- Home
- Categories
- Test equipment
- Power Supplies
- Agilent HP
- U8000 Series - 90-150W
The Keysight Technologies (formerly Agilent) U8000 Series comprises the U8001A (90W) and U8002A (150W) single-output, non-programmable DC power supplies. Offering outstanding load and line regulation, fast transient response, low output noise, and integrated overvoltage and overcurrent protection, these reliable benchtop power supplies deliver the capabilities and security of programmable power supplies at an affordable price point.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | None (Non-programmable; features Kensington security lock slot for physical security) |
| Display | LCD with backlight on/off options |
| Standard Included Accessories | Power cord, Quick Reference Guide, Product Reference CD-ROM, Certificate of Calibration |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 °C to 40 °C |
| Weight | 7.3 kg (U8001A) / 8.3 kg (U8002A) |
| Output Terminal Type | Front panel binding posts |
Output Specifications
| Parameter | Value |
|---|---|
| Number of Outputs | 1 |
| DC Output Voltage Range | 0 V to 30 V |
| U8001A DC Output Current Range | 0 A to 3 A |
| U8002A DC Output Current Range | 0 A to 5 A |
| U8001A Maximum Output Power | 90 W |
| U8002A Maximum Output Power | 150 W |
Programming and Readback Accuracy
| Parameter | Value |
|---|---|
| Voltage Programming Accuracy | < 0.35% + 20 mV (at 25 °C ± 5 °C) |
| U8001A Current Programming Accuracy | < 0.35% + 15 mA (at 25 °C ± 5 °C) |
| U8002A Current Programming Accuracy | < 0.35% + 20 mA (at 25 °C ± 5 °C) |
| Voltage Readback Accuracy | < 0.35% + 20 mV (at 25 °C ± 5 °C) |
| U8001A Current Readback Accuracy | < 0.35% + 15 mA (at 25 °C ± 5 °C) |
| U8002A Current Readback Accuracy | < 0.35% + 20 mA (at 25 °C ± 5 °C) |
Programming and Readback Resolution
| Parameter | Value |
|---|---|
| Voltage Programming Resolution | 10 mV |
| Current Programming Resolution | 10 mA |
| Voltage Readback Resolution | 10 mV |
| Current Readback Resolution | 10 mA |
| Voltage Meter Resolution | 10 mV |
| Current Meter Resolution | 10 mA |
Transient Response
| Parameter | Value |
|---|---|
| Transient Recovery Time | < 50 µs |
| Transient Load Change Amplitude | 50% to 100% of full load |
| Transient Settling Band | Within 15 mV of nominal value |
Protection Features
| Parameter | Value |
|---|---|
| Overvoltage Protection (OVP) Range | 1 V to 33 V |
| Overvoltage Protection Accuracy | < 0.5% + 0.5 V |
User Interface and Controls
| Parameter | Value |
|---|---|
| Save/Recall Memory States | 3 memory states |
| Keylock Security Feature | Yes (prevents accidental front-panel changes) |
| Output On/Off Switch | Yes |
Power Input Requirements
| Parameter | Value |
|---|---|
| AC Input Voltage Settings | 100 Vac / 115 Vac / 230 Vac (± 10% tolerance, switch-selectable) |
| AC Input Frequency Range | 47 Hz to 63 Hz |
| U8001A Fuse Rating | T4.0 AL / 250 V (100/115 Vac) or T2.0 AL / 250 V (230 Vac) |
| U8002A Fuse Rating | T6.3 AL / 250 V (100/115 Vac) or T3.15 AL / 250 V (230 Vac) |
Environmental Conditions
| Parameter | Value |
|---|---|
| Storage Temperature Range | -20 °C to 70 °C |
| Operating Humidity Range | Up to 80% RH (non-condensing) at 40 °C |
| Operating Altitude | Up to 2000 meters |
| Cooling Mechanism | Forced air cooling (internal fan) |
| Installation Category | CAT II |
| Pollution Degree | Pollution Degree 2 |
Physical and Mechanical
| Parameter | Value |
|---|---|
| Width (without bumpers) | 212.3 mm |
| Width (with bumpers) | 230.0 mm |
| Height (without bumpers) | 88.1 mm (2U) |
| Height (with bumpers) | 104.2 mm |
| U8001A Net Weight | 7.3 kg |
| U8002A Net Weight | 8.3 kg |
| Rackmount Form Factor Compatibility | Yes (with standard rackmount kits) |
Compliance and Safety
| Parameter | Value |
|---|---|
| Safety Standard Certifications | CSA C22.2 No. 61010-1, UL 61010-1 |
| Electromagnetic Compatibility (EMC) | CE, C-tick (EN61326-1, ICES-001) |
| Recommended Calibration Cycle | 1 year |
Performance
| Parameter | Value |
|---|---|
| Maximum Output Float Voltage | ±240 Vdc |
Technology
Linear
Applications