- Home
- Categories
- Test equipment
- Power Supplies
- Agilent HP
- N6750 Series - 50W, 100W, 300W Modules
The Keysight N6750 Series (part of the N6700 Series mainframe system) comprises high-performance, autoranging DC power modules. These modules offer low noise, high accuracy, and fast programming speeds, designed to simplify system configuration and enhance measurement accuracy, particularly for high-speed transient or pulse events. The autoranging capability allows a single module to cover a wider range of voltage and current outputs.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | Via N6700 series mainframe: LAN (LXI C), USB 2.0, GPIB |
| Display | None (controlled via N6700 mainframe display or remote interface) |
| Warm-up Time | 30 min (to rated specifications) |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 34 mm (W) x 84 mm (H) x 457 mm (D) |
| Weight | 1.0 to 1.3 kg (module dependent) |
| Output Terminals | Front panel binding posts (accepts banana plugs, spade lugs) |
Overview & Key Specifications
| Parameter | Value |
|---|---|
| Product Series Compatibility | Keysight N6700 Series Mainframes (N6700B, N6701C, N6702C, N6705C) |
| Module Type | High-Performance Autoranging DC Power Module |
| Output Channels | 1 per module |
| Maximum Output Voltage | Up to 100 V (model dependent) |
| Maximum Output Current | Up to 15 A (model dependent) |
| Maximum Output Power | 50 W, 100 W, or 300 W (model dependent) |
Output Performance Specifications
| Parameter | Value |
|---|---|
| Voltage Programming Range | 0 to 20 V, 0 to 50 V, 0 to 60 V, or 0 to 100 V (model dependent) |
| Current Programming Range | 0 to 1 A, 0 to 2.5 A, 0 to 3 A, 0 to 5 A, 0 to 6 A, or 0 to 15 A (model dependent) |
| Voltage Programming Accuracy | 0.025% of output + 5 mV (up to 50V outputs); 0.025% of output + 10 mV (60V/100V outputs) |
| Current Programming Accuracy | 0.04% of output + 2.5 mA (for 1A to 6A outputs); 0.04% of output + 5 mA (for 3A outputs); 0.04% of output + 15 mA (for 15A output) |
| Load Regulation (Voltage) | 0.01% of output + 2 mV |
| Load Regulation (Current) | 0.02% of output + 2 mA |
| Line Regulation (Voltage) | 0.01% of output + 2 mV |
| Line Regulation (Current) | 0.02% of output + 2 mA |
| Ripple and Noise (Voltage Peak-to-Peak) | <10 mV (20Hz-20MHz), typical for 50V/100V outputs |
| Ripple and Noise (Voltage RMS) | <1 mV (20Hz-20MHz), typical for 50V/100V outputs |
| Ripple and Noise (Current RMS) | <2 mA (20Hz-20MHz), typical |
| Transient Response Time | <1 ms (to recover to within 0.1% of programmed voltage for a 50% load change) |
| Output Rise Time (typical) | <2 ms (full load) |
| Output Fall Time (typical) | <2 ms (full load) |
| Over Voltage Protection (OVP) Threshold | Programmable, 110% to 120% of maximum rated voltage |
| Over Current Protection (OCP) Threshold | Programmable, 105% to 110% of maximum rated current |
| Remote Sensing Capability | Yes |
Measurement Performance Specifications
| Parameter | Value |
|---|---|
| Voltage Measurement Range | Full output range |
| Current Measurement Range | Full output range |
| Voltage Measurement Accuracy | 0.025% of reading + 5 mV (up to 50V outputs); 0.025% of reading + 10 mV (60V/100V outputs) |
| Current Measurement Accuracy | 0.04% of reading + 2.5 mA (for 1A to 6A outputs); 0.04% of reading + 5 mA (for 3A outputs); 0.04% of reading + 15 mA (for 15A output) |
| Voltage Measurement Resolution | 1 mV |
| Current Measurement Resolution | 0.1 mA (for lower currents), 1 mA (for higher currents) |
Advanced Features & Capabilities
| Parameter | Value |
|---|---|
| High-Speed Digitizer | Up to 50 kHz sampling rate, 128 kpts memory |
| Output Sequencer | Yes, via N6700 mainframe |
| Data Logger | Yes, via N6700 mainframe |
| Arbitrary Waveform Generation | Yes, with high-speed digitizer |
Programming & Interfaces
| Parameter | Value |
|---|---|
| Programming Language | SCPI (Standard Commands for Programmable Instruments) |
| Driver Support | IVI-COM, IVI-C, LabVIEW |
| Remote Control Software Compatibility | custom applications |
Environmental Characteristics
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to 70 °C |
| Operating Humidity Range | 15% to 85% RH, non-condensing |
| Storage Humidity Range | Up to 90% RH, non-condensing |
| Operating Altitude | Up to 2000 m (6561 ft) |
| Non-operating Altitude | Up to 4600 m (15091 ft) |
| Pollution Degree | 2 |
Physical Characteristics
| Parameter | Value |
|---|---|
| Module Slot Count | 1 |
| Cooling Method | Fan-cooled (via mainframe) |
Compliance & Certifications
| Parameter | Value |
|---|---|
| Safety Standards | IEC/EN 61010-1, CSA C22.2 No. 61010-1 |
| Electromagnetic Compatibility (EMC) | IEC/EN 61326-1, CISPR 11 |
| CE Mark | Yes |
| CSA/UL Listing | Yes |
| RoHS Compliance | Yes |
Ordering Information
| Parameter | Value |
|---|---|
| Available Models | N6751A (50W), N6752A (100W), N6753A (300W), N6754A (300W), N6755A (300W), N6756A (300W), N6757A (300W), N6758A (300W) |
| Included Accessories | Connector block, Installation guide |
| Warranty Period | 3 years |
| Recommended Calibration Interval | 1 year |
Output Characteristics
| Parameter | Value |
|---|---|
| Output Isolation (Output to Chassis) | >10 GΩ in parallel with <1000 pF (typical) |
| Max Output Float Voltage (to chassis) | 60 VDC |
Protection
| Parameter | Value |
|---|---|
| Over Temperature Protection (OTP) | Yes, automatic shutdown |
| Reverse Voltage Protection | Yes, protects up to rated output voltage |
Performance
| Parameter | Value |
|---|---|
| Remote Sense Lead Compensation | Up to 0.5 Ω per lead (1 Ω total) |
| Voltage Program Speed (Up) | < 1 ms (typical) |
| Voltage Program Speed (Down) | < 1 ms (typical) |
| Current Program Speed (Up) | < 1 ms (typical) |
| Current Program Speed (Down) | < 1 ms (typical) |
| Max Remote Sense Lead Compensation | 1 V per lead |
| AWG Sample Rate | Up to 50 kHz |
| AWG Buffer Size | 65535 points |
| Trigger Latency | < 100 µs (typical) |
Measurement
| Parameter | Value |
|---|---|
| Digitizer Sample Rate | Up to 50 kHz |
| Digitizer Resolution | 16-bit |
Interfaces
| Parameter | Value |
|---|---|
| Hardware Trigger | Trigger In/Out |
Technology
Programmable DC Power Supply, Autoranging, High-Speed Digitizer
Applications
Automated Test Equipment (ATE), Device Under Test (DUT) characterization, General purpose benchtop and system test, Component testing, System power validation
Looking for the Keysight Technologies (Agilent HP) N6750 Series - 50W, 100W, 300W Modules?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us