The Tektronix DPO2024 is a 200 MHz, 4-channel digital phosphor oscilloscope from the DPO2000 Series, designed to deliver efficient troubleshooting and analysis. Featuring a 1 Mpoint record length on all channels, a 1 GS/s sample rate, and Wave Inspector® navigation controls, it provides robust performance for visualizing and searching signal details. The inclusion of the FilterVu™ variable low-pass filter, a bright 7-inch widescreen display, and optional serial triggering and decode options make the DPO2024 a versatile tool for embedded design and serial debug applications.

Specifications

General

ParameterValue
InterfacesUSB 2.0 Host (front panel), USB 2.0 Device (rear panel), LAN (optional via DPO2CONN module), VGA (optional via DPO2CONN module), GPIB (optional via TEK-USB-488)
Display7 in. (180 mm) widescreen TFT-LCD, 480 × 234 pixels
Real-Time ClockYes, user-settable

Physical

ParameterValue
Power Supply100 to 240 V ±10% (50/60 Hz), 115 V ±10% (400 Hz); 80 W maximum
Operating Temperature0 to +50 °C
Dimensions (W×H×D)377 mm × 180 mm × 134 mm
Weight3.6 kg
Kensington Security SlotRear-panel security slot connects to standard Kensington-style lock
Cooling Clearance50 mm (2 in.) on the left side and rear of the instrument

Vertical System - Analog Channels

ParameterValue
Number of Channels4
Analog Bandwidth (-3 dB)200 MHz
Calculated Rise Time2.1 ns
Input CouplingAC, DC, GND
Input Impedance1 MΩ ± 2% in parallel with 11.5 pF ± 2 pF
Input Sensitivity Range2 mV/div to 5 V/div
Vertical Resolution8 bits
Maximum Input Voltage300 Vrms CAT II with peaks ≤ ±450 V
DC Gain Accuracy±3% for 10 mV/div to 5 V/div, ±4% for 2 mV/div to 5 mV/div
Offset Range2 mV/div to 200 mV/div: ±1 V; >200 mV/div to 5 V/div: ±25 V
Channel-to-Channel Isolation≥ 100:1 at ≤ 100 MHz, ≥ 30:1 at > 100 MHz to 200 MHz
Probe InterfaceTekVPI® Probe Interface

Horizontal System - Analog Channels

ParameterValue
Timebase Range2.0 ns to 100 s per division
Timebase Delay Time Range-10 divisions to 5000 s
Channel-to-Channel Deskew Range±100 ns
Timebase Accuracy±25 ppm
Maximum Duration at Highest Sample Rate1 ms

Acquisition System

ParameterValue
Maximum Real-Time Sample Rate1.0 GS/s on all channels
Maximum Record Length1 Mpoint on all channels
Waveform Capture Rate5,000 wfm/s (maximum)
Sample ModeAcquires sample values
Peak Detect ModeCaptures glitches down to 3.6 ns width at all sweep speeds
Averaging ModeAverages 2 to 512 waveforms
Roll ModeScrolls waveforms right to left at sweep speeds slower than or equal to 40 ms/div

Trigger System

ParameterValue
Trigger ModesAuto, Normal, Single
Trigger CouplingAC, DC, HF Reject (attenuates >85 kHz), LF Reject (attenuates <65 kHz), Noise Reject (increases threshold)
Trigger Holdoff Range20 ns to 8 s
Trigger Level Ranges±8 divisions from screen center
Edge TriggeringRising, falling, or either slope on any channel
Pulse Width TriggeringTrigger on width of positive or negative pulses that are >, <, =, or ≠ to a specified period of time (20 ns to 8 s)
Runt TriggeringTrigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again
Logic TriggeringTrigger when any logical pattern of channels goes false or stays true for specified period of time (20 ns to 8 s)
Setup and Hold TriggeringTrigger on violations of both setup time and hold time between clock and data present on any of the input channels
Rise/Fall Time TriggeringTrigger on pulse edge rates that are faster or slower than specified
Video TriggeringTrigger on all lines, specific line numbers, odd, even, or all fields on NTSC, PAL, and SECAM video signals
I2C/SPI Serial Triggering (Optional)Trigger on packet content of I2C and SPI buses (requires DPO2EMBD module)
CAN/LIN Serial Triggering (Optional)Trigger on packet content of CAN and LIN buses (requires DPO2AUTO module)
RS-232/422/485/UART Serial Triggering (Optional)Trigger on packet content of RS-232/422/485/UART buses (requires DPO2COMP module)
Internal Trigger Sensitivity (DC Coupled)0.4 div from DC to 50 MHz, 0.6 div from 50 MHz to 100 MHz, 0.8 div from 100 MHz to 200 MHz

