The Rohde & Schwarz URE3 is a high-performance broadband RMS and peak voltmeter designed for high-precision AC and DC measurements up to 30 MHz. Featuring a patented rectifier circuit with microprocessor-controlled autocalibration, the URE3 delivers exceptional measurement accuracy across a wide dynamic range. With features like automatic frequency response correction, selectable high-pass and low-pass filters, and an optional comprehensive digital/analog I/O expansion, the URE3 is optimized for demanding lab and automated test system (ATE) applications.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488) standard; optional: ready output, trigger input, TTL frequency counter input, dual-channel analog output (via In/Out option)
Display4.5-digit LCD with selectable scale analog bar graph
Setup Memory9 complete instrument configurations

Physical

ParameterValue
Power Supply100 V / 120 V / 220 V / 240 V (±10%), 47 Hz to 440 Hz
Operating Temperature0 to 50
Dimensions (W×H×D)219 × 103 × 350
Weight4.6

Voltage Measurement Specifications

ParameterValue
AC Voltage Measurement Range50 µV to 300 V
DC Voltage Measurement Range0 to 300 V
Frequency RangeDC, 10 Hz to 30 MHz
Frequency Measurement RangeUp to 30 MHz
Crest Factor RangeUp to 7 (at full scale)
Measurement Resolution4.5 digits
True RMS Converter TypePatented rectifier circuit with microprocessor-controlled autocalibration
AC+DC Coupling CapabilityYes (True RMS AC+DC weighting)
Automatic Frequency Response CorrectionSupported (utilizes measured frequency internally to enhance accuracy at high frequencies)
Zero FunctionSupported (compensates for inherent noise and external noise voltages)

Input Characteristics

ParameterValue
Input Impedance1 MΩ
Input Coupling ModesAC, DC, AC+DC

Measurement Speed and Dynamics

ParameterValue
Maximum Reading Rate30 measurements/s

Signal Conditioning and Filters

ParameterValue
Low-Pass FilterSupported

Display and Math Functions

ParameterValue
Relative Measurement ModeSupported
Peak-Value Measurement ModesPositive peak, negative peak, peak-to-peak
Statistical FunctionsMinima / Maxima logging
Probe Division Factor CorrectionSupported (allows scaling display results for external passive/active probes)

Inputs and Outputs (I/O)

ParameterValue
Dual-Channel Analog OutputSupported (option-dependent via In/Out interface option)
Ready OutputSupported (option-dependent via In/Out interface option)
External Trigger InputSupported (option-dependent via In/Out interface option)
TTL Frequency Counter InputSupported (option-dependent via In/Out interface option)

Input

ParameterValue
Maximum Input Voltage300 V (RMS), 425 V (peak)
Input Capacitance20 pF

Performance

ParameterValue
Basic DC Accuracy±(0.02% of reading + 0.01% of full scale)
Basic AC Accuracy±(0.05% of reading + 0.02% of range) at 1 kHz

Options

ParameterValue
Rear Panel Connector OptionOption URE3-B1 (relocates front-panel inputs and outputs to the rear)

Environmental

ParameterValue
Storage Temperature Range-40 °C to +70 °C

Power Details

ParameterValue
Power ConsumptionApprox. 30 VA
Line Frequency Range47 Hz to 440 Hz

Display & Controls

ParameterValue
Display Resolution320 × 240 pixels

Technology

Patented rectifier with microprocessor-controlled autocalibration

Applications

Broadband voltage measurement, peak detection, and frequency measurement in RF, analog audio, and power electronics calibration.