Keysight Technologies (Agilent HP) Oscilloscopes

109 models with full specifications in Oscilloscopes.

This page summarizes Keysight (formerly Agilent/HP) oscilloscopes across the Infiniium, InfiniiVision and DSA/DCA platforms and explains how the range is structured for lab and compliance work. It is written for engineers and technical buyers who need to match instrument capabilities (bandwidth, sample rate, channel count, modular analysis and mixed‑signal support) to measurement tasks such as serial‑link eye and jitter analysis, embedded system debug, or real‑time signal integrity work. The copy names representative models to illustrate where different products fit; detailed specifications for every model are in the adjacent table.

Modular DCA bandwidth
>80 GHz (module dependent, 86100 series mainframes)
Top real‑time analog bandwidth
10 GHz (DSO81004B)
Mixed‑signal digital channels
Up to 16 digital channels (MSOX6004A, MSO9404A, others)
ADC vertical resolution examples
14‑bit (DCA mainframes), 10‑bit (MSOS404A), 8‑bit (many DSOs/DSAs)

All models

ModelTypeOperating TemperatureDisplayPower Supply
83483A*misc15 °C to 35 °C (for full accuracy) / 10 °C to 40 °C (operating)None (utilizes mainframe display)Powered directly by the mainframe slot
DSA90254A*misc5 °C to +40 °C12.1-inch color XGA TFT-LCD with touch screen100 - 240 VAC, 50/60 Hz, maximum 800 W
DSO5032ADualTrace0 °C to +55 °C6.3-inch diagonal color TFT LCD, 1024 x 768 pixels (XGA), 256 levels of intensity grading100-240 V AC, 50/60 Hz; 100-120 V AC, 400 Hz; 120 W maximum power consumption
DSO6012A*misc0 to +55 °C6.3-inch color TFT active matrix VGA (640 x 480) display with 256 intensity levels100 - 240 VAC ±10% auto-ranging, 47 - 440 Hz, 120 W maximum power consumption
DSO6014ADigital0 to +55 °C6.3-inch (160 mm) diagonal color TFT LCD, 640 x 480 VGA resolution, 256 levels of intensity grading100 to 240 VAC (±10%), 50/60 Hz, or 100 to 120 VAC, 400 Hz; 120 W maximum
DSO6032ADualTrace0 to +55 °C6.3-inch diagonal VGA (640 x 480) color active matrix LCD with 256 levels of intensity and 100,000 waveforms/sec update rate100 - 240 VAC, 50/60/400 Hz, 120 W maximum; optional internal battery (Option BAT)
DSO6104LDSO0 °C to 50 °CNone (requires external monitor via rear XGA out or remote web browser graphical interface)100 to 240 VAC, 50 to 60 Hz (automatic selection), 80 W maximum
DSO80204B*misc———
DSO8064ADSO5 to 40 °C12.1-inch color XGA TFT-LCD with 256-level intensity-graded touch screen100 - 240 V AC (±10%) at 47 - 440 Hz, max 440 W
DSO80804B*misc5 °C to +40 °C8.4-inch XGA color active-matrix TFT-LCD touch screen, 1024 x 768 resolution, with 256-level intensity grading100 - 240 VAC (±10%), 47 - 63 Hz, 550 W maximum
MSO6014AMixed Signal 0 to +55 °C6.3-inch diagonal color TFT LCD, VGA (640 x 480) resolution, 256 intensity levels—
MSO6032AMixed Signal 0 to +55 °C6.3-inch high-definition color LCD with 256 levels of intensity100-240 VAC, 50/60 Hz, 120 W maximum