Waveform Measurements and Math

ParameterValue
CursorsWaveform and Screen cursors
Automatic Measurements29 automatic measurements
Measurement StatisticsMean, Min, Max, Standard Deviation
Reference LevelsUser-definable in percent or units (10%, 50%, 90% default)
GatingIsolate measurements using screen, cursors, or full record
Waveform Math OperatorsAddition, subtraction, multiplication, FFT
Fast Fourier Transform (FFT)Spectral magnitude. Windows: Rectangular, Hamming, Hanning, Blackman-Harris

Display Characteristics

ParameterValue
Display TypeTFT-LCD Color Display
Display Resolution480 × 234 pixels (WQVGA)
Display Size7 in. (180 mm) diagonal
Waveform StylesVectors, Dots, Variable Persistence, Infinite Persistence
FormatYT and XY
GraticulesFull, Grid, Crosshair, Frame

Input / Output Ports

ParameterValue
USB 2.0 High-Speed Host Port1x front panel port supporting USB flash drives
USB 2.0 High-Speed Device Port1x rear panel port supporting USBTMC or direct printing to PictBridge compatible printers
LAN Port (Ethernet)Optional (via DPO2CONN connectivity module; RJ-45 10/100Base-T)
Video Out PortOptional (via DPO2CONN connectivity module; DB-15 female connector for external monitors)
GPIB Interface (Optional)Available via TEK-USB-488 adapter
Probe Compensator OutputFront-panel pins; Amplitude ~5 V into ≥ 1 MΩ load, Frequency 1 kHz

Power Source

ParameterValue
Power Source Voltage100 to 240 V ±10%
Power Source Frequency45 to 66 Hz (90 to 264 V), 360 to 440 Hz (100 to 132 V)
Power Consumption80 W maximum

Physical Characteristics

ParameterValue
Dimensions (Height)180 mm (7.1 in.)
Dimensions (Width)377 mm (14.9 in.)
Dimensions (Depth)134 mm (5.3 in.)
Weight (Net)3.6 kg (7.9 lbs.)
Weight (Shipping)6.2 kg (13.7 lbs.)
Rackmount Configuration OptionsRM2000 Rackmount Kit

Environmental and Compliance

ParameterValue
Non-operating Temperature-40 °C to +71 °C (-40 °F to +160 °F)
Operating HumidityHigh temperature: 0% to 60% RH at +40 °C to +50 °C; Low temperature: 0% to 90% RH at 0 °C to +40 °C
Operating Altitude3,000 m (9,843 ft.)
Non-operating Altitude12,000 m (39,370 ft.)
Electromagnetic Compatibility (EMC) Directive2004/108/EC, EN61326-1:2006, EN61326-2-1:2006
Safety CertificationsUL61010-1:2004, CAN/CSA-C22.2 No. 61010.1:2004, EN61010-1:2001, IEC61010-1:2001

Vertical System

ParameterValue
Hardware Bandwidth Limits20 MHz
Input Capacitance11.5 pF ± 2 pF
Vertical Position Range±5 divisions

Search & Navigation

ParameterValue
Wave Inspector NavigationDedicated front-panel controls for Zoom, Pan, Play/Pause, Set/Clear Mark, and Prev/Next Mark

Environmental

ParameterValue
Vibration (Operating)0.31 gRMS, 5 Hz to 500 Hz, 10 min per axis, 3 axes
Vibration (Non-Operating)2.46 gRMS, 5 Hz to 500 Hz, 10 min per axis, 3 axes

Display / Interface

ParameterValue
User Interface LanguagesEnglish, French, German, Italian, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Korean, Japanese, Russian

Software

ParameterValue
Included SoftwareOpenChoice® Desktop, NI LabVIEW SignalExpress™ Tektronix Edition LE
Driver SupportIVI-COM, IVI-C, LabVIEW

Storage

ParameterValue
Waveform Storage FormatsCSV, TXT, PNG, BMP, TIFF, ISF, SET
Internal Waveform Storage2 reference waveforms
Internal Setup Storage10 setups

Performance

ParameterValue
FFT WindowsHanning, Rectangular, Hamming, Blackman-Harris

Triggering

ParameterValue
Trigger SourcesChannel 1, Channel 2, Channel 3, Channel 4, AC Line