The Keysight N6755A (formerly Agilent) is a 500 W high-performance, autoranging DC power module designed for use with the N6700 Low-Profile Modular Power System and the N6705 DC Power Analyzer. It features low noise, high-speed programming up to 10 to 50 times faster than other programmable power supplies, and optional high-speed test extensions including a digitizer and arbitrary waveform generator.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB, LAN, USB (via mainframe) |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 °C to 55 °C |
| Dimensions (W×H×D) | 68.2 mm × 128.4 mm × 211.6 mm |
| Weight | 1.63 kg |
Output Ratings
| Parameter | Value |
|---|---|
| DC Output Voltage | 0 to 20 V |
| DC Output Current | 0 to 50 A |
| Maximum Output Power | 500 W |
| Output Type | Autoranging |
| Voltage Programming Range | 10 mV - 20.4 V |
| Current Programming Range | 50 mA - 51 A |
Programming Accuracy
| Parameter | Value |
|---|---|
| Voltage Programming Accuracy | 0.06% + 10 mV (at 23°C ±5°C) |
| Current Programming Accuracy | 0.1% + 30 mA (at 23°C ±5°C) |
Ripple and Noise
| Parameter | Value |
|---|---|
| Constant Voltage Ripple (RMS) | 1 mV (20 Hz to 20 MHz) |
| Constant Voltage Ripple (Peak-to-Peak) | 5 mV (20 Hz to 20 MHz) |
| Constant Current Ripple (RMS) | 12 mA (20 Hz to 20 MHz) |
| Common Mode Noise Current (Peak-to-Peak) | <2 mA |
Load and Line Regulation
| Parameter | Value |
|---|---|
| Constant Voltage Load Regulation | 2 mV (Load Effect) |
| Constant Current Load Regulation | 12 mA (Load Effect) |
| Constant Voltage Line Regulation | 0.5 mV (Source Effect) |
| Constant Current Line Regulation | 2 mA (Source Effect) |
| Remote Sensing Voltage Drop Allowance | Up to 1 V drop per load lead (reduces max voltage at load) |
Programming and Measurement Resolution
| Parameter | Value |
|---|---|
| Voltage Programming Resolution | 1.5 mV |
| Current Programming Resolution | 16.3 mA |
| Voltage Measurement Resolution | 0.8 mV |
| Current Measurement Resolution | 4.1 mA |
Protection and Diagnostics
| Parameter | Value |
|---|---|
| Over-Voltage Protection (OVP) Maximum Setting | 22 V |
Interface and Control Features
| Parameter | Value |
|---|---|
| Minimum Output Turn-On Delay (Without Relay Option) | 18 ms |
| Minimum Output Turn-On Delay (With Relay Option) | 44 ms |
| Mainframe Slot Width | 2 slots (double-wide) |
| Series Operation | Identically rated outputs can be operated in straight series (auto-series not supported) |
| Parallel Operation | Identically rated outputs can be operated in parallel (auto-parallel is supported) |
| Mainframe Compatibility | N6700 Low-Profile Modular Power System, N6705 DC Power Analyzer |
| High-Speed Test Extensions | Supported (optional digitizer and arbitrary waveform generator capabilities) |
Measurement Accuracy
| Parameter | Value |
|---|---|
| Voltage Measurement Accuracy | 0.05% + 10 mV |
| Current Measurement Accuracy (High Range) | 0.1% + 30 mA |
| Current Measurement Accuracy (Low Range) | 0.1% + 100 µA (on 100 mA range) |
Measurement
| Parameter | Value |
|---|---|
| Current Measurement Ranges | 100 mA, 50 A |
| Current Measurement Low Range | 100 mA |
Programming Speed
| Parameter | Value |
|---|---|
| Voltage Upward Settling Time | 1.5 ms (with full resistive load) |
| Voltage Downward Settling Time | 20 ms (with no load) |
Performance
| Parameter | Value |
|---|---|
| Transient Response Recovery Time | < 100 µs (to within 75 mV of nominal output after a 50% to 100% load change) |
| Command Processing Time | < 1 ms |
Protection
| Parameter | Value |
|---|---|
| OVP Accuracy | 0.25% + 250 mV |
| OVP Response Time | 50 µs |
Isolation
| Parameter | Value |
|---|---|
| Maximum Float Voltage | 240 VDC (from chassis ground) |
Temperature Coefficients
| Parameter | Value |
|---|---|
| Voltage Programming Temperature Coefficient | 0.01% + 1 mV per °C |
| Current Programming Temperature Coefficient | 0.01% + 2 mA per °C |
| Voltage Measurement Temperature Coefficient | 0.01% + 1 mV per °C |
| Current Measurement Temperature Coefficient | 0.01% + 2 mA per °C |
Output
| Parameter | Value |
|---|---|
| Output Autoranging | Yes (up to 20 V / 50 A, 500 W max) |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to 70 °C |
| Operating Humidity | Up to 95% RH (non-condensing) |
Maintenance
| Parameter | Value |
|---|---|
| Recommended Calibration Interval | 1 year |
Applications