- Home
- Manufacturers
- Keysight Technologies (Agilent HP)
- Keysight Technologies (Agilent HP) — Analyzers
Keysight Technologies (Agilent HP) — Analyzers
68 models with full specifications in Analyzers.
This page summarizes how Keysight (formerly Agilent/HP) structures its analyzer offerings across spectrum/signal analyzers, vector network analyzers (VNAs), handheld FieldFox instruments, and purpose-built analyzers (impedance, semiconductor, EMC, communications). It is written for engineers and technical buyers who must pick an instrument by capability—frequency range, measurement set, portability, connector types, and dynamic-range or bandwidth needs—rather than brand positioning. Examples below illustrate where particular models sit in the range; the full model table (below) contains detailed specifications for each instrument.
- Highest PNA VNA range (example)
- E8361C: 10 MHz to 67 GHz
- Handheld max frequency (FieldFox example)
- N9952A: up to 50 GHz
- Benchtop general‑purpose signal analyzer
- N9000A: 9 kHz to 3.0 / 7.5 / 13.6 / 26.5 GHz (option dependent)
- EMC analyzer coverage & detectors
- E7405A: 9 kHz to 26.5 GHz; Peak, Quasi‑Peak, Average detectors
All models
| Model | Type | Operating Temperature | Power Supply | Dimensions (W×H×D) |
|---|---|---|---|---|
| 85029B | Verification Kits | 20 °C to 26 °C | — | — |
| 85053B | Verification Kits | 20 °C to 26 °C | — | — |
| 8595A | Frequency | 0 °C to +55 °C | 86 to 127 V AC / 195 to 253 V AC, 47 to 66 Hz (up to 440 Hz optional), <150 VA | 325 mm × 163 mm × 427 mm |
| 86108B | Waveform | 10 °C to 40 °C | Powered directly through mainframe plug-in interface slots | — |
| N4903A | *misc | 5 °C to 40 °C | 100 to 240 V AC (±10%), 50 to 60 Hz / 400 Hz, 450 VA maximum | 424 mm × 222 mm × 563 mm |
| N6785A | *misc | 0 to 55 °C | Supplied by the N6700 series mainframe backplane | 70.4 mm x 47.3 mm x 343.4 mm |
| N9951A | Impedance | -10 to 55 °C | 15 VDC (external AC to DC adapter, 100 to 240 VAC, 50 to 60 Hz input; 10.8 V, 4.6 Ah Lithium-Ion battery) | 292 mm x 188 mm x 72 mm |
| 1661C | *misc | 0 to 55 °C | 115/230 V AC (-22% to +10%), 48-66 Hz, 200 W maximum | 425 mm × 188 mm × 432 mm |
| 1663C | *misc | 0 to +55 °C | 115/230 V AC (+10%/-25%), 48-66 Hz, 200 W maximum | 425 mm x 198 mm x 366 mm |
| 16804A | *misc | 0 to +40 °C | 100 - 240 V AC (±10%), 48 - 66 Hz, 615 W max | 426.5 mm x 340.0 mm x 396.2 mm |
| 54620C | *misc | 0 to +55 °C | 100 - 240 VAC (±10%), 45 - 440 Hz, 80 VA max | 322 mm × 172 mm × 317 mm |
| 85053A | Verification Kits | 20 °C to 26 °C | — | — |
| 8703A | Lightwave | 0 °C to +55 °C | 90 to 132 V / 198 to 264 V, 47 to 66 Hz | 425 mm × 222 mm × 546 mm |
| 8703B | Lightwave | 0 to 55 °C | 90 to 132 V AC / 198 to 264 V AC, 47 to 66 Hz | 425 mm × 267 mm × 502 mm |
| 8720ET | *misc | 0 to 55 °C | 90 to 132 VAC / 198 to 264 VAC, 47 to 66 Hz | 425 mm × 222 mm × 457 mm |
| B1500A | Semiconductor | 5 °C to 40 °C | 100 V to 240 V AC (±10%), 50 Hz to 60 Hz (±10%), maximum 900 VA | 426 mm × 330 mm × 575 mm |
| E4991B | Impedance | 5 °C to 40 °C | 90 V to 264 V AC, 47 Hz to 63 Hz, 300 VA maximum power consumption | 426 mm × 185 mm × 415 mm (main unit) |
| E8364A | *misc | 5 °C to +40 °C | 100 to 240 VAC (±10%), 47 to 63 Hz, 350 W maximum | 425 mm × 244 mm × 498 mm |
| N4692D | Impedance | 15 °C to 35 °C (operating range); 20 °C to 30 °C (calibrated specifications range) | USB bus-powered (5 VDC, < 500 mA) | 72 mm × 22 mm × 141 mm |
| N4693D | Impedance | 20 °C to 30 °C | USB bus-powered | 111 mm × 22 mm × 128 mm |
Looking for Keysight Technologies (Agilent HP) — Analyzers?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us
How the range is organized
Keysight groups analyzers by the measurement domain and intended use. Broad categories visible in this lineup are:
- Benchtop spectrum and signal analyzers for lab and service work. Examples include the N9000A CXA class (configurable to different top-end frequencies) and production/service analyzers like the N9320B/N9340A family for 3 GHz-class needs.
