- Home
- Categories
- Test equipment
- Oscilloscopes
- *misc
- RTO64 (1802.0001.04)
The Rohde & Schwarz RTO64 (order code 1802.0001.04) is a high-performance 4-channel digital oscilloscope featuring a 600 MHz base analog bandwidth, a 10-bit vertical resolution, and a brilliant 15.6-inch Full HD capacitive touchscreen. Designed for complex multi-domain debugging and high-speed signal analysis, it provides up to 10 GSa/s sample rate per channel and an exceptional acquisition rate of up to 1 million waveforms per second.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | 4x USB 3.1 Gen 1, 2x USB 2.0, 1x USB 3.1 Gen 1 Device, 1x LAN (10/100/1000BASE-T), 1x HDMI, 1x DisplayPort, GPIB (optional) |
| Display | 15.6-inch TFT capacitive color touchscreen, 1920 × 1080 resolution (Full HD) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 V to 240 V AC (±10%) at 50 Hz to 60 Hz or 400 Hz, max. 450 W |
| Operating Temperature | 0 °C to +45 °C |
| Dimensions (W×H×D) | 450 mm × 311 mm × 211 mm |
| Weight | 13.0 kg |
Vertical System
| Parameter | Value |
|---|---|
| Analog Bandwidth (-3 dB) | 600 MHz (base model, software upgradable up to 6 GHz) |
| Number of Input Channels | 4 analog channels |
| Vertical Resolution | 10-bit (up to 16-bit in HD mode) |
| Calculated Rise Time (10% to 90%) | < 583 ps |
| Input Impedance | 50 Ω ± 1.5%, 1 MΩ ± 1% || 12 pF (typ.) |
| Input Coupling | 1 MΩ: AC, DC; 50 Ω: DC |
| Input Sensitivity Range (50 Ω) | 500 µV/div to 1 V/div |
| Input Sensitivity Range (1 MΩ) | 500 µV/div to 10 V/div |
| Maximum Input Voltage (50 Ω) | 5 V RMS, max. peak 30 V |
| Maximum Input Voltage (1 MΩ) | 300 V RMS, CAT I |
| DC Gain Accuracy | ±1% of full scale for ≥ 5 mV/div |
| A/D Converter Resolution | 10-bit (up to 16-bit in HD mode) |
Horizontal System
| Parameter | Value |
|---|---|
| Timebase Range | 25 ps/div to 10000 s/div |
| Timebase Accuracy | ±100 ppb (standard TCXO), ±20 ppb (with RTO6-B4 OCXO option) |
| Channel-to-Channel Deskew Range | ±100 ns |
| Timebase Temperature Stability | ±0.1 ppm (±0.02 ppm with RTO6-B4 OCXO option) |
| Timebase Aging | ±1 ppm per year (±0.02 ppm per year with RTO6-B4 OCXO option) |
Acquisition System
| Parameter | Value |
|---|---|
| Maximum Real-Time Sample Rate | 10 GSa/s per channel (4 channels), 20 GSa/s (2 channels interleaved) |
| Maximum Record Length (Standard) | 200 Mpoints per channel (4 channels), 400 Mpoints (interleaved) |
| Maximum Record Length (Optional) | Up to 1 Gpoints per channel (2 Gpoints interleaved) |
| Waveform Capture Rate | Up to 1,000,000 waveforms/s |
| Acquisition Modes | Sample, Peak Detect, Envelope, Average, High Resolution (HD) |
| History Segment Memory | Up to 1,000,000 segments (standard) |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Sources | Analog channels 1 to 4, External Trigger, Line (Mains) |
| Trigger Modes | Auto, Normal, Single |
| Trigger Coupling | DC, AC, HF Reject, LF Reject, Noise Reject |
| Standard Trigger Types | Edge, Glitch, Width, Runt, Window, Timeout, Interval, Slew Rate, Setup & Hold, Pattern, State |
| Advanced Trigger Types | Zone Trigger, Serial Bus Trigger (with options) |
| Trigger Jitter | typ. < 1 ps RMS |
| Trigger Level Range | ±5 div from screen center |
| Trigger Hysteresis | Automatic or adjustable (0 div to 5 div) |
Waveform Measurements and Analysis
| Parameter | Value |
|---|---|
| Automatic Measurements | Up to 31 measurements simultaneously |
| Measurement Statistics | Mean, Min, Max, Standard Deviation, Count |
| Waveform Math Operators | +, -, *, /, Integration, Differentiation, FFT, Log, Absolute, Square, Square Root, Sine, Cosine |
| FFT Window Types | Hanning, Hamming, Blackman, Rectangular, Flat Top |
| FFT Maximum Points | Up to 8 Mpoints (standard), up to 64 Mpoints (optional) |
Display and User Interface
| Parameter | Value |
|---|---|
| Waveform Display Formats | YT, XY, XYZ |
Connectivity and Interfaces
| Parameter | Value |
|---|---|
| External Trigger Input | BNC, 50 Ω or 1 MΩ |
| Reference Clock Input | BNC, 10 MHz |
| Reference Clock Output | BNC, 10 MHz |
| Auxiliary Output | BNC, Trigger out |
Environmental and Compliance
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 °C to +70 °C |
| Operating Humidity | Up to 95% relative humidity (non-condensing) |
| Operating Altitude | Up to 3000 m |
| Safety Certifications | IEC 61010-1, EN 61010-1, CAN/CSA-C22.2 No. 61010-1, UL 61010-1 |
| Electromagnetic Compatibility (EMC) | IEC/EN 61326-1 Class A |
Physical Characteristics
| Parameter | Value |
|---|---|
| Form Factor | Benchtop |
| Cooling Fan Noise Level | Forced air cooling, low-noise temperature-controlled fan |
Computer System
| Parameter | Value |
|---|---|
| Operating System | Windows 10 IoT Enterprise 64-bit |
| Processor | Intel Core i7 |
| System Memory (RAM) | 16 GB |
| Storage | ≥ 256 GB removable SSD |
Digital Channels
| Parameter | Value |
|---|---|
| MSO Channels | 16 digital channels (with RTO6-B1 option) |
| MSO Sample Rate | 5 GSa/s |
| MSO Memory Depth | 200 Mpoints per channel |
| MSO Input Impedance | 100 kΩ || 4 pF |
Arbitrary Waveform Generator
| Parameter | Value |
|---|---|
| AWG Channels | 2 analog, 8 pattern generator channels (with RTO6-B6 option) |
| AWG Vertical Resolution | 14-bit |
| AWG Maximum Sample Rate | 500 MS/s |
| AWG Bandwidth | 100 MHz |
Digital Voltmeter (DVM)
| Parameter | Value |
|---|---|
| DVM Channels | 4 (one per analog channel) |
| DVM Resolution | Up to 3 digits |
| DVM Measurements | DC, AC+DC RMS, AC RMS |
Frequency Counter
| Parameter | Value |
|---|---|
| Counter Channels | 2 |
| Counter Resolution | 8 digits |
Power Specifications
| Parameter | Value |
|---|---|
| Power Consumption | Max. 450 W (typical 160 W) |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Probe Interface | Rohde & Schwarz active probe interface |
| Calibration Signal Output | Square wave, 1 kHz, 1 V (Vpp) |
Technology
Digital Oscilloscope
Applications
High-speed digital design, power electronics, RF debug, and serial protocol analysis
Looking for the Rohde & Schwarz RTO64 (1802.0001.04)?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us