The Tektronix MSO4104 is a high-performance 1 GHz, 4-channel mixed signal oscilloscope from the MSO4000 series, integrating robust analog and digital analysis capabilities. With a 10.4-inch XGA color display, 16 integrated digital channels, a real-time sample rate of 5 GS/s on all channels, and a deep 10 Mpoints record length, it provides comprehensive debug capabilities for modern embedded systems.
Specifications
General
| Parameter | Value |
|---|---|
| Display | 10.4 in. (264 mm) liquid-crystal TFT color display, 1024 × 768 pixels (XGA) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 V ±10% (50/60 Hz at 100 to 240 V, 400 Hz at 100 to 132 V), 250 W maximum |
| Operating Temperature | 0 °C to +50 °C |
| Dimensions (W×H×D) | 439 mm × 229 mm × 137 mm |
| Weight | 5.0 |
| Cooling Clearance | 51 mm (2 in.) required on left side and rear of instrument |
| Security Lock Slot | Kensington-style lock slot |
Key Performance Specifications
| Parameter | Value |
|---|---|
| Analog Bandwidth | 1 GHz |
| Number of Analog Channels | 4 |
| Number of Digital Channels | 16 |
| Max Real-time Sample Rate (Analog) | 5 GS/s |
| Max Real-time Sample Rate (Digital) | 500 MS/s (2 ns resolution) |
| Max Record Length (Analog) | 10 Mpoints |
| Max Record Length (Digital) | 10 Mpoints |
| Max Waveform Capture Rate | >50,000 wfm/s |
| Hardware Bandwidth Limits | 20 MHz, 250 MHz |
Vertical System - Analog Channels
| Parameter | Value |
|---|---|
| Input Coupling | AC, DC, GND |
| Input Impedance | 1 MΩ ±1% || 13 pF ±2 pF, 50 Ω ±1% |
| Input Sensitivity Range (1 MΩ) | 1 mV/div to 10 V/div |
| Input Sensitivity Range (50 Ω) | 1 mV/div to 1 V/div |
| Vertical Resolution | 8 bits |
| Max Input Voltage (50 Ω) | 5 Vrms with peaks ≤ ±20 V |
| DC Gain Accuracy | ±1.5% for 2 mV/div to 10 V/div, ±3.0% for 1 mV/div |
| Channel-to-Channel Isolation | ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to rated bandwidth |
| Position Range | ±5 divisions |
Vertical System - Digital Channels
| Parameter | Value |
|---|---|
| Input Channels (Digital) | 16 (D0 to D15) |
| Input Impedance (Digital Probe) | 20 kΩ || 3 pF (P6516 probe) |
| Threshold Selections | TTL, CMOS, ECL, PECL, User-defined |
| Threshold Accuracy | ±(100 mV + 3% of threshold setting) |
| Max Input Voltage (Digital Probe) | ±40 V peak |
| Minimum Voltage Swing | 500 mV peak-to-peak |
Horizontal System
| Parameter | Value |
|---|---|
| Time Base Delay Time Range | -10 divisions to 5000 s |
| Channel-to-Channel Deskew Range | ±75 ns |
| Time Base Accuracy | ±5 ppm over any ≥1 ms interval |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Auto, Normal, Single |
| Trigger Coupling | DC, AC, HF Reject, LF Reject, Noise Reject |
| Trigger Holdoff Range | 20 ns to 8 s |
| Pulse Width Trigger | Trigger on width of positive or negative pulses that are >, <, =, or ≠ to a specified period of time (4 ns to 8 s) |
| Runt Trigger | Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again |
| Setup and Hold Trigger | Trigger on violations of setup time and hold time between clock and data present on any of the input channels |
| Rise and Fall Time Trigger | Trigger on pulse edge rates that are faster or slower than specified |
| Video Trigger | Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals |
Acquisition Modes
| Parameter | Value |
|---|---|
| Sample Mode | Acquire sampled values |
| Peak Detect Mode | Captures glitches as narrow as 200 ps at all sweep speeds |
| Averaging Mode | From 2 to 512 waveforms |
| Hi-Res Mode | Real-time boxcar averaging reduces random noise and increases vertical resolution |
| Roll Mode | Scrolls waveforms right to left across screen at sweep speeds slower than or equal to 40 ms/div |
Waveform Measurements and Analysis
| Parameter | Value |
|---|---|
| Measurement Statistics | Mean, Min, Max, Standard Deviation |
| Reference Levels | User-definable reference levels for automatic measurements, specified in percent or units |
| Gating | Isolate a specific occurrence within an acquisition for measurement, using either the screen or waveform cursors |
| FFT Window Functions | Rectangular, Hamming, Hanning, Blackman-Harris |
Display and Controls
| Parameter | Value |
|---|---|
| Waveform Styles | Vectors, Dots, Variable Persistence, Infinite Persistence |
| Graticules | Full, Grid, Cross Hair, Frame, IRE and mV |
Power and Environmental
| Parameter | Value |
|---|---|
| Operating Altitude | 3,000 m (10,000 ft.) |
Physical Specifications
| Parameter | Value |
|---|---|
| Dimensions (Height) | 229 mm |
| Dimensions (Width) | 439 mm |
| Dimensions (Depth) | 137 mm |
| Weight (Shipping) | 9.5 kg |
Compliance and Standards
| Parameter | Value |
|---|---|
| Safety Certifications | UL61010-1, CAN/CSA-C22.2 No. 61010-1, EN 61010-1 |
Connectivity
| Parameter | Value |
|---|---|
| USB Device Port | 1 x USB 2.0 Type-B on the rear panel for PictBridge printing or USBTMC control |
| LAN Port Connector | RJ-45 connector, 10/100Base-T Ethernet |
| Video Out Connector | DB-15 female D-Sub connector to show display on an external monitor |
Standard Accessories
| Parameter | Value |
|---|---|
| Standard Passive Probes | 4x P6139A (500 MHz, 10X, 8 pF) |
| Standard Digital Probe | 1x P6516 16-channel mixed-signal probe with accessory kit |
Power
| Parameter | Value |
|---|---|
| Power Consumption | 250 W maximum |
| Input Voltage Range | 100 to 240 V AC ±10% |
| Input Frequency Range | 47 to 66 Hz (100 to 240 V), 360 to 440 Hz (100 to 132 V) |
Search & Navigation
| Parameter | Value |
|---|---|
| Wave Inspector Navigation | Dedicated front-panel controls for zoom/pan, play/pause, search, and user marks |
Digital Channels
| Parameter | Value |
|---|---|
| MagniVu Timing Resolution | 60.6 ps |
| MagniVu Record Length | 10k points centered on the trigger |
Display
| Parameter | Value |
|---|---|
| Display Resolution | 1024 × 768 pixels (XGA) |
Interfaces
| Parameter | Value |
|---|---|
| Probe Interface | TekVPI Probe Interface |
| GPIB Interface | Optional (via TEK-USB-488 adapter) |
Software & Connectivity
| Parameter | Value |
|---|---|
| Software Support | OpenChoice Desktop, IVI Drivers, e*Scope Web-based Remote Control |
Technology
Mixed Signal Oscilloscope
Applications
Embedded design and debug, serial bus analysis, power measurement, and general electronic system troubleshooting
Looking for the Tektronix MSO4104?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us