The Keysight Technologies (formerly Agilent) U8000 Series comprises the U8001A (90W) and U8002A (150W) single-output, non-programmable DC power supplies. Offering outstanding load and line regulation, fast transient response, low output noise, and integrated overvoltage and overcurrent protection, these reliable benchtop power supplies deliver the capabilities and security of programmable power supplies at an affordable price point.

Specifications

General

ParameterValue
InterfacesNone (Non-programmable; features Kensington security lock slot for physical security)
DisplayLCD with backlight on/off options
Standard Included AccessoriesPower cord, Quick Reference Guide, Product Reference CD-ROM, Certificate of Calibration

Physical

ParameterValue
Operating Temperature0 °C to 40 °C
Weight7.3 kg (U8001A) / 8.3 kg (U8002A)
Output Terminal TypeFront panel binding posts

Output Specifications

ParameterValue
Number of Outputs1
DC Output Voltage Range0 V to 30 V
U8001A DC Output Current Range0 A to 3 A
U8002A DC Output Current Range0 A to 5 A
U8001A Maximum Output Power90 W
U8002A Maximum Output Power150 W

Programming and Readback Accuracy

ParameterValue
Voltage Programming Accuracy< 0.35% + 20 mV (at 25 °C ± 5 °C)
U8001A Current Programming Accuracy< 0.35% + 15 mA (at 25 °C ± 5 °C)
U8002A Current Programming Accuracy< 0.35% + 20 mA (at 25 °C ± 5 °C)
Voltage Readback Accuracy< 0.35% + 20 mV (at 25 °C ± 5 °C)
U8001A Current Readback Accuracy< 0.35% + 15 mA (at 25 °C ± 5 °C)
U8002A Current Readback Accuracy< 0.35% + 20 mA (at 25 °C ± 5 °C)

Programming and Readback Resolution

ParameterValue
Voltage Programming Resolution10 mV
Current Programming Resolution10 mA
Voltage Readback Resolution10 mV
Current Readback Resolution10 mA
Voltage Meter Resolution10 mV
Current Meter Resolution10 mA

Transient Response

ParameterValue
Transient Recovery Time< 50 µs
Transient Load Change Amplitude50% to 100% of full load
Transient Settling BandWithin 15 mV of nominal value

Protection Features

ParameterValue
Overvoltage Protection (OVP) Range1 V to 33 V
Overvoltage Protection Accuracy< 0.5% + 0.5 V

User Interface and Controls

ParameterValue
Save/Recall Memory States3 memory states
Keylock Security FeatureYes (prevents accidental front-panel changes)
Output On/Off SwitchYes

Power Input Requirements

ParameterValue
AC Input Voltage Settings100 Vac / 115 Vac / 230 Vac (± 10% tolerance, switch-selectable)
AC Input Frequency Range47 Hz to 63 Hz
U8001A Fuse RatingT4.0 AL / 250 V (100/115 Vac) or T2.0 AL / 250 V (230 Vac)
U8002A Fuse RatingT6.3 AL / 250 V (100/115 Vac) or T3.15 AL / 250 V (230 Vac)

Environmental Conditions

ParameterValue
Storage Temperature Range-20 °C to 70 °C
Operating Humidity RangeUp to 80% RH (non-condensing) at 40 °C
Operating AltitudeUp to 2000 meters
Cooling MechanismForced air cooling (internal fan)
Installation CategoryCAT II
Pollution DegreePollution Degree 2

Physical and Mechanical

ParameterValue
Width (without bumpers)212.3 mm
Width (with bumpers)230.0 mm
Height (without bumpers)88.1 mm (2U)
Height (with bumpers)104.2 mm
U8001A Net Weight7.3 kg
U8002A Net Weight8.3 kg
Rackmount Form Factor CompatibilityYes (with standard rackmount kits)

Compliance and Safety

ParameterValue
Safety Standard CertificationsCSA C22.2 No. 61010-1, UL 61010-1
Electromagnetic Compatibility (EMC)CE, C-tick (EN61326-1, ICES-001)
Recommended Calibration Cycle1 year

Performance

ParameterValue
Maximum Output Float Voltage±240 Vdc

Technology

Linear

Applications

Benchtop DC Power Supply