The Keysight (formerly Agilent) N9320B is a general-purpose RF spectrum analyzer operating from 9 kHz to 3 GHz. Designed for bench repair, RF education, and R&D applications, it provides essential measurement functions including a standard power suite (channel power, ACP, OBW, SEM, and TOI) alongside SCPI compatibility for automated environments. Equipped with a digital IF, the N9320B resolves fine signal details with a 10 Hz minimum resolution bandwidth and reveals low-level signals with a -148 dBm displayed average noise level (DANL). Optional features such as a 3 GHz tracking generator (Option TG3) and pre-amplifier (Option PA3) further expand its measurement utility.

Specifications

General

ParameterValue
InterfacesUSB Host, USB Device, LAN (10/100Base-T), GPIB (Option G01)
Display6.5-inch TFT color LCD
Warm-up Time45 minutes

Physical

ParameterValue
Power Supply100 to 240 VAC, 50/60 Hz, < 65 W
Operating Temperature5 to 45
Dimensions (W×H×D)320 × 132.5 × 400
Weight7.6

Frequency Specifications

ParameterValue
Frequency Range9 kHz to 3 GHz
Resolution Bandwidth (RBW) Range10 Hz to 1 MHz (1-3-10 sequence)
Video Bandwidth (VBW) Range1 Hz to 1 MHz (1-3-10 sequence)
Internal Reference Frequency10 MHz
Internal Reference Aging Rate±1 ppm / year
Phase Noise (10 kHz Offset)< -90 dBc/Hz (at 1 GHz)

Amplitude Specifications

ParameterValue
Displayed Average Noise Level (DANL) - Preamp On-148 dBm (typical, 10 Hz RBW)
Displayed Average Noise Level (DANL) - Preamp Off-130 dBm (typical, 1 GHz, 10 Hz RBW)
Maximum Safe DC Voltage50 VDC
Absolute Amplitude Accuracy±1.5 dB
Third-Order Intermodulation (TOI)+10 dBm (typical, at 1 GHz)
Input Attenuator Range0 to 70 dB
Input Attenuator Step Size1 dB

Sweep Specifications

ParameterValue
Sweep Time (Span > 0 Hz)10 ms to 1000 s
Minimum Non-Zero Span Sweep Time10 ms

Tracking Generator Specifications (Option)

ParameterValue
Output Frequency Range100 kHz to 3 GHz (Option TG3)
Output Power Level Range-30 dBm to 0 dBm (Option TG3)
Output Power Resolution0.1 dB (Option TG3)

Measurement Features and Options

ParameterValue
Standard Power SuiteChannel Power, ACP, OBW, SEM, TOI
Pre-amplifier Range (Option)1 MHz to 3 GHz (Option PA3)
EMI Filter Bandwidths (Option)200 Hz, 9 kHz, 120 kHz, 1 MHz (Option EMC)
Power Sensor SupportKeysight / Agilent U2000 Series (USB)

Inputs and Outputs

ParameterValue
RF Input Connector TypeType-N Female
RF Input Impedance50 Ω
Tracking Generator Output Connector TypeType-N Female
Tracking Generator Output Impedance50 Ω
10 MHz Reference InputBNC Female
10 MHz Reference OutputBNC Female

General, Physical, and Power

ParameterValue
Display Resolution640 x 480 pixels
Programming LanguageSCPI (ESA-L Series compatible)
Recommended Calibration Cycle1 year

Inputs & Outputs

ParameterValue
External Trigger InputBNC (female), 5 V TTL
Input VSWR< 1.5:1 nominal (10 MHz to 3 GHz, ≥10 dB attenuation)

Performance

ParameterValue
Amplitude RangeDANL to +30 dBm
Number of Traces4
Trace FunctionsClear/write, Maximum hold, Minimum hold, Average
Trigger SourcesFree run, Video, External, Line
Phase Noise (100 kHz Offset)< -100 dBc/Hz (fc = 1 GHz)
Phase Noise (1 MHz Offset)< -110 dBc/Hz (fc = 1 GHz)
Residual Responses< -85 dBm (input terminated, 0 dB attenuation)

Power

ParameterValue
Power Consumption< 25 W

Environmental

ParameterValue
Storage Temperature-20 °C to +70 °C

Frequency

ParameterValue
Span Range0 Hz (zero span), 100 Hz to 3 GHz
Marker Frequency ResolutionSpan / (Sweep points - 1)
Internal Reference Temperature Stability±1 ppm (5 °C to 45 °C)

Sweep

ParameterValue
Sweep Points461
Sweep ModesContinuous, single

Amplitude

ParameterValue
Reference Level Range-100 dBm to +30 dBm
Reference Level Resolution0.1 dB

Tracking Generator (Option TG3)

ParameterValue
Tracking Generator Output Flatness±3 dB (10 MHz to 3 GHz, Option TG3)

Options & Capabilities

ParameterValue
AM/FM Demodulation AnalysisSupported via Option AMA
ASK/FSK Demodulation AnalysisSupported via Option DMA
EMI Filter and Quasi-Peak DetectorSupported via Option EMC

Technology

RF

Applications

Electronics manufacturing, bench repair, RF education, automated test, and R&D projects