- High-performance VNAs in the Microwave PNA series for demanding S‑parameter work (E8362C, E8361C). These instruments list sweep point counts, connector types, and dynamic range figures appropriate for component and network verification.
- Rugged handheld FieldFox instruments (N9914A, N9915A, N9917A/B, N9918A, N9952A) that combine CAT, VNA and SA functions for field installation, antenna and cable test, and on-site VNA measurements.
- Specialized analyzers for impedance/materials, semiconductor parameter characterization, EMC and communications test (E4990A/E4294A, 4156C/4155B/4155A, E7405A, 37718A).
What distinguishes each family
Focus and notable specification examples:
-
PNA VNAs (E8362C, E8361C): built for accuracy and dynamic range. The E8362C specifies up to 123 dB dynamic range and a multi‑channel/high‑point sweep capability; the E8361C extends frequency coverage to 67 GHz and uses 1.85 mm test ports.
-
Benchtop spectrum/signal analyzers (N9000A, N9320B): offered with different maximum frequencies and RBW/VBW choices. The N9000A is positioned as an economical, general‑purpose CXA analyzer with RBW down to 1 Hz and analysis bandwidth options.
-
FieldFox handhelds (N9914A, N9915A, N9917A/B, N9918A, N9952A): combine multiple measurement modes (CAT, VNA, SA) with rugged enclosures and varied frequency coverage — from single‑digit GHz up to 50 GHz on configured units. Connector types and ECal support differ (for example, N9917B uses Type‑N ports; N9952A uses 2.4 mm ports where fitted).
-
Specialized instruments: impedance analyzers such as the E4990A and 4294A provide dedicated frequency ranges and DC bias capability; semiconductor analyzers (4156C/4155B) provide multiple SMU channels and sub‑microamp to femtoamp resolution for device characterization; EMC analyzers like the E7405A supply CISPR bandwidths and quasi‑peak detectors.
Practical selection guidance
Match the measurement task to these concrete criteria:
-
Frequency coverage: pick an instrument whose stated frequency range covers the DUT and measurement bandwidth (examples: use an E8361C when S‑parameter test must extend to 67 GHz; consider N9952A FieldFox when handheld testing requires up to 50 GHz).
-
Measurement set and instrumentation density: if you need only spectrum and basic signal analysis at up to 3 GHz, compact benchtop models such as the N9320B or handheld N9340A/N9340 family are relevant. If you need VNA capability plus cable/antenna analysis in the field, a FieldFox (N9915A–N9918A series) combines both.
-
Accuracy, dynamic range and ports: for component characterization and high dynamic range S‑parameter measurement, PNA series units (E8362C, E8361C) specify high dynamic range and precise connectors (3.5 mm or 1.85 mm) and large sweep point capability.
-
Portability and environment: handheld FieldFox models list operating-temperature and IP/shock compliance details; choose them when bench space or transportability is a requirement.
-
Specialized needs: pick an impedance analyzer (E4990A, 4294A) for materials and component impedance over dedicated frequency bands, or a semiconductor parameter analyzer (4156C, 4155B) when SMU count, voltage/current ranges and resolution matter.
Connector, interfaces and expandability to check
Before committing, verify the specific model option and connector set you need:
-
Test ports and calibration: PNA VNAs specify connector types (E8362C: 3.5 mm male; E8361C: 1.85 mm male). Field units list port type (N9917B: Type‑N female; N9952A: 2.4 mm male on test ports).
-
Bandwidth and real‑time capability: some handhelds and field analyzers list options for real‑time bandwidth (N9952A: Maximum Real‑Time Bandwidth 10 MHz with Option 350).
-
Digital and remote control: mainstream Keysight analyzers include USB, LAN, GPIB or SCPI command support; confirm the interfaces required for automated test or data logging.
Frequently asked questions
- When should I choose a FieldFox handheld vs a benchtop spectrum analyzer?
- Choose a FieldFox when you need multifunction field measurements (CAT, VNA, SA) and ruggedness. FieldFox models span options such as 30 kHz to 9 GHz (N9915A), 30 kHz to 18 GHz (N9917A), up to 26.5 GHz (N9918A) and up to 50 GHz (N9952A). Choose a benchtop analyzer like the N9000A or N9320B when lab accuracy, larger displays, and bench‑oriented interfaces are more important.
- Which Keysight VNA should I consider for millimeter‑wave component work?
- For the widest stated frequency coverage in this list, the E8361C Microwave PNA is specified from 10 MHz to 67 GHz and uses 1.85 mm test ports. The E8362C is a PNA variant offering a high dynamic range (123 dB) for demanding network measurements.
- Which model is intended for EMI precompliance and what to check?
- The E7405A is presented as a portable EMC analyzer covering 9 kHz to 26.5 GHz and lists EMI detectors (Peak, Quasi‑Peak, Average) plus CISPR RBW settings. Confirm the detector modes and CISPR bandwidths needed for your tests against the model's listed capabilities.