MSO7104BMixed Signal 0 °C to +55 °C12.1-inch diagonal color TFT LCD with XGA (1024 x 768) resolution and 256 intensity levels100 - 120 V (50/60/400 Hz) / 100 - 240 V (50/60 Hz) auto-ranging, 120 W maximum power consumption
MXR608A*misc5 to 40 °C15.6-inch capacitive multi-touch screen, Full HD (1920 x 1080) resolution100 to 240 VAC (±10%) at 50/60 Hz, 500 W maximum power consumption
UXR0134A*misc5 to 40 °C15.4-inch capacitive touch screen, Full HD (1920 x 1080) resolution100 to 240 VAC, 50/60 Hz, up to 1420 VA maximum
54542CDigital0 to +55 °CColor active-matrix TFT LCD flat-panel display90 to 132 V AC or 198 to 264 V AC, 48 to 66 Hz, 350 VA maximum
54600ADigital0 to +55 °C7-inch monochrome raster CRT100 - 240 VAC (±10%), 48 - 440 Hz, 120 VA maximum
54602B*misc0 to +55 °C7-inch monochrome raster CRT100 to 240 VAC (±10%), 45 to 440 Hz, 120 VA maximum
54616BDigital0 to +55 °C7-inch monochrome green phosphor CRT raster display100-240 VAC (±10%), 45-440 Hz, 220 VA maximum
54616C*misc0 to +55 °CColor CRT display (using liquid crystal color shutter technology)100-240 VAC (±10%), 45-440 Hz
54645A*misc0 °C to +55 °C7-inch monochrome raster CRT100 to 240 VAC (±10%), 45 to 440 Hz, 100 VA max
54750AMainframe15 to 35 °C (operating)9-inch color CRT90 to 132 V AC / 198 to 264 V AC, 48 to 66 Hz, 650 VA maximum
54815A*misc+10 °C to +40 °C7.5-inch color flat-panel TFT-LCD, 640 x 480 resolution100-240 VAC (±10%), 47-440 Hz, Max 390 W
54820ADigital0 °C to +50 °C8.4-inch color active-matrix TFT-LCD, 640 × 480 resolution100–240 VAC (±10%), 47–440 Hz, 390 W maximum power consumption
54825ADigital5 to +40 °C8.4-inch active-matrix TFT color LCD, 640 × 480 resolution100–240 VAC, 47–440 Hz, 390 W maximum
54846B*misc5 °C to +40 °C10.4-inch color active-matrix TFT-LCD, 640 × 480 resolution100-240 VAC (±10%), 47-440 Hz, 390 W maximum power consumption
54853ADigital5°C to +40°C10.4-inch active-matrix TFT-LCD, SVGA (800 × 600) resolution100–240 VAC (±10%), 47–440 Hz, max 550 W
DSAX92004A*misc5 °C to +40 °C12.1-inch diagonal color TFT-LCD touchscreen, 1024 x 768 pixels100 - 240 VAC ±10% at 50/60 Hz, maximum power consumption 1100 VA
DSAX93204A*misc5 °C to +40 °C12.1-inch color XGA TFT-LCD capacitive touchscreen, 1024 x 768 pixels100 - 240 VAC at 50/60 Hz, power consumption 1100 VA maximum
DSO3202A*misc0 °C to 40 °C15-cm (5.7-inch) color LCD, 320 x 240 pixel resolution100 to 240 VAC (±10%), 50/60 Hz (±10%) or 400 Hz, 50 VA max
DSO6014L*misc0 to +50 °CNone (headless 1U rackmount), XGA video output for external monitor100 - 240 V AC, 50/60 Hz; or 100 - 120 V AC, 400 Hz; 80 W maximum
DSO6054L*misc0 °C to +50 °CNone (headless, external monitor support via XGA port or remote graphical Web interface)100 - 240 V AC, 50/60 Hz, automatic selection
DSO7104BDSO0 to +50 °C12.1-inch diagonal color TFT LCD, XGA (1024 x 768) resolution, 256-level intensity gradation100-120 V (50/60/400 Hz), 100-240 V (50/60 Hz) auto-ranging; 120 W maximum power consumption
DSO80304B*misc5 °C to +40 °C10.4-inch color XGA TFT touch screen, 1024 x 768 resolution, 256-level intensity grading100 - 240 VAC (±10%), 47 - 63 Hz, 550 W maximum power consumption
