The Rohde & Schwarz CMD57 is a digital radiocommunication tester tailored for comprehensive measurements on GSM base stations (BTS) and BTS modules. Supporting GSM900, E-GSM, and UIC, with optional support for GSM1800 and GSM1900, it provides high-precision transmitter and receiver testing without disrupting active telephone calls.

Specifications

General

ParameterValue
InterfacesRS-232-C, IEC/IEEE-488 (GPIB)
DisplayLCD display with softkeys on both sides

Physical

ParameterValue
Power Supply100 V to 240 V AC (±10%), 50 Hz to 60 Hz / 400 Hz
Operating Temperature5 °C to 45 °C
Dimensions (W×H×D)435 mm × 170 mm × 415 mm

Protocol & Call Processing

ParameterValue
Supported GSM BandsGSM900, E-GSM, UIC (European train radiotelephony), GSM1800 (optional), GSM1900 (optional)
Bit Error Rate (BER) Measurement InterfacesAbis interface, IEEE bus, RS-232-C interface, BTS loopback, CMD loopback

RF Analyzer (Receiver & Transmitter Testing)

ParameterValue
Dynamic Range>72 dB (for checking power ramps and output spectrum)
Adjacent Timeslot RejectionUp to 50 dB higher level (for BTS AGC testing)
Transmitter Power Ramp MeasurementChecking switching characteristics of BTS transmitter
Phase and Frequency Error MeasurementTesting modulation characteristics including statistical function
Spectrum MeasurementsSpectrum measurement due to modulation or switching
RF Monitor Bandwidths30 kHz and 100 kHz (replaces external spectrum analyzer)
Module Test FunctionalityComplete transmitter measurements without signaling or time synchronization

RF Signal Generator (Transmitter Simulation)

ParameterValue
Multifunction RF GeneratorIntegrated for receiver module alignment

Connectivity & Interfaces

ParameterValue
Remote Control ProtocolSCPI-compatible remote control
Software Update MethodSimple download via the RS-232-C interface

RF Connections

ParameterValue
RF Input/Output Impedance50 Ω
Main RF Connector TypeN-type (female)
Auxiliary RF ConnectorsBNC (female)
Reference Frequency Input/Output10 MHz, BNC

RF Analyzer

ParameterValue
Max RF Input Power (RF IN/OUT)+47 dBm (GSM peak power)

Reference Oscillator

ParameterValue
Reference Oscillator Frequency10 MHz
Reference Oven OptionCMD-B1 (OCXO)

GSM Features

ParameterValue
Supported Speech CodecsFull Rate (FR), Enhanced Full Rate (EFR), Half Rate (HR)
GSM Phase SupportPhase 1, Phase 2, Phase 2+

Transmitter Measurements

ParameterValue
Peak Power Measurement Range0 dBm to +47 dBm
Peak Power Measurement Accuracy< 0.6 dB (GSM900), < 0.9 dB (DCS1800/PCS1900)

Receiver Measurements

ParameterValue
RF Generator Output Level Range (RF IN/OUT)-33 dBm to -120 dBm

Technology

GSM

Applications

Base station (BTS) and BTS module testing

Looking for the Rohde & Schwarz CMD57?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us