The Tektronix TDS2024C is a 4-channel, 200 MHz Digital Storage Oscilloscope from the TDS2000C Series, featuring a digital real-time sampling rate of up to 2 GS/s on all channels, a 2.5k point record length, and built-in USB connectivity for advanced data logging and limit testing.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 Host (front panel), USB 2.0 Device (rear panel) |
| Display | 5.7 inches (144 mm) Active TFT Color Display |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 V ±10% (50/60 Hz), 115 V ±10% (400 Hz); 30 W max |
| Operating Temperature | 0 to +50 °C |
| Dimensions (W×H×D) | 326.3 mm × 158.0 mm × 124.2 mm |
| Weight | 2 kg |
Vertical System (Analog Channels)
| Parameter | Value |
|---|---|
| Analog Bandwidth (-3 dB) | 200 MHz |
| Number of Input Channels | 4 |
| Vertical Sensitivity Range | 2 mV to 5 V/div with calibrated fine adjustment |
| Vertical Resolution (A/D Converter) | 8 bits |
| Maximum Input Voltage | 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz |
| Hardware Bandwidth Limiters | 20 MHz |
Horizontal System & Acquisition
| Parameter | Value |
|---|---|
| Maximum Real-time Sample Rate | 2.0 GS/s on each channel |
| Maximum Record Length | 2.5 k points at all time bases |
| Time Base Range | 2.5 ns to 50 s/div |
Trigger System
| Parameter | Value |
|---|---|
| Advanced Triggers | Pulse Width Trigger, Line-selectable Video Trigger |
| Trigger Coupling | AC, DC, Noise Reject, HF Reject, LF Reject |
| Trigger Sources | CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line |
| External Trigger Input Range | ±1.2 V (EXT), ±6 V (EXT/5) |
| Trigger Sensitivity (Edge Trigger) | Internal: 1 div from DC to 10 MHz, 1.5 div from 10 MHz to 200 MHz; EXT: 100 mV (DC to 100 MHz), 150 mV (100 MHz to 200 MHz) |
Measurements & Analysis
| Parameter | Value |
|---|---|
| Automated Measurements | 16 automated measurements |
| Waveform Math Operators | FFT Analysis |
| Limit and Mask Testing | Built-in Waveform Limit Testing |
| Extended Data Logging | Automated, Extended Data Logging Feature |
General Features
| Parameter | Value |
|---|---|
| Autoset & Auto-ranging | Standard Autoset and Signal Auto-ranging |
| Built-in Help | Context-sensitive Help Menu |
| Probe Check Wizard | Standard |
| User Interface Language | Multiple-language User Interface |
Accessories & Ordering Options
| Parameter | Value |
|---|---|
| Standard Bundled Software | National Instruments LabVIEW SignalExpress TE Limited Edition, Tektronix OpenChoice Software |
Power & Physical Characteristics
| Parameter | Value |
|---|---|
| Depth | 124 mm (4.9 inches) |
| Weight (Imperial) | 4.4 lbs |
Vertical System
| Parameter | Value |
|---|---|
| Rise Time | 1.75 ns |
| Input Coupling | AC, DC, GND |
| Input Impedance | 1 MΩ ±2% in parallel with 20 pF ±3 pF |
| DC Vertical Accuracy | ±3% for 10 mV/div to 5 V/div, ±4% for 2 mV/div to 5 mV/div |
| Common Mode Rejection Ratio (CMRR) | 100:1 at 60 Hz, reducing to 10:1 at 50 MHz with equal Volts/div settings |
Horizontal System
| Parameter | Value |
|---|---|
| Horizontal Zoom | Vertically or horizontally expand or contract a live or stopped waveform |
| Time Base Accuracy | 50 ppm |
Acquisition System
| Parameter | Value |
|---|---|
| Acquisition Modes | Sample, Peak Detect, Average |
| Peak Detect Acquisition | Captures high-frequency and random glitches as narrow as 12 ns (typical) |
| Waveform Averaging | Selectable from 4, 16, 64, 128 waveforms |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -40 to +71 °C |
| Operating Altitude | Up to 3,000 m |
| Non-Operating Altitude | Up to 3,000 m |
| Operating Humidity | Up to 90% RH at or below +30 °C; up to 60% RH up to +50 °C |
| Non-Operating Humidity | Up to 90% RH at or below +30 °C; up to 60% RH up to +60 °C |
Compliance & Certifications
| Parameter | Value |
|---|---|
| Regulatory Safety Compliance | UL 61010-1:2004, CSA22.2 No. 61010-1:2004, EN 61010-1:2001, IEC 61010-1:2001 |
Physical & Accessories
| Parameter | Value |
|---|---|
| Standard Included Probes | TPP0201 (one per channel) 200 MHz 10X Passive Probes |
| Recommended Calibration Interval | 1 year |
Signal Processing & Math
| Parameter | Value |
|---|---|
| FFT Window Types | Hanning, Hamming, Blackman-Harris, Rectangular |
Connectivity & Control
| Parameter | Value |
|---|---|
| Optional GPIB Interface | Via TEK-USB-488 GPIB-to-USB Adapter |
Technology
Digital Storage Oscilloscope (DSO)
Applications
Electronic Design and Debugging, Manufacturing Test, Education, Service and Repair