The Tektronix 2465 is a classic 300 MHz, four-channel analog oscilloscope known for its reliability, crisp CRT display, and comprehensive on-screen readout and cursor measurement system. Highly regarded in both engineering and service environments, it offers flexible triggering and precision sweep controls standard for the 2400 Series.

Specifications

General

ParameterValue
InterfacesOptional GPIB (IEEE-488) via Option 10
Display8 x 10 cm CRT with internal graticule and digital readouts
Cooling SystemForced-air circulation via internal fan
Warm-up Time20 minutes

Physical

ParameterValue
Power Supply90 - 250 V AC, 48 - 440 Hz, 120 W maximum
Operating Temperature-15 °C to +55 °C
Dimensions (W×H×D)329 mm × 136 mm × 440 mm

Vertical Deflection System

ParameterValue
Number of Channels4
Bandwidth (-3 dB)300 MHz
Risetime1.17 ns
Deflection Factor Range (CH1, CH2)2 mV/div to 5 V/div in 1-2-5 sequence
Deflection Factor Range (CH3, CH4)0.1 V/div and 0.5 V/div
Deflection Factor Accuracy±2% (+15 °C to +35 °C)
Input Impedance (CH3, CH4)1 MΩ ±1% in parallel with 15 pF ±2 pF
Maximum Input Voltage (1 MΩ)400 V (DC + peak AC)
Maximum Input Voltage (50 Ω)5 V RMS
Channel Isolation (Crosstalk)100:1 at 100 MHz, 50:1 at 300 MHz
Vertical Operating ModesCH 1, CH 2, ADD, ALT, CHOP, CH 3, CH 4
Chop Frequency1 MHz
Invert Channel CapabilityCH 2 only
Delay Line (Signal Delay)Visible signal delay allows viewing of the triggering edge

Horizontal Deflection System (Time Base)

ParameterValue
Time Base ModesA, A INTEN, ALT, B DLY'D
A Sweep Time Range500 ms/div to 5 ns/div (with x10 magnification to 500 ps/div)
B Sweep Time Range50 ms/div to 5 ns/div (with x10 magnification to 500 ps/div)
Sweep Time Accuracy±1% (A sweep, unmagnified, +15 °C to +35 °C)
Sweep Magnificationx10
Magnified Sweep Accuracy±2% (A sweep, +15 °C to +35 °C)
Holdoff Control RangeVariable, increases sweep holdoff by at least a factor of 10

Triggering System

ParameterValue
Trigger SourcesCH 1, CH 2, CH 3, CH 4, Line, Vertical Mode
Trigger ModesAUTO LEVEL, AUTO, NORMAL, SINGLE SEQUENCE
Trigger CouplingDC, AC, NOISE REJ, HF REJ, LF REJ
Trigger Sensitivity (Internal, DC Coupled)0.3 div from DC to 50 MHz, 1.0 div at 300 MHz
External Trigger Input Impedance1 MΩ ±1% in parallel with 15 pF (via CH 3 and CH 4 inputs)
External Trigger Maximum Input Voltage400 V (DC + peak AC)

X-Y Operation

ParameterValue
X-Y Mode Deflection FactorSame as vertical deflection system (CH 1 for X-axis, CH 2 for Y-axis)
X-Axis BandwidthDC to at least 3 MHz

CRT Display & Z-Axis Modulation

ParameterValue
CRT TypeRectangular, internal graticule, meshless scan expansion
Display Area (Graticule Size)8 x 10 cm
Accelerating Potential16 kV
Phosphor TypeGH (P31) standard
Trace Rotation ControlFront-panel screwdriver adjustment
Z-Axis Input SensitivityNoticeable modulation at +1.8 V, positive voltage decreases intensity, +5 V blanks a trace of usable intensity
Z-Axis Input BandwidthDC to 20 MHz
Z-Axis Maximum Input Voltage30 V (DC + peak AC)

On-Screen Readouts & Measurement Cursors

ParameterValue
Cursor Measurement TypesΔV, Δt, 1/Δt (frequency), phase, ratio
Digital Readout Parameter DisplayVolts, time, frequency, phase, scale factors, channel selection, trigger parameters
Auto-Setup FunctionalityThe original 2465 does not feature an Auto-Setup function

Signal Outputs & Calibrators

ParameterValue
Calibrator Output Voltage (Amplitude)0.4 V ±1.0% into 1 MΩ
Calibrator Output Frequency1 kHz nominal
Calibrator Waveform ShapeSquare wave
Channel 1 Vertical Output VoltageChannel 2 Vertical Output Voltage = Approximately 20 mV/div into 50 Ω (rear panel)

Environmental & Safety Compliance

ParameterValue
Storage Temperature Range-55 °C to +75 °C
Operating Humidity RangeUp to 95% RH at +30 °C to +40 °C, non-condensing
Operating Altitude LimitUp to 15,000 feet (4,500 m)
Safety Standards and CertificationsConforms to UL 1244, CSA C22.2 No. 231

Vertical System

ParameterValue
Input Coupling Modes (CH1, CH2)AC, DC, GND, and 50 Ω DC
Input Coupling Modes (CH3, CH4)DC only
Common Mode Rejection Ratio (CMRR)At least 20:1 at 50 MHz (with CH2 inverted)
Bandwidth Limit20 MHz (±4 MHz)
CH 1 to CH 2 Delay Match≤ 100 ps

Horizontal System

ParameterValue
Delay Jitter1 part or less in 20,000 (0.005%) of the maximum available delay
Sweep Separation RangeAt least ±4 divisions

Display

ParameterValue
CRT Graticule MarkingsInternal 8 × 10 cm graticule with 0%, 10%, 90%, and 100% risetime reference lines

Z-Axis Modulation

ParameterValue
Z-Axis Input Resistance9.1 kΩ ± 10%

Power Requirements

ParameterValue
Line Voltage Range90 V to 250 V AC (automatically selected)
Line Frequency Range48 Hz to 440 Hz
Maximum Power Consumption150 W (with options)

Environmental

ParameterValue
Environmental ShockMIL-T-28800C, Type III, Class 5 (50 g, half-sine, 11 ms)
Environmental VibrationMIL-T-28800C, Type III, Class 5 (5 Hz to 55 Hz, 0.015 inch p-p)

Technology

Analog Oscilloscope

Applications

Electronic Design, Signal Analysis, Troubleshooting, Education

Looking for the Tektronix 2465?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us