The Rohde & Schwarz NRP-Z11 is a high-precision three-path diode power sensor designed for continuous average, burst average, and timeslot average power measurements. Operating across a frequency range of 10 MHz to 8 GHz and a 90 dB dynamic range from -67 dBm to +23 dBm, it provides exceptionally low measurement uncertainty and excellent SWR for RF and microwave applications.

Specifications

General

ParameterValue
InterfacesProprietary R&S 12-pin host interface (supports USB connection via NRP-Z3 or NRP-Z4 adapter)

Physical

ParameterValue
Power Supply5 V DC (supplied via host instrument or USB adapter), typical current 120 mA
Operating Temperature0 °C to +50 °C
Dimensions (W×H×D)48 mm × 30 mm × 137 mm

Measurement Ranges & Power Specifications

ParameterValue
Frequency Range Minimum10 MHz
Frequency Range Maximum8 GHz
Power Measurement Range Minimum-67 dBm
Power Measurement Range Maximum+23 dBm
Maximum Continuous Input Power+26 dBm (400 mW)
Maximum Peak Input Power+40 dBm (10 W)
Maximum Peak Input Power Duration< 10 µs
Maximum DC Input Voltage20 V
Dynamic Range90 dB

Sensor Technology & Architecture

ParameterValue
Sensor Detection TypeThree-path diode sensor
Measurement Modes SupportedContinuous Average, Burst Average, Timeslot Average

RF Port Characteristics

ParameterValue
Input Impedance50 Ω
RF Connector TypeN
Connector SexMale
Maximum SWR (10 MHz to 2.4 GHz)≤ 1.11
Maximum SWR (2.4 GHz to 8 GHz)≤ 1.16

Accuracy, Calibration & Noise

ParameterValue
Zero Set50 pW

Meter Compatibility & System Integration

ParameterValue
Recommended Calibration Cycle1 year

Physical Dimensions & Weight

ParameterValue
Cable Length1.5 m (integrated)

Environmental Parameters

ParameterValue
Storage Temperature Range-40 °C to +70 °C

Performance

ParameterValue
Measurement SpeedUp to 1500 measurements/s (buffered mode)
Rise Time< 13 µs
Video Bandwidth> 20 kHz
Zero Drift< 15 pW (within 1 hour after zeroing at constant temperature)
Measurement Noise< 25 pW (aperture time 100 ms, 2 sigma)
Calibration Uncertainty1.3% to 2.0% (frequency dependent)
Calibration Data StorageInternal EEPROM
Path Crossover Levels-20 dBm, 0 dBm
Maximum Measurement Rateup to 1500 measurements/s (buffered average mode)

Power

ParameterValue
Current Consumption120 mA (typical at 5 V)
Power Consumption0.6 W

Functionality

ParameterValue
Trigger SourcesInternal, External (via Host or Adapter)

Environmental

ParameterValue
Relative Humidity (Operating)Up to 95% at +30 °C (non-condensing)
Operating Altitudeup to 4600 m
Shock Resistance45 g shock spectrum, compliant with MIL-STD-810F (Method 516.5, Proc. I)
Sinusoidal Vibration5 Hz to 55 Hz, 0.15 mm amplitude; 55 Hz to 150 Hz, 0.5 g, compliant with EN 60068-2-6
Random Vibration10 Hz to 500 Hz, 1.9 g (rms), compliant with EN 60068-2-64

Standards & Compliance

ParameterValue
Electrical SafetyCompliant with EN 61010-1
EMC ComplianceCompliant with EN 61326-1 (Class B), EN 61326-2-1, EN 55011 (Group 1, Class B)

Technology

Three-path diode

Applications

RF and Microwave Power Measurement