The Tektronix MDO4054-6 is a mixed domain oscilloscope integrating 4 analog channels (500 MHz bandwidth), 16 digital channels, and a dedicated RF channel (50 kHz to 6 GHz). It enables time-correlated analog, digital, and RF signal acquisitions for comprehensive system-level debugging and analysis.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | 4 x USB 2.0 host (2 front, 2 rear), 1 x USB 2.0 device (rear), 10/100/1000BASE-T Ethernet LAN, Video Out, Auxiliary Out, External Reference In |
| Display | 10.4 in (264 mm) Liquid-crystal TFT color display, XGA (1024 x 768 pixels) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 V ±10% at 50/60 Hz ±10%; 115 V ±10% at 400 Hz ±10%; 250 W maximum |
| Operating Temperature | 0 °C to +50 °C |
| Dimensions (W×H×D) | 439 × 229 × 147 mm |
| Weight | 5 kg |
| Required Cooling Clearance | 51 mm (2.0 in) on left, right, and rear |
Vertical System - Analog Channels
| Parameter | Value |
|---|---|
| Number of Analog Channels | 4 |
| Analog Bandwidth | 500 MHz |
| Rise Time | 700 ps |
| Hardware Bandwidth Limits | 20 MHz or 250 MHz |
| Input Coupling | AC, DC |
| Input Impedance | 1 MΩ ±1%, 50 Ω ±1% |
| Vertical Resolution | 8 bits (11 bits with Hi Res) |
| Maximum Input Voltage | 1 MΩ: 300 Vrms CAT II (peaks ≤±425 V); 50 Ω: 5 Vrms (peaks ≤±20 V) |
Horizontal System - Analog Channels
| Parameter | Value |
|---|---|
| Maximum Duration at Highest Sample Rate | 8 ms |
| Time Base Delay Time Range | -10 divisions to 5000 s |
| Channel-to-Channel Deskew Range | ±125 ns |
Spectrum Analyzer System
| Parameter | Value |
|---|---|
| Number of RF Channels | 1 |
| RF Frequency Range | 50 kHz to 6 GHz |
| Span | 1 kHz - 6 GHz, in a 1-2-5 sequence |
| Resolution Bandwidth (RBW) | 20 Hz - 10 MHz in a 1-2-3-5 sequence |
| Vertical Scale | 1 dB/div to 20 dB/div in a 1-2-5 sequence |
| Vertical Position Range | -10 divs to +10 divs |
| Vertical Units | dBm, dBmV, dBμV, dBμW, dBmA, dBμA |
| Displayed Average Noise Level (DANL) | <-130 dBm/Hz (50 kHz - 5 MHz); <-148 dBm/Hz (5 MHz - 3 GHz); <-140 dBm/Hz (3 GHz - 6 GHz) |
| Residual Response | <-78 dBm |
| RF to Analog Channel Skew | <5 ns |
| Frequency Domain Trace Types | Normal, Average, Max Hold, Min Hold |
| Time Domain Trace Types | Amplitude vs Time, Frequency vs Time, Phase vs Time |
Logic Analyzer System - Digital Channels
| Parameter | Value |
|---|---|
| Number of Digital Channels | 16 |
| Input Dynamic Range | 30 Vp-p ≤200 MHz; 10 Vp-p >200 MHz |
Horizontal System - Digital Channels
| Parameter | Value |
|---|---|
| Maximum Sample Rate (Digital) | 500 MS/s (2 ns resolution) main; MagniVu fine timing resolution 60.6 ps |
| Maximum Record Length (Digital) | 20M points |
| Minimum Detectable Pulse Width | 1 ns (typical) |
| Channel-to-Channel Skew | 500 ps (typical) |
Acquisition System
| Parameter | Value |
|---|---|
| Maximum Sample Rate (Analog) | 2.5 GS/s |
| Maximum Record Length | 20 M |
| Acquisition Modes | Sample, Peak Detect, Averaging, Envelope, Hi Res, Roll |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Auto, Normal, and Single |
| Trigger Holdoff Range | 20 ns to 8 s |
| Standard Trigger Types | Edge, Sequence (B-trigger), Pulse Width, Runt, Logic, Setup and Hold, Rise/Fall Time, Video, Parallel |
Connectivity and Interfaces
| Parameter | Value |
|---|---|
| Probe Compensator Output | 0 to 2.5 V amplitude; 1 kHz frequency |
| LAN eXtensions for Instrumentation (LXI) | LXI Class C, Version V1.3 |
Horizontal System
| Parameter | Value |
|---|---|
| Time Base Accuracy | ±5 ppm over any ≥1 ms interval |
Vertical System
| Parameter | Value |
|---|---|
| Input Sensitivity Range (1 MΩ) | 1 mV/div to 10 V/div |
| Input Sensitivity Range (50 Ω) | 1 mV/div to 1 V/div |
| DC Gain Accuracy | ±1.5% (derated at 0.10%/°C above 30 °C) |
Environmental
| Parameter | Value |
|---|---|
| Operating Humidity | 5% to 90% RH (≤30 °C); 5% to 60% RH (>30 °C to 50 °C) |
| Operating Altitude | Up to 3,000 meters (9,843 feet) |
| Non-operating Altitude | Up to 12,000 meters (39,370 feet) |
Compliance
| Parameter | Value |
|---|---|
| Safety Compliance | UL61010-1:2004, CAN/CSA-C22.2 No. 61010.1:2004, EN61010-1:2001, IEC61010-1:2001 |
Waveform Math
| Parameter | Value |
|---|---|
| Standard Math | Add, Subtract, Multiply, Divide |
| Advanced Math | Integrate, Differentiate, FFT |
Acquisition
| Parameter | Value |
|---|---|
| Maximum Waveform Capture Rate | > 50,000 wfms/s |
Digital Channels
| Parameter | Value |
|---|---|
| Digital Input Impedance | 100 kΩ in parallel with 3 pF |
| Minimum Voltage Swing (Digital) | 400 mV p-p |
| Logic Threshold Selections | TTL, CMOS, ECL, PECL, User-defined |
Triggering
| Parameter | Value |
|---|---|
| Trigger Coupling | DC, AC, HF Reject, LF Reject, Noise Reject |
| Optional Serial Bus Triggers | I2C, SPI, RS-232/422/485/UART, USB, Ethernet, CAN, LIN, FlexRay, MIL-STD-1553, I2S/LJ/RJ/TDM (requires optional modules) |
RF Measurements
| Parameter | Value |
|---|---|
| Automated RF Measurements | Channel Power, Adjacent Channel Power Ratio (ACPR), Occupied Bandwidth (OBW) |
Measurements & Analysis
| Parameter | Value |
|---|---|
| Automatic Measurements | 29 standard |
Technology
Mixed Domain Oscilloscope (MDO)
Applications
Embedded system design, wireless integration, RF troubleshooting, and mixed-signal debugging