The Rohde & Schwarz FSH18 is a handheld, battery-powered spectrum analyzer designed for microwave applications in the field. Operating from 10 MHz up to 18 GHz, it is ideal for servicing microwave links, field strength measurements, and signal monitoring.

Specifications

General

ParameterValue
InterfacesOptical RS-232, USB (via optical-to-USB adapter cable)
Display4.7" color LCD, 320 × 240 pixels
Internal Setup and Trace MemoryUp to 100 configurations and traces
Warm-up Time20 min

Physical

ParameterValue
Power Supply100 V to 240 V AC (50/60 Hz) external adapter, 15 V DC input, typ. 7 W
Operating Temperature0 to 50
Dimensions (W×H×D)129 mm × 283 mm × 115 mm
Weight2.5

Frequency Specifications

ParameterValue
Frequency Range10 MHz to 18 GHz
Frequency Resolution1 Hz
Reference Frequency Accuracy2 ppm
Reference Frequency Temperature Drift2 ppm (0 °C to 50 °C)
Reference Frequency Aging2 ppm/year
Frequency Span Range0 Hz, 10 kHz to 18 GHz
Spectral Purity (Phase Noise)<-100 dBc/Hz @ 100 kHz offset (typ.)

Sweep and Trigger

ParameterValue
Sweep Time (Span >= 10 kHz)100 ms to 1000 s
Sweep Time (Zero Span)1 ms to 100 s
Sweep Trigger SourceFree Run, External, Video
Trigger Delay Range125 µs to 125 s (Zero Span)
Sweep ModesContinuous, Single
Number of Sweep Points301

Bandwidths

ParameterValue
Resolution Bandwidths (RBW) Range100 Hz to 1 MHz
Resolution Bandwidths (RBW) Steps1 and 3 steps
Video Bandwidths (VBW) Range10 Hz to 1 MHz
Video Bandwidths (VBW) Steps1 and 3 steps
Resolution Filter Shape Factor< 5 (60 dB / 3 dB bandwidth)

Amplitude and Noise

ParameterValue
Displayed Average Noise Level (DANL) (3 GHz to 6 GHz)typ. -128 dBm (RBW 100 Hz)
Displayed Average Noise Level (DANL) (100 MHz to 3 GHz)typ. -128 dBm (RBW 100 Hz)
Displayed Average Noise Level (DANL) (6 GHz to 18 GHz)typ. -120 dBm (RBW 100 Hz)
Maximum Safe RF Input Power+20 dBm (continuous)
Maximum Safe RF Input Power (Short Term)+30 dBm (< 3 s)
Maximum DC Input Voltage80 V
Input Attenuator Range0 dB to 30 dB (in 10 dB steps)

Measurement Accuracy

ParameterValue
Level Accuracy (6 GHz to 18 GHz)2.5 dB
RF Input VSWR (10 MHz to 6 GHz)typ. < 1.5
RF Input VSWR (6 GHz to 18 GHz)typ. < 2.0
Reference Level Range-80 dBm to +20 dBm
Reference Level Steps1 dB or 10 dB

Measurement Modes and Functions

ParameterValue
Standard Measurement TypesChannel power, Occupied bandwidth (OBW), TDMA power, C/N ratio, Spectrum emission mask
Marker FunctionsPeak, Next Peak, Minimum, Center Frequency, Reference Level, Noise Marker, Frequency Counter
Number of Markers1 normal marker and up to 5 delta markers
Detector TypesSample, Max Peak, Min Peak, Auto Peak, RMS
Trace FunctionsClear/Write, Max Hold, Min Hold, Average, View
Limit Lines SupportUpper and lower limit lines with Pass/Fail indication

Connectivity and Interfaces

ParameterValue
RF Input ConnectorN female
RF Input Impedance50 Ω
External Trigger / Reference InputBNC female (shared)
Audio Output Port3.5 mm jack for headphones

Power and Battery

ParameterValue
Battery TypeLithium-ion battery
Battery Charging Timeapprox. 4 h (instrument off)

Physical Characteristics

ParameterValue
Width194 mm
Height300 mm
Depth144 mm
Portability FeaturesHand strap, integrated kickstand
Chassis MaterialRobust plastic housing with shock-absorbing corners

Environmental Specifications

ParameterValue
Relative Humidity Range95% (non-condensing)
IP RatingIP51

Compliance and Standards

ParameterValue
EMC ComplianceEN 61326-1, EN 55011 Class B
Electrical Safety StandardsEN 61010-1
Calibration Interval1 year (recommended)

Performance

ParameterValue
Third-Order Intercept (TOI)+10 dBm (typ. +15 dBm) at 1 GHz
SSB Phase Noise (100 kHz offset)<-95 dBc/Hz (typ. -105 dBc/Hz) at 500 MHz
SSB Phase Noise (1 MHz offset)<-115 dBc/Hz (typ. -125 dBc/Hz) at 500 MHz
Number of Traces2 (1 active trace, 1 memory trace)

Power

ParameterValue
Power Consumption12 W
External Power Adapter AC Input100 V to 240 V AC, 50 Hz to 60 Hz
External DC Input Voltage Range15 V to 20 V DC

Interfaces

ParameterValue
GPS Receiver InterfaceSupports external R&S HA-Z240 GPS receiver via USB

Frequency

ParameterValue
External Reference Input Frequency10 MHz

Inputs & Outputs

ParameterValue
External Trigger Input LevelTTL level

Expansion & Accessories

ParameterValue
Power Sensor CompatibilityR&S FSH-Z1 (10 MHz to 8 GHz), R&S FSH-Z18 (10 MHz to 18 GHz)

Environmental

ParameterValue
Environmental Resistance (Vibration)Meets MIL-PRF-28800F Class 3
Environmental Resistance (Shock)Meets MIL-PRF-28800F Class 3

Technology

Superheterodyne Spectrum Analyzer

Applications

Microwave link servicing, field strength measurements, and signal monitoring