The Keysight N9010A EXA Signal Analyzer is an economy-class instrument designed for high throughput on production lines and cost-effective troubleshooting in development and manufacturing. It offers fast and accurate signal analysis capabilities with broad application coverage and modern connectivity.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0, 1000Base-T LAN, GPIB |
| Display | 10.4 inch, XGA (1024x768) color LCD |
| Recommended Calibration Interval | 1 year |
| Environmental Compliance | RoHS compliant, WEEE compliant |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100-240 VAC, 50/60 Hz, 300 W (typical) - 450 W (maximum, option dependent) |
| Operating Temperature | 0 to +55 °C |
| Dimensions (W×H×D) | 426 mm x 177 mm x 472 mm (W x H x D, excluding protrusions) |
| Weight | 19 kg (base unit) |
| Rack Mount Kit | Available |
| Security Slot | Kensington Lock compatible |
Frequency Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 3.6 GHz (N9010A-503 option dependent) |
Amplitude Specifications
| Parameter | Value |
|---|---|
| Absolute Amplitude Accuracy | ±0.27 dB |
| Third Order Intercept (TOI) | +13 dBm |
| Displayed Average Noise Level (DANL) | -146 dBm |
| W-CDMA ACLR Dynamic Range | -73 dBc (with noise correction on) |
Analysis Bandwidth (Vector Signal Analysis)
| Parameter | Value |
|---|---|
| Maximum Analysis Bandwidth | 10 MHz (standard) |
General Characteristics
| Parameter | Value |
|---|---|
| Operating System | Open Windows® XP Professional |
| Internal Storage | 160 GB removable hard drive (shipped after March, 2010) |
| User Interface | Common X-Series user interface |
Options and Accessories
| Parameter | Value |
|---|---|
| Measurement Application Options | LTE, W-CDMA, HSDPA/HSUPA, Phase Noise |
| Measurement Application Software | Agilent 89600 Vector Signal Analysis (VSA) software |
| Data Analysis Software | MATLAB® data analysis software |
| Hardware Option | Fine step attenuator (N9010A-FSA) |
Connectivity
| Parameter | Value |
|---|---|
| LXI Compliance | LXI class C compliant |
| Remote Programming Language Compatibility | SCPI and IVI-COM |
| RF Input Connector | Type N female |
| External Reference Input | 10 MHz, BNC female |
| External Reference Output | 10 MHz, BNC female |
| LAN Interface Speed | 1000Base-T |
| USB Ports | 1x USB 2.0 (front), 5x USB 2.0 (rear) |
| Video Output Ports | DVI-D, DisplayPort |
| GPIB Interface | Standard |
| Trigger Input/Output Connectors | BNC |
Spectrum Analysis
| Parameter | Value |
|---|---|
| Resolution Bandwidth (RBW) | 1 Hz to 8 MHz (standard), 200 Hz, 9 kHz, 120 kHz, 1 MHz (CISPR compliant EMI RBW) |
| Video Bandwidth (VBW) | 1 Hz to 8 MHz |
| Sweep Time | 1 ms to 4000 s |
Performance
| Parameter | Value |
|---|---|
| Phase Noise (10 kHz offset) | -115 dBc/Hz @ 1 GHz (10 kHz offset), -101 dBc/Hz @ 10 GHz (10 kHz offset) |
Input Specifications
| Parameter | Value |
|---|---|
| Maximum Input Level | +30 dBm (with attenuator), +20 dBm (0 dB attenuation) |
| Input Impedance | 50 Ohm |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -40 to +70 °C |
| Humidity | 5% to 95% RH (non-condensing) |
| Altitude | Operating: 4,600 m, Non-operating: 15,300 m |
Compliance
| Parameter | Value |
|---|---|
| EMC Compliance | CISPR 11 / EN 55011 Group 1, Class A, IEC/EN 61326-1 |
| Safety Compliance | IEC/EN 61010-1 |
Internal Architecture
| Parameter | Value |
|---|---|
| Digitizer Resolution | 16-bit |
RF Performance
| Parameter | Value |
|---|---|
| Input Attenuator Range | 0 to 70 dB |
| Input Attenuator Step Size | 10 dB |
| Preamplifier Availability | Option PXX (frequency-dependent) |
| Analysis Bandwidth Options | 25 / 40 / 85 / 160 / 255 MHz (option dependent) |
Measurement Capabilities
| Parameter | Value |
|---|---|
| Detector Types | Peak, Negative Peak, Sample, RMS, Average (Power/Voltage/Log), Quasi-Peak |
| Trace Types | Clear/Write, Max Hold, Min Hold, View, Blank, Average |
Frequency
| Parameter | Value |
|---|---|
| Internal Frequency Reference Accuracy (Standard) | +/- 0.05 ppm |
| Internal Frequency Reference Aging Rate (Standard) | 1 ppm/year |
| Internal Frequency Reference Accuracy (High Stability OCXO Option) | +/- 0.005 ppm |
| Internal Frequency Reference Aging Rate (High Stability OCXO Option) | 0.005 ppm/year |
Power
| Parameter | Value |
|---|---|
| AC Input Voltage Range | 100 - 240 VAC |
| AC Input Frequency Range | 50 / 60 / 400 Hz |
| Power Consumption (Typical) | 250 W |
| Power Consumption (Maximum) | 350 W |
Technology
Signal Analysis
Applications
Manufacturing Test, Wireless Communication Testing, General Purpose RF Analysis, Troubleshooting