The Tektronix 2465A is a professional 350 MHz, 4-channel analog oscilloscope from the classic 2400 Series. Renowned for its crisp CRT display, sophisticated cursor measurements, on-screen readout, and high reliability, it serves as a staple in vintage and modern electronic testing environments.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB (via Option 10) |
| Display | CRT, 8×10 cm graticule, with on-screen readout and cursors |
| Warm-up Time | 20 minutes |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 90 V to 250 V AC, 48 Hz to 440 Hz, 120 W maximum |
| Operating Temperature | -15 °C to +55 °C |
| Dimensions (W×H×D) | 329 mm × 160 mm × 439 mm |
| Weight | 9.3 kg |
Vertical System
| Parameter | Value |
|---|---|
| Number of Channels | 4 |
| Analog Bandwidth (-3 dB) (CH 1, CH 2) | 350 MHz |
| Analog Bandwidth (-3 dB) (CH 3, CH 4) | 350 MHz |
| Calculated Rise Time (CH 1, CH 2) | 1 ns |
| Deflection Factor Range (CH 1, CH 2) | 2 mV/div to 5 V/div |
| Deflection Factor Settings (CH 3, CH 4) | 0.1 V/div and 0.5 V/div |
| Input Impedance (CH 1, CH 2) | 1 MΩ || 15 pF or 50 Ω (selectable) |
| Input Impedance (CH 3, CH 4) | 1 MΩ || 15 pF |
| Input Coupling (CH 1, CH 2) | AC, DC, GND |
| Input Coupling (CH 3, CH 4) | DC only |
| Maximum Input Voltage (1 MΩ) | 400 V (DC + peak AC) |
| Maximum Input Voltage (50 Ω) | 5 V RMS |
| Invert Channel Capability | CH 2 |
| Bandwidth Limit | 20 MHz |
| Input Capacitance (CH 1, CH 2) | 15 pF ± 2 pF |
Horizontal System
| Parameter | Value |
|---|---|
| A Time Base Sweep Range | 500 ms/div to 5 ns/div |
| B Time Base Sweep Range | 50 ms/div to 5 ns/div |
| Horizontal Magnification | x10 |
| Magnified Sweep Range | Up to 500 ps/div |
| Horizontal Operating Modes | A, A INTEN, ALT, B (Delayed) |
| A Sweep Holdoff Range | Continuously variable from normal to at least 10:1 |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Coupling Modes | DC, AC, Noise Reject, HF Reject, LF Reject |
| Trigger Level Range (CH 1, CH 2) | ±18 times the Volts/div setting |
X-Y Operation
| Parameter | Value |
|---|---|
| X-Axis Input Source | CH 1 |
| Y-Axis Input Source | CH 2 |
| X-Axis Bandwidth | DC to 3 MHz |
| X-Y Phase Difference | ≤1° (from DC to 1 MHz) |
Display & CRT
| Parameter | Value |
|---|---|
| Active Graticule Area | 8 x 10 divisions (1 div = 1 cm) |
| Phosphor Type | P31 |
| Accelerating Voltage | 16 kV |
| Scale Illumination | Continuously variable |
Interfaces & Auxiliary Signals
| Parameter | Value |
|---|---|
| Calibrator Output Voltage | 400 mV into 1 MΩ (40 mV into 50 Ω) |
| Channel 1 Vertical Signal Output | None (Channel 2 has the Vertical Signal Output) |
Power Specifications
| Parameter | Value |
|---|---|
| Line Frequency Range | 48 Hz to 440 Hz |
Environmental & Reliability
| Parameter | Value |
|---|---|
| Operating Altitude Limit | Up to 15,000 feet (4,570 meters) |
| Non-Operating Altitude Limit | Up to 50,000 feet (15,240 meters) |
| Vibration Resistance | Meets MIL-T-28800C, Class 3 |
| Shock Resistance | Meets MIL-T-28800C, Class 3 (50 g, 11 ms) |
Options & Configurations
| Parameter | Value |
|---|---|
| Option 01 | Digital Multimeter (DMM) |
| Option 05 | TV Waveform Measurement |
| Option 06 | Counter/Timer/Trigger (CTT) |
| Option 10 | IEEE-488 GPIB Interface |
| Option 11 | Probe Power Outputs |
Calibrator
| Parameter | Value |
|---|---|
| Calibrator Current Loop Output | None (no current loop output on this model) |
Options
| Parameter | Value |
|---|---|
| Option 1R | Rackmount configuration |
Environmental
| Parameter | Value |
|---|---|
| Environmental Design Compliance | Designed to meet MIL-T-28800C, Type III, Class 3, Style C |
Triggering
| Parameter | Value |
|---|---|
| A & B Trigger Sensitivity (DC Coupled, CH 1/CH 2) | 0.35 div from DC to 50 MHz, increasing to 1.0 div at 350 MHz |
Setup & Memory
| Parameter | Value |
|---|---|
| Save/Recall Setup Capacity | 30 non-volatile front-panel setups |
| Auto Setup Function | Standard front-panel automatic setup feature |
Technology
Analog
Applications
Electronic testing, debugging, and measurement