The Keysight (formerly Agilent) N9320B is a general-purpose RF spectrum analyzer operating from 9 kHz to 3 GHz. Designed for bench repair, RF education, and R&D applications, it provides essential measurement functions including a standard power suite (channel power, ACP, OBW, SEM, and TOI) alongside SCPI compatibility for automated environments. Equipped with a digital IF, the N9320B resolves fine signal details with a 10 Hz minimum resolution bandwidth and reveals low-level signals with a -148 dBm displayed average noise level (DANL). Optional features such as a 3 GHz tracking generator (Option TG3) and pre-amplifier (Option PA3) further expand its measurement utility.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB Host, USB Device, LAN (10/100Base-T), GPIB (Option G01) |
| Display | 6.5-inch TFT color LCD |
| Warm-up Time | 45 minutes |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 VAC, 50/60 Hz, < 65 W |
| Operating Temperature | 5 to 45 |
| Dimensions (W×H×D) | 320 × 132.5 × 400 |
| Weight | 7.6 |
Frequency Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 3 GHz |
| Resolution Bandwidth (RBW) Range | 10 Hz to 1 MHz (1-3-10 sequence) |
| Video Bandwidth (VBW) Range | 1 Hz to 1 MHz (1-3-10 sequence) |
| Internal Reference Frequency | 10 MHz |
| Internal Reference Aging Rate | ±1 ppm / year |
| Phase Noise (10 kHz Offset) | < -90 dBc/Hz (at 1 GHz) |
Amplitude Specifications
| Parameter | Value |
|---|---|
| Displayed Average Noise Level (DANL) - Preamp On | -148 dBm (typical, 10 Hz RBW) |
| Displayed Average Noise Level (DANL) - Preamp Off | -130 dBm (typical, 1 GHz, 10 Hz RBW) |
| Maximum Safe DC Voltage | 50 VDC |
| Absolute Amplitude Accuracy | ±1.5 dB |
| Third-Order Intermodulation (TOI) | +10 dBm (typical, at 1 GHz) |
| Input Attenuator Range | 0 to 70 dB |
| Input Attenuator Step Size | 1 dB |
Sweep Specifications
| Parameter | Value |
|---|---|
| Sweep Time (Span > 0 Hz) | 10 ms to 1000 s |
| Minimum Non-Zero Span Sweep Time | 10 ms |
Tracking Generator Specifications (Option)
| Parameter | Value |
|---|---|
| Output Frequency Range | 100 kHz to 3 GHz (Option TG3) |
| Output Power Level Range | -30 dBm to 0 dBm (Option TG3) |
| Output Power Resolution | 0.1 dB (Option TG3) |
Measurement Features and Options
| Parameter | Value |
|---|---|
| Standard Power Suite | Channel Power, ACP, OBW, SEM, TOI |
| Pre-amplifier Range (Option) | 1 MHz to 3 GHz (Option PA3) |
| EMI Filter Bandwidths (Option) | 200 Hz, 9 kHz, 120 kHz, 1 MHz (Option EMC) |
| Power Sensor Support | Keysight / Agilent U2000 Series (USB) |
Inputs and Outputs
| Parameter | Value |
|---|---|
| RF Input Connector Type | Type-N Female |
| RF Input Impedance | 50 Ω |
| Tracking Generator Output Connector Type | Type-N Female |
| Tracking Generator Output Impedance | 50 Ω |
| 10 MHz Reference Input | BNC Female |
| 10 MHz Reference Output | BNC Female |
General, Physical, and Power
| Parameter | Value |
|---|---|
| Display Resolution | 640 x 480 pixels |
| Programming Language | SCPI (ESA-L Series compatible) |
| Recommended Calibration Cycle | 1 year |
Inputs & Outputs
| Parameter | Value |
|---|---|
| External Trigger Input | BNC (female), 5 V TTL |
| Input VSWR | < 1.5:1 nominal (10 MHz to 3 GHz, ≥10 dB attenuation) |
Performance
| Parameter | Value |
|---|---|
| Amplitude Range | DANL to +30 dBm |
| Number of Traces | 4 |
| Trace Functions | Clear/write, Maximum hold, Minimum hold, Average |
| Trigger Sources | Free run, Video, External, Line |
| Phase Noise (100 kHz Offset) | < -100 dBc/Hz (fc = 1 GHz) |
| Phase Noise (1 MHz Offset) | < -110 dBc/Hz (fc = 1 GHz) |
| Residual Responses | < -85 dBm (input terminated, 0 dB attenuation) |
Power
| Parameter | Value |
|---|---|
| Power Consumption | < 25 W |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -20 °C to +70 °C |
Frequency
| Parameter | Value |
|---|---|
| Span Range | 0 Hz (zero span), 100 Hz to 3 GHz |
| Marker Frequency Resolution | Span / (Sweep points - 1) |
| Internal Reference Temperature Stability | ±1 ppm (5 °C to 45 °C) |
Sweep
| Parameter | Value |
|---|---|
| Sweep Points | 461 |
| Sweep Modes | Continuous, single |
Amplitude
| Parameter | Value |
|---|---|
| Reference Level Range | -100 dBm to +30 dBm |
| Reference Level Resolution | 0.1 dB |
Tracking Generator (Option TG3)
| Parameter | Value |
|---|---|
| Tracking Generator Output Flatness | ±3 dB (10 MHz to 3 GHz, Option TG3) |
Options & Capabilities
| Parameter | Value |
|---|---|
| AM/FM Demodulation Analysis | Supported via Option AMA |
| ASK/FSK Demodulation Analysis | Supported via Option DMA |
| EMI Filter and Quasi-Peak Detector | Supported via Option EMC |
Technology
RF
Applications
Electronics manufacturing, bench repair, RF education, automated test, and R&D projects