- Home
- Categories
- Test equipment
- Power Supplies
- Agilent HP
- N6750 Series - 50W, 100W, 300W Modules
The Keysight N6750 Series (part of the N6700 Series mainframe system) comprises high-performance, autoranging DC power modules. These modules offer low noise, high accuracy, and fast programming speeds, designed to simplify system configuration and enhance measurement accuracy, particularly for high-speed transient or pulse events. The autoranging capability allows a single module to cover a wider range of voltage and current outputs.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | Via N6700 series mainframe: LAN (LXI C), USB 2.0, GPIB |
| Display | None (controlled via N6700 mainframe display or remote interface) |
| Warm-up Time | 30 min (to rated specifications) |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 34 mm (W) x 84 mm (H) x 457 mm (D) |
| Weight | 1.0 to 1.3 kg (module dependent) |
| Output Terminals | Front panel binding posts (accepts banana plugs, spade lugs) |
Overview & Key Specifications
| Parameter | Value |
|---|---|
| Product Series Compatibility | Keysight N6700 Series Mainframes (N6700B, N6701C, N6702C, N6705C) |
| Module Type | High-Performance Autoranging DC Power Module |
| Output Channels | 1 per module |
| Maximum Output Voltage | Up to 100 V (model dependent) |
| Maximum Output Current | Up to 15 A (model dependent) |
| Maximum Output Power | 50 W, 100 W, or 300 W (model dependent) |
Output Performance Specifications
| Parameter | Value |
|---|---|
| Voltage Programming Range | 0 to 20 V, 0 to 50 V, 0 to 60 V, or 0 to 100 V (model dependent) |
| Current Programming Range | 0 to 1 A, 0 to 2.5 A, 0 to 3 A, 0 to 5 A, 0 to 6 A, or 0 to 15 A (model dependent) |
| Voltage Programming Accuracy | 0.025% of output + 5 mV (up to 50V outputs); 0.025% of output + 10 mV (60V/100V outputs) |
| Current Programming Accuracy | 0.04% of output + 2.5 mA (for 1A to 6A outputs); 0.04% of output + 5 mA (for 3A outputs); 0.04% of output + 15 mA (for 15A output) |
| Load Regulation (Voltage) | 0.01% of output + 2 mV |
| Load Regulation (Current) | 0.02% of output + 2 mA |
| Line Regulation (Voltage) | 0.01% of output + 2 mV |
| Line Regulation (Current) | 0.02% of output + 2 mA |
| Ripple and Noise (Voltage Peak-to-Peak) | <10 mV (20Hz-20MHz), typical for 50V/100V outputs |
| Ripple and Noise (Voltage RMS) | <1 mV (20Hz-20MHz), typical for 50V/100V outputs |
| Ripple and Noise (Current RMS) | <2 mA (20Hz-20MHz), typical |
| Transient Response Time | <1 ms (to recover to within 0.1% of programmed voltage for a 50% load change) |
| Output Rise Time (typical) | <2 ms (full load) |
| Output Fall Time (typical) | <2 ms (full load) |
| Over Voltage Protection (OVP) Threshold | Programmable, 110% to 120% of maximum rated voltage |
| Over Current Protection (OCP) Threshold | Programmable, 105% to 110% of maximum rated current |
| Remote Sensing Capability | Yes |
Measurement Performance Specifications
| Parameter | Value |
|---|---|
| Voltage Measurement Range | Full output range |
| Current Measurement Range | Full output range |
| Voltage Measurement Accuracy | 0.025% of reading + 5 mV (up to 50V outputs); 0.025% of reading + 10 mV (60V/100V outputs) |
| Current Measurement Accuracy | 0.04% of reading + 2.5 mA (for 1A to 6A outputs); 0.04% of reading + 5 mA (for 3A outputs); 0.04% of reading + 15 mA (for 15A output) |
| Voltage Measurement Resolution | 1 mV |
| Current Measurement Resolution | 0.1 mA (for lower currents), 1 mA (for higher currents) |
Advanced Features & Capabilities
| Parameter | Value |
|---|---|
| High-Speed Digitizer | Up to 50 kHz sampling rate, 128 kpts memory |
| Output Sequencer | Yes, via N6700 mainframe |
| Data Logger | Yes, via N6700 mainframe |
| Arbitrary Waveform Generation | Yes, with high-speed digitizer |
Programming & Interfaces
| Parameter | Value |
|---|---|
| Programming Language | SCPI (Standard Commands for Programmable Instruments) |
| Driver Support | IVI-COM, IVI-C, LabVIEW |
| Remote Control Software Compatibility | custom applications |
Environmental Characteristics
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to 70 °C |
| Operating Humidity Range | 15% to 85% RH, non-condensing |
| Storage Humidity Range | Up to 90% RH, non-condensing |
| Operating Altitude | Up to 2000 m (6561 ft) |
| Non-operating Altitude | Up to 4600 m (15091 ft) |
| Pollution Degree | 2 |
Physical Characteristics
| Parameter | Value |
|---|---|
| Module Slot Count | 1 |
| Cooling Method | Fan-cooled (via mainframe) |
Compliance & Certifications
| Parameter | Value |
|---|---|
| Safety Standards | IEC/EN 61010-1, CSA C22.2 No. 61010-1 |
| Electromagnetic Compatibility (EMC) | IEC/EN 61326-1, CISPR 11 |
| CE Mark | Yes |
| CSA/UL Listing | Yes |
| RoHS Compliance | Yes |
Ordering Information
| Parameter | Value |
|---|---|
| Available Models | N6751A (50W), N6752A (100W), N6753A (300W), N6754A (300W), N6755A (300W), N6756A (300W), N6757A (300W), N6758A (300W) |
| Included Accessories | Connector block, Installation guide |
| Warranty Period | 3 years |
| Recommended Calibration Interval | 1 year |
Output Characteristics
| Parameter | Value |
|---|---|
| Output Isolation (Output to Chassis) | >10 GΩ in parallel with <1000 pF (typical) |
| Max Output Float Voltage (to chassis) | 60 VDC |
Protection
| Parameter | Value |
|---|---|
| Over Temperature Protection (OTP) | Yes, automatic shutdown |
| Reverse Voltage Protection | Yes, protects up to rated output voltage |
Performance
| Parameter | Value |
|---|---|
| Remote Sense Lead Compensation | Up to 0.5 Ω per lead (1 Ω total) |
| Voltage Program Speed (Up) | < 1 ms (typical) |
| Voltage Program Speed (Down) | < 1 ms (typical) |
| Current Program Speed (Up) | < 1 ms (typical) |
| Current Program Speed (Down) | < 1 ms (typical) |
| Max Remote Sense Lead Compensation | 1 V per lead |
| AWG Sample Rate | Up to 50 kHz |
| AWG Buffer Size | 65535 points |
| Trigger Latency | < 100 µs (typical) |
Measurement
| Parameter | Value |
|---|---|
| Digitizer Sample Rate | Up to 50 kHz |
| Digitizer Resolution | 16-bit |
Interfaces
| Parameter | Value |
|---|---|
| Hardware Trigger | Trigger In/Out |
Technology
Programmable DC Power Supply, Autoranging, High-Speed Digitizer
Applications
Automated Test Equipment (ATE), Device Under Test (DUT) characterization, General purpose benchtop and system test, Component testing, System power validation