The Tektronix TDS310 is a classic two-channel 50 MHz digital storage oscilloscope designed for benchtop and field service applications. Combining a responsive 200 MS/s real-time sample rate on both channels with a legacy 7-inch monochrome CRT raster display, it offers essential signal capture capabilities, automated waveform measurements, and robust trigger modes in a compact, portable format.

Specifications

General

ParameterValue
InterfacesGPIB, RS-232, Centronics parallel printer port (optional via Option 14)
Display7-inch monochrome CRT raster display, 640 × 480 pixel resolution

Physical

ParameterValue
Power Supply90 to 250 V AC, 45 to 440 Hz, max 65 W
Operating Temperature0 °C to +50 °C
Dimensions (W×H×D)362 mm × 165 mm × 472 mm

Vertical System - Analog Channels

ParameterValue
Analog Bandwidth (-3 dB)50 MHz
Calculated Rise Time (10% to 90%)≤ 7.0 ns
Number of Input Channels2
Input CouplingAC, DC, GND
Input Impedance1 MΩ in parallel with 20 pF
Input Sensitivity Range2 mV/div to 10 V/div (in 1-2-5 sequence)
Vertical Resolution8 bits (1 part in 256)
Maximum Input Voltage400 V (DC + Peak AC)
DC Gain Accuracy±2%
Hardware Bandwidth Limits20 MHz

Horizontal System

ParameterValue
Timebase Range10 ns/div to 5 s/div
Timebase Accuracy±0.01% (100 ppm)
Horizontal Zoomx10 magnification

Acquisition System

ParameterValue
Maximum Real-Time Sample Rate200 MS/s per channel simultaneously
Maximum Record Length (Memory Depth)1,000 points per channel
Acquisition ModesSample, Envelope, Average
Number of Digitizers2 independent digitizers (one per channel)

Trigger System

ParameterValue
Trigger SourcesChannel 1, Channel 2, Line, External
Trigger ModesAuto, Normal, Single Sequence
Trigger TypesEdge, Video (NTSC, PAL, SECAM)
External Trigger Input Impedance1 MΩ in parallel with 20 pF

Waveform Measurements and Analysis

ParameterValue
Automatic MeasurementsPeriod, Frequency, +Width, -Width, Rise Time, Fall Time, Peak-to-Peak, Amplitude, High, Low, Max, Min, Mean, Cycle RMS
Waveform Math OperatorsCH1 + CH2, CH1 - CH2, CH2 - CH1

Display and User Interface

ParameterValue
Waveform Display FormatsVector, Dot

Environmental and Compliance

ParameterValue
Operating AltitudeUp to 4,500 m (15,000 feet)
Operating HumidityUp to 95% RH at or below +30 °C

Performance

ParameterValue
Channel-to-Channel Isolation≥ 100:1 at 50 MHz

Triggering

ParameterValue
Trigger Holdoff Range250 ns to 10 s
Trigger Level Range (Internal)±12 divisions from screen center
Trigger Level Range (External)±4 V
Video Triggering FormatsNTSC, PAL, SECAM

Environmental

ParameterValue
Non-Operating Temperature-20 °C to +60 °C
Non-Operating AltitudeUp to 15,000 m (50,000 ft)
Non-Operating HumidityUp to 90% RH (≤ +40 °C), up to 60% RH (> +40 °C to +60 °C)
Vibration (Operating)0.31 g RMS, 5 Hz to 500 Hz, 10 min per axis
Vibration (Non-Operating)2.46 g RMS, 5 Hz to 500 Hz, 10 min per axis
Shock (Operating)50 g, 11 ms, half-sine

Power

ParameterValue
Line Frequency Range45 Hz to 440 Hz
Power Consumption≤ 65 W (90 VA)

Display

ParameterValue
Graticule8 × 10 divisions (1 div = 1 cm)

Acquisition

ParameterValue
Peak Detect Minimum Pulse Width10 ns

Interfaces

ParameterValue
Option 14 Video OutputVGA, female DB-15 connector, 31.5 kHz sync, 640 × 480

Storage

ParameterValue
Nonvolatile Setup Storage10 front-panel setups
Nonvolatile Waveform Storage2 reference waveforms

Connectivity

ParameterValue
GPIB Interface (Option 14)IEEE 488.2 compatible
RS-232 Interface (Option 14)9-pin D-sub male, up to 19.2 kbps
Printer Port (Option 14)DB-25 female, Centronics compatible
VGA Output (Option 14)15-pin D-sub, 640 x 480 monochrome VGA

Technology

Digital Storage Oscilloscope (DSO)

Applications

Electronic Design, Troubleshooting, General Purpose Test & Measurement