The Tektronix MSO2024 is a 200 MHz, 4-channel mixed signal oscilloscope equipped with 16 integrated digital channels. It features a 1 GS/s sample rate, 1 Mpoint record length across all channels, and advanced waveform analysis tools including the Wave Inspector navigation system and FilterVu variable low-pass filter.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 Host (front), USB 2.0 Device (rear), LAN (optional via DPO2CONN), VGA (optional via DPO2CONN) |
| Display | 7 in. (180 mm) widescreen TFT-LCD, 480 × 234 pixels |
| Standard Warranty | 5 years |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 V ±10% (50/60 Hz at 100-240 V, 400 Hz ±10% at 100-120 V), Max 80 W |
| Operating Temperature | 0 to +50 °C |
| Dimensions (W×H×D) | 377 mm × 180 mm × 134 mm |
| Weight | 3.6 |
Analog Vertical System
| Parameter | Value |
|---|---|
| Analog Input Channels | 4 |
| Analog Bandwidth (-3 dB) | 200 MHz |
| Calculated Rise Time (10% to 90%) | 2.1 ns |
| Input Coupling | AC, DC, GND |
| Input Impedance | 1 MΩ ± 2% in parallel with 11.5 pF ± 2 pF |
| Input Sensitivity Range | 2 mV/div to 5 V/div |
| Vertical Resolution | 8 bits |
| Max Input Voltage (1 MΩ) | 300 Vrms CAT II with peaks ≤ ±450 V |
| DC Gain Accuracy | ±3% for 10 mV/div to 5 V/div, ±4% for 2 mV/div to 5 mV/div |
| Channel-to-Channel Isolation | ≥ 100:1 at ≤ 200 MHz |
| Offset Range (2 mV/div to 200 mV/div) | ±1 V |
| Offset Range (206 mV/div to 5 V/div) | ±10 V |
Digital Vertical System
| Parameter | Value |
|---|---|
| Digital Channels | 16 |
| Threshold Grouping | Pod 1 (D7-D0) and Pod 2 (D15-D8) |
| Threshold Selections | TTL, CMOS, ECL, PECL, User Defined |
| Threshold Voltage Range | -15 V to +15 V |
| Threshold Accuracy | ±(100 mV + 3% of threshold setting) |
| Input Impedance (Digital Probe) | 101 kΩ in parallel with 8 pF (P6316) |
| Max Input Voltage (Digital Probe) | ±40 V |
| Minimum Voltage Swing | 500 mVp-p |
| Minimum Detectable Pulse Width | 5 ns |
| Maximum Toggle Rate | 250 MHz |
Horizontal System
| Parameter | Value |
|---|---|
| Maximum Real-time Sample Rate (Analog) | 1 GS/s |
| Maximum Sample Rate (Digital) | 1 GS/s (pod-independent) |
| Maximum Record Length (Analog Channels) | 1 Mpoint |
| Maximum Record Length (Digital Channels) | 1 Mpoint |
| Time Base Range | 2 ns/div to 100 s/div |
| Time Base Delay Range | -10 divisions to 5000 s |
| Channel-to-Channel Deskew Range | ±100 ns |
| Time Base Accuracy | ±25 ppm |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Auto, Normal, Single |
| Trigger Coupling | AC, DC, HF Reject, LF Reject, Noise Reject |
| Trigger Holdoff Range | 20 ns to 8 s |
| Edge Triggering | Rising, falling, or either slope on any channel |
| Runt Triggering | Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again |
| Logic Triggering | Trigger when any logical pattern of channels goes false or stays true for specified time |
| Setup and Hold Triggering | Trigger on violations of both setup time and hold time between clock and data on any input channels |
| Rise/Fall Time Triggering | Trigger on pulse edge rates that are faster or slower than specified |
| Video Triggering | Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals |
| Serial Bus Triggering Options | I2C, SPI, CAN, LIN, RS-232/422/485/UART (with appropriate hardware modules) |
| Trigger Level Range | ±4.96 divisions from center of screen |
Acquisition Modes
| Parameter | Value |
|---|---|
| Sample Mode | Acquire sampled values |
| Peak Detect Mode | Acquire narrow glitches down to 3.6 ns (analog) at all sweep speeds |
| Averaging Mode | Average 2 to 512 waveforms |
