The Rohde & Schwarz NRVD is a highly accurate, dual-channel RF power meter designed for precise power and voltage measurements. Featuring two independent channels, the NRVD supports simultaneous dual-channel measurements with real-time computations like ratio (A/B, B/A) and difference (A-B, B-A). With a vast compatibility library of smart, plug-and-play sensors, it covers a wide dynamic range and frequency spectrum up to 40 GHz. Its backlit LCD, menu-driven softkey interface, and integrated sensor check source make it an industry-standard bench and system instrument.
Specifications
General
| Parameter | Value |
|---|---|
| Display | Backlit LCD with variable backlighting, two separate digital readouts, and dual bargraph indicators |
Measurement Performance
| Parameter | Value |
|---|---|
| Frequency Range | 0 Hz (DC) to 40 GHz (sensor dependent) |
| Measurement Channels | 2 independent channels |
| Display Resolution (Logarithmic) | 0.001 dB / 0.01 dB / 0.1 dB (selectable) |
| Display Resolution (Linear) | 4.5 digits max |
| Calibration Factor Entry | Automatic readout from sensor EEPROM or manual entry |
Measurement Modes & Functions
| Parameter | Value |
|---|---|
| Measurement Modes | A, B, A/B, B/A, A-B, B-A, SWR, Return Loss, Reflection Coefficient |
| Absolute Measurement Units | W, dBm, V, dBµV |
| Range Selection | Automatic or manual |
| Noise Suppression Filters | 13 digital filters (averaging factor 1 to 4096, automatic or manual selection) |
| Averaging Factors | 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 |
Sensor Check Source
| Parameter | Value |
|---|---|
| Reference Frequency | 50 MHz |
| Reference Power Level | 1.00 mW (0 dBm) |
| Calibration Output VSWR | ≤ 1.05 |
| Reference Output Connector | N female (front panel) |
| Output Impedance | 50 Ω |
Sensor Compatibility
| Parameter | Value |
|---|---|
| Compatible Sensors | R&S URV5-Z and NRV-Z series (thermal, diode, peak power, voltage probes) |
| Sensor Input Connectors | 2 × 12-pin circular connectors (front panel; rear panel optionally) |
| Sensor Detection Type | Plug and Play (automatic readout of calibration and sensor data) |
| Calibration Data Storage Support | Yes, built-in non-volatile memory (EEPROM) in sensors |
Interfaces & I/O
| Parameter | Value |
|---|---|
| GPIB Interface Standard | IEEE 488 / IEC 625-1 |
| GPIB Remote Command Set | SCPI or URV5-compatible mode |
| Analog Output Resolution (Option NRVD-B1) | 12-bit (approx. 1 mV) |
| Analog Output Load (Option NRVD-B1) | ≥ 10 kΩ |
| External Trigger Input (Option NRVD-B1) | TTL level, minimum pulse width 10 µs, BNC connector |
| Ready Output (Option NRVD-B1) | TTL level, BNC connector |
System & Control
| Parameter | Value |
|---|---|
| Store/Recall Memory | 20 complete setups |
| Self-Test Function | Automatic self-test upon power-on |
Power Requirements
| Parameter | Value |
|---|---|
| AC Input Voltage Range | 100 V / 120 V / 220 V / 240 V (±10%, selectable) |
| AC Input Frequency Range | 47 Hz to 440 Hz |
Physical & Environmental
| Parameter | Value |
|---|---|
| Width | 219 mm |
| Height | 103 mm |
| Depth | 350 mm |
| Storage Temperature Range | -40 °C to +70 °C |
| Electrical Safety Compliance | EN 61010-1 / IEC 1010-1 |
| Display Type | Liquid Crystal Display (LCD) |
Storage & Setup
| Parameter | Value |
|---|---|
| Stored Instrument Setups Capacity | 20 complete setups |
System Options
| Parameter | Value |
|---|---|
| Rear-Panel Sensor Inputs Option | Option NRVD-B2 (relocates sensor connectors A and B to rear panel) |
Option NRVD-B1 Interface Details
| Parameter | Value |
|---|---|
| Option NRVD-B1 Analog Output Voltage Range | 0 V to 3 V |
| Option NRVD-B1 Analog Frequency Input Voltage Range | 0 V to 10 V |
| Option NRVD-B1 External Trigger Input Signal Level | TTL level |
| Option NRVD-B1 Ready Output Signal Level | TTL level |
GPIB Interface
| Parameter | Value |
|---|---|
| GPIB Address Range | 0 to 30 |
Standards & Compliance
| Parameter | Value |
|---|---|
| EMC Emission Standards | EN 55011 Class B, VDE 0871 Class B |
| EMC Immunity Standards | EN 50082-1 |
Compliance
| Parameter | Value |
|---|---|
| Safety Class | Class I (IEC 348 / VDE 0411) |
Display
| Parameter | Value |
|---|---|
| Analog Display Type | Two bargraphs with selectable scaling |
Technology
RF Power Meter
Applications
RF and Microwave Power Measurement