The Tektronix MDO4034-3 is a 350 MHz, 4-channel mixed domain oscilloscope from the MDO4000 series. It is the world's first oscilloscope category to feature an integrated 3 GHz RF spectrum analyzer, 16 digital channels, and a 20 Mpoint record length, enabling time-correlated analysis of analog, digital, and RF signals in a single instrument.

Specifications

General

ParameterValue
Interfaces4 x USB 2.0 host ports (2 front, 2 rear), 1 x USB 2.0 device port (rear), 1 x Integrated 10/100/1000BASE-T Ethernet port, 1 x Video out port, 1 x Auxiliary output (Trigger out), 1 x External Reference input
Display10.4 inch (264 mm) liquid-crystal TFT color display, 1024 x 768 pixels (XGA)

Physical

ParameterValue
Operating Temperature0 to +50 °C
Dimensions (W×H×D)439 mm × 229 mm × 147 mm
Weight5 kg (11 lbs)
Rackmount Height5U

Analog Channel Specifications

ParameterValue
Number of Analog Channels4
Analog Bandwidth (-3 dB)350 MHz
Calculated Rise Time1 ns
Input CouplingAC, DC
Input Impedance1 MΩ ±1%, 50 Ω ±1%
Vertical Resolution8 bits (11 bits with Hi Res)
Maximum Input Voltage (1 MΩ)300 Vrms CAT II with peaks ≤ ±425 V
Maximum Input Voltage (50 Ω)5 Vrms with peaks ≤ ±20 V
Hardware Bandwidth Limit20 MHz or 250 MHz

Digital Channel Specifications (MSO)

ParameterValue
Number of Digital Channels16
MagniVu Fine Timing Resolution60.6 ps
Vertical Resolution (Digital)1 bit
Minimum Detectable Pulse Width (Digital)1 ns (typical)

Spectrum Analyzer Specifications (RF Channel)

ParameterValue
RF Input Channels1
RF Frequency Range50 kHz - 3 GHz
RF Real-time Capture Bandwidth≥1 GHz
Maximum RF Input Level (DC safe)±40 V DC
RF to Analog Channel Skew<5 ns
RF Frequency Domain Trace TypesNormal, Average, Max Hold, Min Hold
RF Time Domain Trace TypesAmplitude vs Time, Frequency vs Time, Phase vs Time
RF Automatic MarkersOne to eleven peaks identified based on user-adjustable threshold and excursion values
RF Manual MarkersTwo manual markers indicating frequency, amplitude, noise density, and phase noise

Acquisition and Horizontal System

ParameterValue
Maximum Analog Sample Rate2.5 GS/s
Maximum Digital Sample Rate500 MS/s (2 ns resolution)
Maximum Record Length (Analog)20 M points
Maximum Record Length (Digital)20M points
Time Base Range1 ns to 1000 s
Maximum Duration at Highest Sample Rate8 ms
Time-Base Delay Time Range-10 divisions to 5000 s
Channel-to-Channel Deskew Range±125 ns
Acquisition Mode - SampleAcquire sampled values
Acquisition Mode - Peak DetectCaptures glitches as narrow as 1.6 ns at all sweep speeds
Acquisition Mode - AveragingFrom 2 to 512 waveforms included in average
Acquisition Mode - EnvelopeMin-max envelope reflecting Peak Detect data over multiple acquisitions
Acquisition Mode - Hi ResReal-time boxcar averaging reduces random noise and increases vertical resolution
Acquisition Mode - RollScrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div

Trigger System

ParameterValue
Trigger ModesAuto, Normal, Single
Trigger Holdoff Range20 ns to 8 s
Optional Serial Triggering and AnalysisI2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, I2S/LJ/RJ/TDM
Trigger Level Range (Any Channel)±8 divisions from center of screen

Waveform Measurements and Analysis

ParameterValue
Waveform Measurements and AnalysisCursors, automatic measurements (time & frequency domains), statistics, gating, waveform histogram, histogram measurements, waveform math
Optional Advanced AnalysisPower measurements, limit/mask testing

Display and User Interface

ParameterValue
Display InterpolationSin(x)/x

Connectivity and Interfaces

ParameterValue
Probe Compensator Output Amplitude0 to 2.5 V
Probe Compensator Output Frequency1 kHz
LXI ComplianceLXI Class C, Version V1.3

Physical and Power Characteristics

ParameterValue
Depth147 mm (5.8 in)

Vertical System - Analog Channels

ParameterValue
Vertical Sensitivity Range (1 MΩ)1 mV/div to 10 V/div
Vertical Sensitivity Range (50 Ω)1 mV/div to 1 V/div

RF System

ParameterValue
FFT WindowsKaiser-Bessel, Rectangular, Hamming, Hanning, Blackman-Harris, Flat-Top

Power Specifications

ParameterValue
Power Source Voltage100 to 240 V ±10%
Power Source Frequency50 to 60 Hz (100 to 240 V), 400 Hz ±10% (115 V)
Power Consumption225 W maximum

Search & Navigation

ParameterValue
Wave Inspector ControlsDedicated front-panel controls for zoom, pan, play/pause, set/clear mark, and search

Technology

Mixed Domain Oscilloscope (MDO)

Applications

Mixed-signal design, RF system integration, embedded debugging, and EMI troubleshooting