| Roll Mode | Scrolls waveforms right to left at sweep speeds slower than or equal to 40 ms/div |
Waveform Analysis & Measurements
| Parameter | Value |
|---|---|
| Automatic Measurements | 29 automatic measurements |
| Math Functions | Arithmetic (Add, Subtract, Multiply) and FFT |
| FFT Window Types | Hanning, Rectangular, Hamming, Blackman-Harris |
| Search and Mark Capabilities | Wave Inspector® automatic search, marking, and navigation |
Display & User Interface
| Parameter | Value |
|---|---|
| Display Type | Widescreen TFT-LCD color |
| Display Size (Diagonal) | 7 in (180 mm) |
| Display Resolution | 480 × 234 pixels (WQVGA) |
| Graticules | Full, Grid, Crosshair, Frame |
| Waveform Update Rate | 5,000 wfm/s |
Optional Integrated Instruments
| Parameter | Value |
|---|---|
| Frequency Counter Resolution | 6-digit trigger frequency counter |
Connectivity and Interfaces
| Parameter | Value |
|---|---|
| USB Host Ports (Front) | 1x USB 2.0 Host |
| USB Device Port (Rear) | 1x USB 2.0 Device |
| LAN Port (Ethernet) | Optional (via DPO2CONN connectivity module) |
| External Video Output Port | Optional (via DPO2CONN connectivity module) |
| Probe Interface | TekVPI Probe Interface |
Power Specifications
| Parameter | Value |
|---|---|
| Power Source Voltage | 100 to 240 V ±10% |
| Power Source Frequency | 45 Hz to 440 Hz (100 to 120 V), 45 Hz to 66 Hz (120 to 240 V) |
| Power Consumption | 80 W maximum |
Environmental & Compliance
| Parameter | Value |
|---|---|
| Non-Operating Temperature Range | -40 to +71 °C |
| Operating Humidity Range | High: 5% to 60% RH (at +40 to +50 °C); Low: 5% to 90% RH (at 0 to +40 °C) |
| Operating Altitude | Up to 3,000 m (9,843 ft) |
| Non-Operating Altitude | Up to 12,000 m (39,370 ft) |
| Electromagnetic Compatibility (EMC) | EC Council Directive 2004/108/EC |
| Safety Certifications | UL61010-1:2004, CAN/CSA-C22.2 No. 61010-1:2004, EN61010-1:2001 |
Physical Characteristics
| Parameter | Value |
|---|---|
| Width | 377 mm (14.9 in) |
| Height | 180 mm (7.1 in) |
| Depth | 134 mm (5.3 in) |
| Weight (Net) | 3.6 kg (7.9 lbs) |
| Weight (Shipping) | 6.2 kg (13.7 lbs) |
| Kensington Lock Slot | Standard rear-panel slot |
Vertical System
| Parameter | Value |
|---|---|
| Analog Bandwidth Limit | 20 MHz |
Interfaces
| Parameter | Value |
|---|---|
| GPIB Interface | Optional (via TEK-USB-488 adapter) |
| Ethernet and Video Out Ports | Optional (via DPO2CONN connectivity module) |
Waveform Measurements
| Parameter | Value |
|---|---|
| Measurement Statistics | Mean, Minimum, Maximum, Standard Deviation |
| Measurement Gating | Screen or Waveform Cursor |
Waveform Math
| Parameter | Value |
|---|---|
| Math Operators | Add, Subtract, Multiply |
Probes
| Parameter | Value |
|---|---|
| Standard Digital Probe | P6316 16-channel digital probe and accessory kit |
Included Accessories
| Parameter | Value |
|---|---|
| Standard Analog Probes | 4x P2221 (200 MHz, 1x/10x passive probes) |
Wave Inspector
| Parameter | Value |
|---|---|
| Wave Inspector Controls | Dedicated front-panel controls for zoom, pan, play/pause, active search, and user marks |
Expansion Slots
| Parameter | Value |
|---|---|
| Application Module Slots | 2 slots on the side of the instrument for optional application modules |
Acquisition System
| Parameter | Value |
|---|---|
| Envelope Mode | Min/max envelope of 2 to 512 or infinite acquisitions |
Technology
Digital Phosphor (DPO/MSO)
Applications
Mixed-Signal Debug, Embedded Design, Power Measurement, Serial Troubleshooting
Looking for the Tektronix MSO2024?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us