The Keysight (formerly Agilent) N6730 Series are 50 W basic DC power modules designed for use in the N6700 low-profile modular power system mainframes and the N6705 DC Power Analyzer. The series includes the N6731B through N6736B modules, providing programmable voltage and current, as well as essential measurement and protection features. These single-slot modules offer an economical solution for ATE systems and general-purpose device testing where basic performance is required.
Specifications
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 55 |
| Weight | 1.23 kg |
Output Ratings
| Parameter | Value |
|---|---|
| Maximum Output Power | 50 W (nominal class rating) |
| Number of Outputs per Module | 1 |
| Maximum Output Voltage | 100 V (model N6736B) |
| Maximum Output Current | 10 A (model N6731B) |
| Output Voltage (N6731B) | 0 to 5 V |
| Output Current (N6731B) | 0 to 10 A |
| Output Voltage (N6732B) | 0 to 8 V |
| Output Current (N6732B) | 0 to 6.25 A |
| Output Voltage (N6733B) | 0 to 20 V |
| Output Current (N6733B) | 0 to 2.5 A |
| Output Voltage (N6734B) | 0 to 35 V |
| Output Current (N6734B) | 0 to 1.5 A |
| Output Voltage (N6735B) | 0 to 60 V |
| Output Current (N6735B) | 0 to 0.8 A |
| Output Voltage (N6736B) | 0 to 100 V |
| Output Current (N6736B) | 0 to 0.5 A |
Output Protection
| Parameter | Value |
|---|---|
| Overvoltage Protection (OVP) | Yes (Programmable) |
| Overcurrent Protection (OCP) | Yes (Programmable) |
General Characteristics
| Parameter | Value |
|---|---|
| Remote Sense Maximum Voltage Drop | Up to 1 V per load lead |
Physical and Mechanical
| Parameter | Value |
|---|---|
| Mainframe Slot Requirement | 1 slot per module |
| Compatible Mainframes | Keysight N6700, N6701, N6702, N6710, N6711, N6712, and N6705 Series |
| Cooling Method | Provided by mainframe fan |
Accuracy
| Parameter | Value |
|---|---|
| Voltage Programming Accuracy | 0.1% + 19 mV to 100 mV (model dependent) |
| Current Programming Accuracy | 0.15% + 5 mA to 10 mA (model dependent) |
| Voltage Readback Accuracy | 0.1% + 19 mV to 100 mV (model dependent) |
| Current Readback Accuracy | 0.15% + 5 mA to 10 mA (model dependent) |
Performance
| Parameter | Value |
|---|---|
| CV Ripple & Noise (Peak-to-Peak) | 12 mV to 30 mV (model dependent, 20 Hz to 20 MHz) |
| CV Ripple & Noise (RMS) | 2 mV to 18 mV (model dependent, 20 Hz to 20 MHz) |
| Load Regulation (Current) | 2 mA |
| Line Regulation (Current) | 1 mA |
| Ripple & Noise Bandwidth | 20 Hz to 20 MHz |
General
| Parameter | Value |
|---|---|
| Output Isolation | ±240 Vdc (from ground) |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -40 °C to 85 °C |
Control & Software
| Parameter | Value |
|---|---|
| Output Turn-On/Turn-Off Delay | 0 to 3600 seconds (programmable) |
Options
| Parameter | Value |
|---|---|
| Output Relays (Option 761) | Output disconnect and polarity reversal relays |
| High-Speed Test Extension (Option 054) | Adds high-speed digitizing and advanced sequencing |
Technology
Modular DC Power Supply
Applications
Automated Test Equipment (ATE), Device Powering, Fixture Control