The Tektronix DPO3032 is a 300 MHz, 2-channel Digital Phosphor Oscilloscope (DPO) belonging to the DPO3000 Series. Designed for comprehensive visualization and debugging of complex electronic systems, the DPO3032 delivers a 2.5 GS/s real-time sampling rate across all channels, a generous 5 Mpoint record length, and a dedicated Wave Inspector® control system for seamless waveform navigation.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 Host (2 ports), USB 2.0 Device (USBTMC), LAN (10/100 Base-T Ethernet), Video Out (SVGA) |
| Display | 9 inch (228.6 mm) widescreen TFT-LCD, 800 × 480 pixels (WVGA) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 V ±10% (50/60 Hz), 115 V ±10% (400 Hz), 120 W maximum |
| Operating Temperature | 0 °C to +50 °C |
| Dimensions (W×H×D) | 416.6 mm × 203.2 mm × 137.2 mm |
| Weight | 4.17 kg |
| Cooling Clearance | 50 mm (2 in.) required on left side and rear of instrument |
Vertical System
| Parameter | Value |
|---|---|
| Analog Bandwidth (-3 dB) | 300 MHz |
| Number of Input Channels | 2 |
| Calculated Rise Time (10% to 90%) | 1.17 ns |
| Input Impedance | 1 MΩ ±1% (13 pF ±2 pF), 50 Ω ±1% |
| Input Coupling | AC, DC, GND |
| Vertical Resolution (ADC) | 8 bits (11 bits with HiRes) |
| DC Gain Accuracy | ±1.5% for 5 mV/div and above, ±2.0% for 2 mV/div, ±2.5% for 1 mV/div |
| Maximum Input Voltage (1 MΩ) | 300 Vrms CAT II with peaks ≤ ±450 V |
| Maximum Input Voltage (50 Ω) | 5 Vrms with peaks ≤ ±20 V |
| Position Range | ±5 divisions |
| Hardware Bandwidth Limits | 20 MHz |
| Channel-to-Channel Isolation | ≥100:1 at ≤300 MHz |
| Offset Range (1 mV/div to 50 mV/div) | ±1 V |
| Offset Range (50.5 mV/div to 99.5 mV/div) | ±0.5 V |
| Offset Range (100 mV/div to 500 mV/div) | ±10 V |
| Offset Range (1 V/div to 5 V/div) | ±100 V |
| Offset Range (5.05 V/div to 10 V/div) | ±50 V |
| Probe Interface | TekVPI |
| Vertical Sensitivity Range (1 M̤) | 1 mV/div to 10 V/div |
| Vertical Sensitivity Range (50 ̤) | 1 mV/div to 1 V/div |
Horizontal System
| Parameter | Value |
|---|---|
| Maximum Real-Time Sampling Rate | 2.5 GS/s (on all channels) |
| Maximum Record Length | 5 Mpoints (on all channels) |
| Time Base Range | 1 ns/div to 1000 s/div |
| Time Base Delay Time Range | -10 divisions to 5000 s |
| Channel-to-Channel Deskew Range | ±100 ns |
| Time Base Accuracy | ±10 ppm |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Sources | CH1, CH2, Line, External |
| Trigger Modes | Auto, Normal, Single |
| Trigger Coupling | DC, AC, HF Reject (> 50 kHz), LF Reject (< 50 kHz), Noise Reject |
| Trigger Holdoff Range | 20 ns to 8 s |
| Edge Triggering | Standard |
| Pulse Width Triggering | Yes (4 ns to 8 s) |
| Runt Triggering | Yes (minimum pulse width 4 ns) |
| Window Triggering | No |
| Timeout Triggering | Yes (4 ns to 8 s) |
| Pattern/State Triggering | Yes |
| Setup/Hold Triggering | Yes |
| External Trigger Input Impedance | 1 MΩ ±1% (13 pF ±2 pF) |
| External Trigger Maximum Input Voltage | 300 Vrms CAT II with peaks ≤ ±450 V |
| Video Trigger Formats | NTSC, PAL, SECAM, and HDTV (480i, 576i, 480p, 576p, 720p, 1080i, 1080p) |
