The Keysight AC6803B is a basic programmable AC power source offering up to 2000 VA of AC power and 1600 W of DC power. Designed for utility fluctuation simulation and power testing, it features a complete set of measurement capabilities, including RMS voltage, current, power, and harmonic analysis, combined with a user-friendly interface and modern connectivity.

Specifications

General

ParameterValue
InterfacesUSB, LAN (LXI Core); Optional GPIB (via AC68GPBU interface card)
DisplayGraphical LCD with backlight

Physical

ParameterValue
Power Supply180 to 264 VAC, single-phase, 47 to 63 Hz
Operating Temperature0 to 50 °C
Dimensions (W×H×D)428 mm × 128 mm × 447 mm
Weight24.0

AC Output Specifications

ParameterValue
Maximum AC Power Rating2000 VA
Output Phase ConfigurationSingle-phase
AC Voltage Ranges1 to 135 Vrms / 2 to 270 Vrms
AC Voltage Resolution0.1 V
Frequency Range40 Hz to 500 Hz
Maximum RMS Current (135 V Range)20 A
Maximum RMS Current (270 V Range)10 A
Maximum Peak Current (135 V Range)60 A
Maximum Peak Current (270 V Range)30 A
Total Harmonic Distortion (THD)≤ 0.5% (at 40 to 100 Hz), ≤ 1.0% (at 100 to 500 Hz)

DC Output Specifications

ParameterValue
Maximum DC Power Rating1600 W
DC Voltage Ranges1.4 to 190 V / 2.8 to 380 V
Maximum DC Current (190 V Range)16 A
Maximum DC Current (380 V Range)8 A

Physical & Environmental Specifications

ParameterValue
Rack Height Units (U)3U
Cooling MethodForced air cooling (front intake, rear exhaust)

Input Ratings

ParameterValue
Input Voltage Range180 VAC to 264 VAC
Input Frequency Range47 Hz to 63 Hz
Input Phase ConfigurationSingle-phase
Maximum Input Apparent Power3400 VA

Performance

ParameterValue
Load Regulation (135 V Range)≤ 0.15 V (for 0% to 100% load change)
Load Regulation (270 V Range)≤ 0.3 V (for 0% to 100% load change)
Line Regulation≤ 0.1% (for input voltage variations over the operating range)
AC Voltage Setting Accuracy (135 V Range)±(0.5% of setting + 0.6 V) at 23 °C ± 5 °C
AC Voltage Setting Accuracy (270 V Range)±(0.5% of setting + 1.2 V) at 23 °C ± 5 °C
Frequency Setting Accuracy±0.02%

Measurement

ParameterValue
RMS Voltage Measurement Accuracy (135 V Range)±(0.5% of reading + 0.6 V)
RMS Voltage Measurement Accuracy (270 V Range)±(0.5% of reading + 1.2 V)
Voltage Measurement Resolution0.1 V

Programming & Control

ParameterValue
Setup Memory Capacity10 states
Programming LanguageSCPI
Optional Interface CardsAC68GPBU (GPIB), AC68ALGU (Analog)

Environmental

ParameterValue
Storage Temperature Range-10 °C to 60 °C
Operating Humidity Range20% to 80% RH (non-condensing)
Storage Humidity Range20% to 80% RH (non-condensing)
Maximum Operating Altitude2000 m

Measurement Accuracy

ParameterValue
RMS Current Measurement Accuracy (135 V Range)±(0.5% of reading + 0.2 A)
RMS Current Measurement Accuracy (270 V Range)±(0.5% of reading + 0.1 A)
Peak Current Measurement Accuracy (135 V Range)±(2% of reading + 2 A)
Peak Current Measurement Accuracy (270 V Range)±(2% of reading + 1 A)
Active Power Measurement Accuracy (135 V Range)±(1.5% of reading + 6 W)
Active Power Measurement Accuracy (270 V Range)±(1.5% of reading + 6 W)
Apparent Power Measurement Accuracy (135 V Range)±(2% of reading + 12 VA)
Apparent Power Measurement Accuracy (270 V Range)±(2% of reading + 12 VA)
DC Voltage Measurement Accuracy (190 V Range)±(0.1% of reading + 0.2 V)
DC Voltage Measurement Accuracy (380 V Range)±(0.1% of reading + 0.4 V)
Frequency Measurement Accuracy±0.1 Hz (for 40.0 Hz to 500.0 Hz)

Output Accuracy

ParameterValue
DC Voltage Setting Accuracy (190 V Range)±(0.1% of setting + 0.2 V)
DC Voltage Setting Accuracy (380 V Range)±(0.1% of setting + 0.4 V)

Measurement Resolution

ParameterValue
Crest Factor Measurement Resolution0.01

Output Characteristics

ParameterValue
Output Voltage WaveformSine wave
Transient Response Time150 μs (typical, for 0% to 100% or 100% to 0% load change)

Technology

AC/DC Power Source

Applications

AC power simulation, power supply testing, frequency conversion, and harmonic analysis