The Tektronix DPO7054 is a 4-channel, 500 MHz Digital Phosphor Oscilloscope from the DPO7000 series. Featuring real-time sampling rates up to 10 GS/s, a FastAcq waveform capture rate exceeding 250,000 wfms/s, and standard Pinpoint™ triggering, the DPO7054 is optimized for signal integrity analysis, digital design verification, and troubleshooting.
Specifications
General
| Parameter | Value |
|---|---|
| Display | 12.1-inch color TFT-LCD touchscreen, 1024 × 768 XGA resolution |
Vertical System
| Parameter | Value |
|---|---|
| Input Channels | 4 |
| Analog Bandwidth (-3 dB) | 500 MHz |
| Calculated Rise Time (10% to 90%) | 700 ps |
| Calculated Rise Time (20% to 80%) | 500 ps |
| Hardware Bandwidth Limits | 250 MHz or 20 MHz |
| Vertical Resolution | 8 bits (>11 bits in Hi-Res mode) |
| Input Coupling | DC, AC, GND |
| Input Sensitivity Range (1 MΩ) | 1 mV/div to 10 V/div |
| Input Sensitivity Range (50 Ω) | 1 mV/div to 1 V/div |
| Maximum Input Voltage (50 Ω) | 5 V rms with peaks ≤ ±24 V |
| DC Gain Accuracy | ±1% |
Horizontal System
| Parameter | Value |
|---|---|
| Maximum Real-Time Sample Rate (1 Channel) | 10 GS/s |
| Maximum Real-Time Sample Rate (2 Channels) | 5 GS/s |
| Maximum Real-Time Sample Rate (4 Channels) | 2.5 GS/s |
| Maximum Record Length (Standard) | 10M points per channel (4-ch) |
| Maximum Record Length (Optional Upgrade) | Up to 400M points (1-ch) / 100M points (4-ch) with Option 10RL |
| Time Base Accuracy | ±2.5 ppm |
| Channel-to-Channel Deskew Range | ±75 ns |
Acquisition System
| Parameter | Value |
|---|---|
| Acquisition Modes | Sample, Peak Detect, Averaging, Envelope, Hi-Res, FastAcq, FastFrame |
| Maximum Waveform Capture Rate (FastAcq) | >250,000 wfms/s |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Auto, Normal, Single |
| Trigger System | Pinpoint™ Trigger System |
| Trigger Types | Edge, Glitch, Width, Runt, Window, Timeout, Transition, Setup/Hold, Logic Pattern, Logic State, Video, Serial Pattern |
| Trigger Coupling | DC, AC, HF Reject, LF Reject, Noise Reject |
Display & User Interface
| Parameter | Value |
|---|---|
| Display Size | 12.1 in (307.3 mm) |
| Display Resolution | 1024 × 768 (XGA) |
| Touchscreen Interface | Standard integrated touchscreen |
Connectivity & I/O Interfaces
| Parameter | Value |
|---|---|
| Probe Interface System | TekVPI Probe Interface |
Power Supply
| Parameter | Value |
|---|---|
| Mains Frequency | 47 to 63 Hz (100 to 240 V), 360 to 440 Hz (115 V) |
| Maximum Power Consumption | 550 W |
Environmental & Safety
| Parameter | Value |
|---|---|
| Non-Operating Temperature | -40 °C to +71 °C |
| Operating Altitude | 3,000 m (9,843 ft) |
Environmental
| Parameter | Value |
|---|---|
| Non-Operating Altitude | 12,192 m (40,000 ft) |
Connectivity
| Parameter | Value |
|---|---|
| LAN Port | 1× RJ-45, 10/100/1000Base-T |
| GPIB Interface | IEEE-488.2 standard connector |
Performance
| Parameter | Value |
|---|---|
| Automated Measurements | 53 built-in measurements |
Compliance
| Parameter | Value |
|---|---|
| Safety Certifications | UL61010-1, CSA22.2 No. 61010-1, EN61010-1, IEC61010-1 |
| LXI Compliance | LXI Class C |
Accessories
| Parameter | Value |
|---|---|
| Standard Included Probes | 4× P6139A 500 MHz 10x Passive Probes |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Probe Interface Compatibility | TekVPI Probe Interface (supports auto-scaling, units, and power for active/current probes) |
Waveform Analysis
| Parameter | Value |
|---|---|
| Math Waveforms | 4 math waveforms (Math 1 to Math 4) |
| FFT Window Functions | Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential |
Automated Measurements
| Parameter | Value |
|---|---|
| Measurement Statistics | Mean, Minimum, Maximum, Standard Deviation, Population |
Software & Control
| Parameter | Value |
|---|---|
| Remote Web Interface | e*Scope web-based remote control via standard web browser |
Technology
Digital Phosphor Oscilloscope (DPO)
Applications
Signal Integrity Verification, Debugging, Compliance Testing, Embedded Systems