The Tektronix 2467B is a legendary 4-channel, 400 MHz analog oscilloscope from the 2400 Series. Famous for its Microchannel Plate (MCP) CRT display, it offers an extremely high visual writing speed of up to 4 div/ns, allowing engineers to easily observe rare, fast-transient anomalies and high-frequency jitter that are invisible on standard CRT oscilloscopes.

Specifications

General

ParameterValue
InterfacesGPIB (optional, via Option 10)
DisplayMicrochannel Plate (MCP) CRT with on-screen readout, 8 × 10 divisions
Warm-up Time20 minutes

Physical

ParameterValue
Power Supply90 V to 250 V AC, 48 Hz to 440 Hz, 120 W typical
Operating Temperature-15 °C to +55 °C

Vertical System

ParameterValue
Number of Channels4
Bandwidth (-3 dB)400 MHz
Rise Time875 ps
Min. Vertical Sensitivity2 mV/div
Maximum Vertical Sensitivity5 V/div
Vertical Accuracy±2%
Input CouplingAC, DC, GND
Input Impedance1 MΩ (±0.5% in parallel with 15 pF) or 50 Ω (±1%)
Channel 1 & 2 Isolation100:1 at 100 MHz, 50:1 at 400 MHz
Maximum Input Voltage (1 MΩ)400 V (DC + peak AC)
Maximum Input Voltage (50 Ω)5 V RMS
Vertical Display ModesCH 1, CH 2, ADD, ALT, CHOP, CH 2 INVERT
Vertical Delay LineYes (permits viewing leading edge of trigger event)
Channel 1 & 2 Input Capacitance15 pF ± 2 pF
Channel 3 & 4 Bandwidth (-3 dB)400 MHz
Channel 3 & 4 Deflection Factors100 mV/div and 500 mV/div

Horizontal System

ParameterValue
Sweep ModesAuto, Normal, Single Sequence
A Sweep Rate Range500 ms/div to 5 ns/div (500 ps/div with x10 magnification)
B Sweep Rate Range50 ms/div to 5 ns/div (500 ps/div with x10 magnification)
Sweep Magnificationx10
X-Y Mode BandwidthDC to 3 MHz
X-Y Phase DifferenceWithin 1° from DC to 1 MHz

Trigger System

ParameterValue
Trigger ModesAuto Level, Auto, Normal, Single Sequence
Trigger CouplingDC, AC, Noise Reject, HF Reject, LF Reject
Variable Trigger HoldoffYes

Display and CRT

ParameterValue
CRT TypeMicrochannel Plate (MCP) CRT
Graticule IlluminationVariable
Trace RotationFront panel adjustable
Beam FinderYes

Signal Inputs & Outputs

ParameterValue
A Gate OutputYes (positive TTL level)
B Gate OutputYes (positive TTL level)
Z-Axis Input (Intensity Modulation)Yes, DC-coupled, positive voltage decreases intensity

Environmental & Safety

ParameterValue
Operating AltitudeUp to 15,000 feet (4,570 m)
Cooling MethodForced air (fan)

Factory Options & Accessories

ParameterValue
Digital Multimeter OptionOption 01 (DMM)
TV Waveform Trigger OptionOption 05
Counter/Timer/Trigger OptionOption 06 (CTT)
CTT with Word Recognizer OptionOption 09
GPIB Interface OptionOption 10
Standard Probes IncludedTwo P6137 10X 400 MHz Passive Probes

Power Requirements

ParameterValue
AC Line Frequency Range48 Hz to 440 Hz

Memory & Storage

ParameterValue
Save/Recall Setups Capacity30 non-volatile setups

Technology

Analog

Applications

Test and Measurement