The Tektronix 2445B is a 150 MHz, 4-channel analog oscilloscope from the renowned Tektronix 2400 Series, known for its high-performance triggering, automated on-screen readouts, and cursor measurements.

Specifications

General

ParameterValue
InterfacesGPIB (Option 10)
Display8 x 10 cm CRT with internal graticule and on-screen readouts

Physical

ParameterValue
Power Supply90 - 250 V AC, 48 - 440 Hz, 120 W maximum
Operating Temperature-15°C to +55°C
Dimensions (W×H×D)329 mm x 137 mm x 439 mm (cabinet only)
Weight9.3 kg

Vertical System

ParameterValue
Number of Channels4
Bandwidth (-3 dB)150 MHz
Rise Time2.33 ns
Deflection Factor Range (CH 1, CH 2)2 mV/div to 5 V/div (in 1-2-5 sequence)
Deflection Factor Range (CH 3, CH 4)0.1 V/div and 0.5 V/div
Deflection Factor Accuracy±2%
Variable Sensitivity Range (CH 1, CH 2)Continuously variable between steps, extends deflection factor to at least 12.5 V/div
Vertical Input Coupling (CH 1, CH 2)AC, DC, GND
Vertical Input Coupling (CH 3, CH 4)DC only
Input Impedance (Resistance)1 MΩ (±0.5%) or 50 Ω (±1%)
Input Impedance (Capacitance)15 pF (±2 pF) (in parallel with 1 MΩ)
Maximum Safe Input Voltage (1 MΩ)400 V (DC + peak AC)
Maximum Safe Input Voltage (50 Ω)5 V RMS
Common Mode Rejection Ratio (CMRR)At least 20:1 at 50 MHz
Vertical Operating ModesCH 1, CH 2, CH 3, CH 4, ADD, ALT, CHOP, INVERT (CH 2)
Vertical Chop FrequencyApproximately 1 MHz
Channel 1 to Channel 2 Delay Match≤ 100 ps
Signal Delay≥ 20 ns of visible pre-trigger trace
Channel 2 Invert CapabilitySelectable on Channel 2
Bandwidth Limit Filter20 MHz
Vertical Dynamic Range (CH 1, CH 2)±8 divisions from graticule center

Horizontal System

ParameterValue
Time Base A Sweep Speed Range500 ms/div to 10 ns/div (in 1-2-5 sequence)
Time Base B Sweep Speed Range50 ms/div to 10 ns/div
Sweep Speed Accuracy±0.7% (+15°C to +35°C, A sweep)
Horizontal Magnifierx10 (extends fastest sweep speed to 1 ns/div)
Horizontal Operating ModesA, A INTEN, ALT, B (Delayed)
X-Y Operation BandwidthDC to 3 MHz
X-Y Phase Difference1° or less from DC to 1 MHz

Triggering System

ParameterValue
Trigger SourcesCH 1, CH 2, CH 3, CH 4, LINE
Trigger Coupling ModesAC, LF REJ, HF REJ, DC, NOISE REJ
Trigger ModesAUTO LEVEL, AUTO, NORM, SINGLE SEQ
Internal Trigger Sensitivity0.3 div from DC to 10 MHz, 1.0 div at 150 MHz

Display and CRT Specifications

ParameterValue
CRT TypeRectangular, internal graticule, meshless scan expansion
Display Area (Graticule Size)8 x 10 cm
Accelerating Voltage16 kV
Phosphor TypeP31 standard
Trace Rotation AdjustmentFront-panel screwdriver-adjustable
Z-Axis Modulation Input Impedance9 kΩ

On-Screen Readouts and Cursor Measurements

ParameterValue
Cursor FunctionsVolts (ΔV), Time (Δt), 1/Time (1/Δt), Phase, Ratio

Signal Outputs and Calibration

ParameterValue
Probe Calibrator Output Voltage0.4 V (±1%) into 1 MΩ
Probe Calibrator Output Frequency1 kHz (±20%)
Channel 1 Vertical Signal Output20 mV/div (±10%) into 50 Ω

Physical Characteristics

ParameterValue
Cooling SystemForced-air cooling (internal fan)

Environmental and Safety

ParameterValue
Storage Temperature Range-62°C to +85°C
Operating Humidity RangeUp to 95% RH at 40°C
Operating Altitude RangeUp to 4,500 m (15,000 ft)

Power Requirements

ParameterValue
AC Line Voltage Range90 V to 250 V AC (continuous range)
AC Line Frequency Range48 Hz to 440 Hz
Maximum Power Consumption120 W (typically 85 W without options)

Environmental

ParameterValue
Environmental Shock50 g, half-sine, 11 ms duration

Option 10 (GPIB Interface)

ParameterValue
GPIB Interface Option (Option 10) CodesSH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT0, C0, E1

Option 01 (DMM)

ParameterValue
Digital Multimeter DC Voltage Accuracy±(0.15% of reading + 1 count) (Option 01)
Digital Multimeter AC Voltage Accuracy±(0.6% of reading + 10 counts) from 40 Hz to 20 kHz (Option 01)

Option 09 / 15 (CTT / Word Recognizer)

ParameterValue
Word Recognizer Input Channels17 bits (Option 09 / Option 15)

Option 06 / 09 (Counter/Timer/Trigger)

ParameterValue
Counter/Timer Timebase Standard Accuracy10 ppm (Option 06 / Option 09)
Counter/Timer High-Stability Timebase Accuracy0.1 ppm (with Option 1E or 1T)

General & Interface

ParameterValue
Setup Memory Capacity30 front-panel setups

Auxiliary Inputs & Outputs

ParameterValue
Maximum Z-Axis Input Voltage30 V (DC + peak AC) / 30 V p-p at 100 kHz

Display System

ParameterValue
Beam FinderCompels display to within the graticule area regardless of position control settings
Graticule IlluminationContinuously variable

Options

ParameterValue
Option 11 Probe Power Outputs±5 V and ±15 V (up to 150 mA per output, supports 2 active probes)
Option 05 TV Trigger FormatsNTSC, PAL, SECAM

Technology

Analog

Applications

Electronic testing, waveform analysis, and troubleshooting