- Home
- Categories
- Test equipment
- Power Supplies
- Agilent HP
- N6740 Series - 100W Modules
The Keysight (formerly Agilent) N6740 Series consists of basic DC power modules providing 100 W of programmable voltage and current for the N6700 Low-Profile Modular Power System and N6705 DC Power Analyzer mainframes. Designed for economy and flexibility, the series includes the N6741B, N6742B, N6743B, N6744B, N6745B, and N6746B modules, covering voltage ranges up to 100 V and currents up to 20 A. These 1-slot modules are ideal for providing power to devices under test (DUT) or automating ATE system resources.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | Provided by mainframe (USB, LAN/LXI, GPIB) |
| Display | Provided by mainframe |
| Module Classification | Basic DC Power Module |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 55 |
| Weight | 1.23 kg |
DC Output Ratings
| Parameter | Value |
|---|---|
| Output Power | 100 W nominal (96 W to 100 W depending on model) |
| Output Voltage Range | 0 to 5 V (N6741B), 0 to 8 V (N6742B), 0 to 20 V (N6743B), 0 to 35 V (N6744B), 0 to 60 V (N6745B), 0 to 100 V (N6746B) |
| Output Current Range | 0 to 20 A (N6741B), 0 to 12.5 A (N6742B), 0 to 5 A (N6743B), 0 to 2.8 A (N6744B), 0 to 1.6 A (N6745B), 0 to 1 A (N6746B) |
Output Ripple and Noise
| Parameter | Value |
|---|---|
| Constant Voltage (CV) Peak-to-Peak (20 Hz - 20 MHz) | 20 mV (N6741B/42B/43B), 22 mV (N6744B), 25 mV (N6745B), 30 mV (N6746B) |
| Constant Voltage (CV) RMS (20 Hz - 20 MHz) | 2 mV (N6741B/42B), 3 mV (N6743B), 5 mV (N6744B), 9 mV (N6745B), 18 mV (N6746B) |
Programming Accuracy
| Parameter | Value |
|---|---|
| Voltage Programming Accuracy | ±(0.1% + 19 mV) for N6741B/42B; ±(0.1% + 20 mV) for N6743B; ±(0.1% + 35 mV) for N6744B; ±(0.1% + 60 mV) for N6745B; ±(0.1% + 100 mV) for N6746B |
| Current Programming Accuracy | ±(0.15% + 20 mA) for N6741B; ±(0.15% + 12.5 mA) for N6742B; ±(0.15% + 5 mA) for N6743B; ±(0.15% + 2.8 mA) for N6744B; ±(0.15% + 1.6 mA) for N6745B; ±(0.15% + 1 mA) for N6746B |
Measurement (Readback) Accuracy
| Parameter | Value |
|---|---|
| Voltage Readback Accuracy | ±(0.1% + 19 mV) for N6741B/42B; ±(0.1% + 20 mV) for N6743B; ±(0.1% + 35 mV) for N6744B; ±(0.1% + 60 mV) for N6745B; ±(0.1% + 100 mV) for N6746B |
| Current Readback Accuracy | ±(0.15% + 20 mA) for N6741B; ±(0.15% + 12.5 mA) for N6742B; ±(0.15% + 5 mA) for N6743B; ±(0.15% + 2.8 mA) for N6744B; ±(0.15% + 1.6 mA) for N6745B; ±(0.15% + 1 mA) for N6746B |
Protection Functions
| Parameter | Value |
|---|---|
| Over-Temperature Protection (OTP) | Standard / Included |
Physical Specifications
| Parameter | Value |
|---|---|
| Module Width (Slots) | 1 slot |
| System Compatibility | Keysight N6700, N6701, N6702 Low-Profile Mainframes and N6705 DC Power Analyzer |
Outputs
| Parameter | Value |
|---|---|
| Remote Sense Drop (Max) | 1 V per load lead |
| Output Isolation | ±240 VDC from chassis ground |
Performance
| Parameter | Value |
|---|---|
| Command Processing Time | ≤ 1 ms |
Protection
| Parameter | Value |
|---|---|
| Over-Voltage Protection (OVP) | Standard |
| Over-Current Protection (OCP) | Standard |
Options
| Parameter | Value |
|---|---|
| Disconnect & Polarity Reversal Relays | Available via Option 761 |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -30 °C to 70 °C |
| Operating Altitude | Up to 2000 m |
| Pollution Degree | 2 |
Features
| Parameter | Value |
|---|---|
| Parallel Operation | Supported (up to 4 identical modules) |
Technology
Programmable Modular DC Power Supply
Applications
Automated Test Equipment (ATE), DUT powering, fixture control, general-purpose DC power