inch color active matrix LCD, 1024 x 768 (XGA) resolution, optional touch screenLAN (10/100/1000 Base-T), 6 x USB 2.0, VGA, Trigger In/Out100 - 240 V AC (±10%), 47 - 63 Hz, 615 W max
37717CCommunication9.5-inch active matrix color TFT LCDGPIB (IEEE-488), RS-232, Parallel (Centronics), LAN (10Base-T Ethernet) via module options100 to 240 V AC (±10%), 47 to 63 Hz, 350 VA max power consumption
4155CSemiconductor8.4-inch color active matrix LCD, 640×480 VGA resolutionGPIB (IEEE-488), LAN (10BASE-T/100BASE-TX), Parallel (Centronics)90 V to 264 V AC, 47 Hz to 63 Hz, 450 VA maximum power consumption
4156B*misc8.4-inch TFT color LCDGPIB (HP-IB), Parallel (Centronics), External I/O90 V to 264 V AC, 47 Hz to 63 Hz, 450 VA maximum
4191AImpedanceDual 4.5-digit digital displaysHP-IB (IEEE-488)100, 120, 220 V ±10%, 240 V +5%/-10%, 48 to 66 Hz, ≤150 VA
4291AImpedance7.5-inch Color CRT, 512 x 400 resolution, 2 channelsHP-IB (IEEE-488) supporting SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP0, DC1, DT1, C1, C2, C3, C4, C11, E290 V to 132 V / 198 V to 264 V, 47 Hz to 66 Hz, 500 VA max

Looking for Keysight Technologies (Agilent HP) — Analyzers?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us

How the range is organized

Keysight groups analyzers by the measurement domain and intended use. Broad categories visible in this lineup are:

  • Benchtop spectrum and signal analyzers for lab and service work. Examples include the N9000A CXA class (configurable to different top-end frequencies) and production/service analyzers like the N9320B/N9340A family for 3 GHz-class needs.
  • High-performance VNAs in the Microwave PNA series for demanding S‑parameter work (E8362C, E8361C). These instruments list sweep point counts, connector types, and dynamic range figures appropriate for component and network verification.
  • Rugged handheld FieldFox instruments (N9914A, N9915A, N9917A/B, N9918A, N9952A) that combine CAT, VNA and SA functions for field installation, antenna and cable test, and on-site VNA measurements.
  • Specialized analyzers for impedance/materials, semiconductor parameter characterization, EMC and communications test (E4990A/E4294A, 4156C/4155B/4155A, E7405A, 37718A).

What distinguishes each family

Focus and notable specification examples:

  • PNA VNAs (E8362C, E8361C): built for accuracy and dynamic range. The E8362C specifies up to 123 dB dynamic range and a multi‑channel/high‑point sweep capability; the E8361C extends frequency coverage to 67 GHz and uses 1.85 mm test ports.

  • Benchtop spectrum/signal analyzers (N9000A, N9320B): offered with different maximum frequencies and RBW/VBW choices. The N9000A is positioned as an economical, general‑purpose CXA analyzer with RBW down to 1 Hz and analysis bandwidth options.

  • FieldFox handhelds (N9914A, N9915A, N9917A/B, N9918A, N9952A): combine multiple measurement modes (CAT, VNA, SA) with rugged enclosures and varied frequency coverage — from single‑digit GHz up to 50 GHz on configured units. Connector types and ECal support differ (for example, N9917B uses Type‑N ports; N9952A uses 2.4 mm ports where fitted).

  • Specialized instruments: impedance analyzers such as the E4990A and 4294A provide dedicated frequency ranges and DC bias capability; semiconductor analyzers (4156C/4155B) provide multiple SMU channels and sub‑microamp to femtoamp resolution for device characterization; EMC analyzers like the E7405A supply CISPR bandwidths and quasi‑peak detectors.

Practical selection guidance

Match the measurement task to these concrete criteria:

  • Frequency coverage: pick an instrument whose stated frequency range covers the DUT and measurement bandwidth (examples: use an E8361C when S‑parameter test must extend to 67 GHz; consider N9952A FieldFox when handheld testing requires up to 50 GHz).

  • Measurement set and instrumentation density: if you need only spectrum and basic signal analysis at up to 3 GHz, compact benchtop models such as the N9320B or handheld N9340A/N9340 family are relevant. If you need VNA capability plus cable/antenna analysis in the field, a FieldFox (N9915A–N9918A series) combines both.

  • Accuracy, dynamic range and ports: for component characterization and high dynamic range S‑parameter measurement, PNA series units (E8362C, E8361C) specify high dynamic range and precise connectors (3.5 mm or 1.85 mm) and large sweep point capability.

  • Portability and environment: handheld FieldFox models list operating-temperature and IP/shock compliance details; choose them when bench space or transportability is a requirement.

  • Specialized needs: pick an impedance analyzer (E4990A, 4294A) for materials and component impedance over dedicated frequency bands, or a semiconductor parameter analyzer (4156C, 4155B) when SMU count, voltage/current ranges and resolution matter.

Connector, interfaces and expandability to check

Before committing, verify the specific model option and connector set you need:

  • Test ports and calibration: PNA VNAs specify connector types (E8362C: 3.5 mm male; E8361C: 1.85 mm male). Field units list port type (N9917B: Type‑N female; N9952A: 2.4 mm male on test ports).

  • Bandwidth and real‑time capability: some handhelds and field analyzers list options for real‑time bandwidth (N9952A: Maximum Real‑Time Bandwidth 10 MHz with Option 350).

  • Digital and remote control: mainstream Keysight analyzers include USB, LAN, GPIB or SCPI command support; confirm the interfaces required for automated test or data logging.

Popular models

Frequently asked questions

When should I choose a FieldFox handheld vs a benchtop spectrum analyzer?
Choose a FieldFox when you need multifunction field measurements (CAT, VNA, SA) and ruggedness. FieldFox models span options such as 30 kHz to 9 GHz (N9915A), 30 kHz to 18 GHz (N9917A), up to 26.5 GHz (N9918A) and up to 50 GHz (N9952A). Choose a benchtop analyzer like the N9000A or N9320B when lab accuracy, larger displays, and bench‑oriented interfaces are more important.
Which Keysight VNA should I consider for millimeter‑wave component work?
For the widest stated frequency coverage in this list, the E8361C Microwave PNA is specified from 10 MHz to 67 GHz and uses 1.85 mm test ports. The E8362C is a PNA variant offering a high dynamic range (123 dB) for demanding network measurements.
Which model is intended for EMI precompliance and what to check?
The E7405A is presented as a portable EMC analyzer covering 9 kHz to 26.5 GHz and lists EMI detectors (Peak, Quasi‑Peak, Average) plus CISPR RBW settings. Confirm the detector modes and CISPR bandwidths needed for your tests against the model's listed capabilities.