The Keysight (Agilent) N6764A is a 300W precision DC power module designed for use with the N6700 Low-Profile Modular Power System and N6705 DC Power Analyzer mainframes. It features high precision, low noise, and dual-digitizers for simultaneous voltage and current measurements down to the microampere region.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB, LAN, USB, and LXI Class C (via host mainframe) |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 - 55 |
| Dimensions (W×H×D) | 70.4 × 47 × 341 |
| Weight | 1.4 |
| Module Slot Width | 2 slots (double-wide) |
Output Ratings and Capabilities
| Parameter | Value |
|---|---|
| Number of Channels | 1 |
| Rated Output Power | 300 W |
| Rated Output Voltage | 60 V |
| Rated Output Current | 20 A |
| Series and Parallel Connection | Identically rated outputs can be operated directly in series or parallel; auto-series and auto-parallel not supported |
Load and Line Regulation
| Parameter | Value |
|---|---|
| Voltage Load Regulation | 2 mV |
| Current Load Regulation | 12 mA |
| Voltage Line Regulation | 1.2 mV |
| Current Line Regulation | 2 mA |
Ripple and Noise
| Parameter | Value |
|---|---|
| Constant Voltage Ripple and Noise (Vp-p, 20 Hz to 20 MHz) | 6 mV |
| Constant Voltage Ripple and Noise (Vrms, 20 Hz to 20 MHz) | 1 mV |
| Constant Current Ripple and Noise (Irms) | 4 mA |
| Common Mode Noise Current (Irms) | 2 mA |
| Common Mode Noise Current (Ip-p) | 10 mA |
Programming Accuracy and Resolution
| Parameter | Value |
|---|---|
| Voltage Programming Accuracy (at 23°C ±5°C) | 0.03% + 12 mV (high range) |
| Current Programming Accuracy (at 23°C ±5°C) | 0.075% + 8 mA |
| Voltage Programming Range | 25 mV - 61.2 V (high range) |
| Current Programming Range | 20 mA - 20.4 A (high range) |
| Voltage Programming Resolution | 4.2 mV (high range) |
| Current Programming Resolution | 2.2 mA |
Readback Accuracy and Resolution
| Parameter | Value |
|---|---|
| Voltage Measurement Resolution (High Range) | 600 µV |
| Current Measurement Resolution (High Range) | 200 µA |
| Current Measurement Resolution (Low Range) | 1 µA |
| Low Measurement Ranges | 200 mA |
Protection Features
| Parameter | Value |
|---|---|
| Over-Voltage Protection (OVP) Maximum Setting | 66 V |
Transient Response and Dynamic Performance
| Parameter | Value |
|---|---|
| Minimum Output Turn-On Delay (Without Relay Option) | 32 ms |
| Minimum Output Turn-On Delay (With Relay Option) | 58 ms |
System Connectivity and Interfaces
| Parameter | Value |
|---|---|
| Remote Sensing Compensation Voltage | Up to 1 V drop per load lead |
| Compatible Mainframes | Keysight N6700 Modular Power System (1U, ATE), Keysight N6705 DC Power Analyzer (Bench) |
Measurement Accuracy
| Parameter | Value |
|---|---|
| Voltage Measurement Accuracy (High Range) | 0.016% + 6 mV |
| Current Measurement Accuracy (High Range) | 0.04% + 4 mA |
| Current Measurement Accuracy (Low Range, 200 mA) | 0.03% + 30 µA |
Protection
| Parameter | Value |
|---|---|
| Over-Voltage Protection (OVP) Accuracy | 0.5% + 0.5 V |
| Over-Voltage Protection (OVP) Response Time | 50 µs |
Output Dynamics
| Parameter | Value |
|---|---|
| Up-programming Rise Time (Full Load) | 1.5 ms |
| Down-programming Fall Time (Full Load) | 1.5 ms |
| Down-programming Fall Time (No Load) | 1.5 ms |
| Transient Response Recovery Time | < 100 µs (to within 75 mV of nominal following a 50% to 100% load change) |
Security & Isolation
| Parameter | Value |
|---|---|
| Maximum Float Voltage | ±240 VDC (from chassis ground) |
Performance
| Parameter | Value |
|---|---|
| Command Processing Time | < 1 ms |
Stability
| Parameter | Value |
|---|---|
| Voltage Output Drift (8 Hours) | 0.02% + 2 mV |
| Current Output Drift (8 Hours) | 0.02% + 1 mA |
Option 2UA Specifications
| Parameter | Value |
|---|---|
| Option 2UA Current Measurement Range | 200 µA |
| Option 2UA Current Measurement Accuracy | 0.5% + 200 nA |
Environmental Specifications
| Parameter | Value |
|---|---|
| Storage Temperature Range | -30 °C to +70 °C |
| Operating Humidity Range | Up to 95% RH (non-condensing) |
| Maximum Operating Altitude | 2000 m |
General Specifications
| Parameter | Value |
|---|---|
| Warm-up Time | 30 minutes |
| Recommended Calibration Cycle | 1 year |
Technology
Precision Programmable Linear-Regulated (Modular)
Applications