The Tektronix DPO7054 is a 4-channel, 500 MHz Digital Phosphor Oscilloscope from the DPO7000 series. Featuring real-time sampling rates up to 10 GS/s, a FastAcq waveform capture rate exceeding 250,000 wfms/s, and standard Pinpoint™ triggering, the DPO7054 is optimized for signal integrity analysis, digital design verification, and troubleshooting.

Specifications

General

ParameterValue
Display12.1-inch color TFT-LCD touchscreen, 1024 × 768 XGA resolution

Vertical System

ParameterValue
Input Channels4
Analog Bandwidth (-3 dB)500 MHz
Calculated Rise Time (10% to 90%)700 ps
Calculated Rise Time (20% to 80%)500 ps
Hardware Bandwidth Limits250 MHz or 20 MHz
Vertical Resolution8 bits (>11 bits in Hi-Res mode)
Input CouplingDC, AC, GND
Input Sensitivity Range (1 MΩ)1 mV/div to 10 V/div
Input Sensitivity Range (50 Ω)1 mV/div to 1 V/div
Maximum Input Voltage (50 Ω)5 V rms with peaks ≤ ±24 V
DC Gain Accuracy±1%

Horizontal System

ParameterValue
Maximum Real-Time Sample Rate (1 Channel)10 GS/s
Maximum Real-Time Sample Rate (2 Channels)5 GS/s
Maximum Real-Time Sample Rate (4 Channels)2.5 GS/s
Maximum Record Length (Standard)10M points per channel (4-ch)
Maximum Record Length (Optional Upgrade)Up to 400M points (1-ch) / 100M points (4-ch) with Option 10RL
Time Base Accuracy±2.5 ppm
Channel-to-Channel Deskew Range±75 ns

Acquisition System

ParameterValue
Acquisition ModesSample, Peak Detect, Averaging, Envelope, Hi-Res, FastAcq, FastFrame
Maximum Waveform Capture Rate (FastAcq)>250,000 wfms/s

Trigger System

ParameterValue
Trigger ModesAuto, Normal, Single
Trigger SystemPinpoint™ Trigger System
Trigger TypesEdge, Glitch, Width, Runt, Window, Timeout, Transition, Setup/Hold, Logic Pattern, Logic State, Video, Serial Pattern
Trigger CouplingDC, AC, HF Reject, LF Reject, Noise Reject

Display & User Interface

ParameterValue
Display Size12.1 in (307.3 mm)
Display Resolution1024 × 768 (XGA)
Touchscreen InterfaceStandard integrated touchscreen

Connectivity & I/O Interfaces

ParameterValue
Probe Interface SystemTekVPI Probe Interface

Power Supply

ParameterValue
Mains Frequency47 to 63 Hz (100 to 240 V), 360 to 440 Hz (115 V)
Maximum Power Consumption550 W

Environmental & Safety

ParameterValue
Non-Operating Temperature-40 °C to +71 °C
Operating Altitude3,000 m (9,843 ft)

Environmental

ParameterValue
Non-Operating Altitude12,192 m (40,000 ft)

Connectivity

ParameterValue
LAN Port1× RJ-45, 10/100/1000Base-T
GPIB InterfaceIEEE-488.2 standard connector

Performance

ParameterValue
Automated Measurements53 built-in measurements

Compliance

ParameterValue
Safety CertificationsUL61010-1, CSA22.2 No. 61010-1, EN61010-1, IEC61010-1
LXI ComplianceLXI Class C

Accessories

ParameterValue
Standard Included Probes4× P6139A 500 MHz 10x Passive Probes

Inputs & Outputs

ParameterValue
Probe Interface CompatibilityTekVPI Probe Interface (supports auto-scaling, units, and power for active/current probes)

Waveform Analysis

ParameterValue
Math Waveforms4 math waveforms (Math 1 to Math 4)
FFT Window FunctionsRectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential

Automated Measurements

ParameterValue
Measurement StatisticsMean, Minimum, Maximum, Standard Deviation, Population

Software & Control

ParameterValue
Remote Web Interfacee*Scope web-based remote control via standard web browser

Technology

Digital Phosphor Oscilloscope (DPO)

Applications

Signal Integrity Verification, Debugging, Compliance Testing, Embedded Systems

Looking for the Tektronix DPO7054?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us