Acquisition System
| Parameter | Value |
|---|---|
| Acquisition Modes | Sample, Peak Detect, Averaging, Envelope, HiRes, Roll |
| Peak Detect Mode Min Pulse Width | 400 ps |
| Averaging Factor Range | 2 to 512 |
| Maximum Waveform Capture Rate | 50,000 wfm/s |
Waveform Measurements and Analysis
| Parameter | Value |
|---|---|
| Automatic Measurements | 29 |
| Waveform Histograms | No |
| Basic Math Functions | Add, Subtract, Multiply, FFT |
| FFT Window Types | Rectangular, Hamming, Hanning, Blackman-Harris |
| Limit and Mask Testing | Optional (with DPO3LMT) |
Display and User Interface
| Parameter | Value |
|---|---|
| Color Grading / Intensity Modulation | Yes |
Connectivity and Ports
| Parameter | Value |
|---|---|
| Auxiliary Output (Trigger Out) | BNC connector |
| Probe Calibration Output | 1 kHz, 0 to 2.5 V |
Environmental Specifications
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 °C to +71 °C |
| Operating Altitude | Up to 3,000 m (10,000 ft) |
| Non-Operating Altitude | Up to 12,192 m (40,000 ft) |
Physical Characteristics
| Parameter | Value |
|---|---|
| Form Factor | Benchtop |
Wave Inspector
| Parameter | Value |
|---|---|
| Wave Inspector Controls | Dedicated front-panel controls for panning, zooming, playing, pausing, setting/clearing marks, and searching |
Optional Analysis
| Parameter | Value |
|---|---|
| Serial Bus Decode and Trigger Options | I²C, SPI, CAN, LIN, RS-232/422/485/UART, I²S/LJ/RJ/TDM (with optional application modules) |
| Power Analysis Option | DPO3PWR module provides automated power measurements and analysis |
Software & Connectivity
| Parameter | Value |
|---|---|
| Software Support | OpenChoice® Desktop, National Instruments LabVIEW SignalExpress Tektronix Edition |
Compliance & Safety
| Parameter | Value |
|---|---|
| Safety Certifications | UL61010-1:2004, CAN/CSA-C22.2 No. 61010.1:2004, EN61010-1:2001, IEC61010-1:2001 |
| Electromagnetic Compatibility | EC Council Directive 2004/108/EC, EN61326-1:2006 |
Triggering
| Parameter | Value |
|---|---|
| Internal Trigger Sensitivity | 0.4 div from DC to 50 MHz, increasing to 1.0 div at 300 MHz |
| External Trigger Sensitivity | 200 mV from DC to 50 MHz, increasing to 500 mV at 300 MHz |
| Trigger Level Range | ±8 div from screen center (internal), ±8 V (external) |
Inputs & Outputs
| Parameter | Value |
|---|---|
| USB Host Ports | 2x USB 2.0 (1 front, 1 rear) |
| USB Device Port | 1x USB 2.0 (rear, supports PictBridge and PC communication) |
| LAN Port | 1x RJ-45, 10/100Base-T Ethernet |
| Video Output Port | 1x DB-15 VGA connector |
| GPIB Interface | Optional via TEK-USB-488 adapter |
Serial Bus & Options
| Parameter | Value |
|---|---|
| Optional Application Modules | DPO3AERO (MIL-STD-1553), DPO3AUDIO (I2S/LJ/RJ/TDM), DPO3AUTO (CAN/LIN), DPO3COMP (RS-232/422/485/UART), DPO3EMBD (I2C/SPI), DPO3FLEX (FlexRay), DPO3PWR (Power Analysis) |
Technology
Digital Phosphor Oscilloscope (DPO)
Applications
Electronic design, debug, serial bus troubleshooting, and power measurement