DSO91304A*misc5 °C to +40 °C12.1-inch XGA TFT-LCD touchscreen, 1024 x 768 resolution100 - 240 V AC (±10%) at 50/60 Hz, Max power consumption 800 W
DSOX3034ADSO0 to +55 °C8.5-inch WVGA with 64 levels of intensity grading100-120 V (50/60/400 Hz), 100-240 V (50/60 Hz), 100 W max
MSO6012AMixed Signal 0 to +55 °C6.3-inch (160 mm) diagonal color flat-panel TFT-LCD, 320 × 240 pixels (QVGA) with 256 levels of intensity100-240 VAC, 50/60 Hz; 100-120 VAC at 400 Hz; Auto-ranging; 120 W maximum
MSO7054AMixed Signal 0 °C to +55 °C12.1-inch diagonal liquid crystal display (LCD) with XGA (1024 x 768) resolution, 256 intensity levels100-240 V AC, 50/60 Hz; 100-120 V AC, 400 Hz; 120 W maximum power consumption
MSO7104AMixed Signal 0 to +55 °C12.1-inch color TFT LCD, XGA (1024 x 768), 256 levels of intensity100-120 V AC (50/60/400 Hz), 100-240 V AC (50/60 Hz), Max 120 W
N2803A*misc5 °C to 40 °C—Powered directly by Keysight Infiniium oscilloscope through AutoProbe II interface
1671GAnalog0 to 50 °CColor flat-panel VGA display115 / 230 V AC (±20%), 48 - 66 Hz, 315 W max
54100D*misc0 °C to +55 °C9-inch monochrome CRT115 / 230 V AC (nominal), 48 - 66 Hz, 200 W max
54110DDigital0 °C to +55 °C9-inch color CRT115/230 Vac (+15% / -25%), 48-66 Hz
54600BDigital0 to +55 °C7-inch monochrome CRT raster display with 500 x 256 pixel resolution100-240 VAC (±10%), 45-440 Hz, automatic selection, 75 W maximum power consumption
54641DMixed Signal 0 to +557-inch monochrome CRT with 32 levels of intensity100 - 240 V AC (±10%), 47 - 440 Hz, 110 W max
54642ADSO0 to +55 °C5.7-inch monochrome LCD with 32 levels of intensity, 320 × 240 resolution100 - 240 VAC (±10%), 47 - 440 Hz, 110 W maximum
54831B*misc5 °C to +40 °C8.4-inch color TFT-LCD, 640 × 480 resolution100-240 VAC (±10%), 47-440 Hz, Max 390 W
54835ADigital0 to +50 °C8.4-inch active-matrix color TFT-LCD, 640 × 480 resolution100 - 240 VAC (±10%), 47 - 440 Hz, 390 W maximum power consumption

Looking for Keysight Technologies (Agilent HP) Oscilloscopes?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us

How the Keysight oscilloscope range is structured

Keysight’s oscilloscope offering in the table breaks down into a few distinct approaches:

  • Modular sampling mainframes (Infiniium DCA / DCA‑X): mainframes such as the 86100C and 86100D accept plug‑in modules to reach very high effective bandwidths and provide dedicated digital communications analysis capabilities (pattern lock, extinction ratio, automated eye/jitter metrics). The 86100D adds features such as FlexDCA and DCA‑J user interfaces and precision timebase options.

  • High‑performance real‑time Infiniium DSOs (Infiniium 80000B/8000/5000 families): fixed real‑time analog bandwidth instruments (for example DSO81004B at 10 GHz, DSO80604B at 6 GHz, DSO80404B at 4 GHz) that emphasize instantaneous capture, low noise and low jitter for signal integrity measurements.

  • Digital Signal Analyzers (DSA / Infiniium 90000A Series): models such as DSA90404A, DSA90804A and DSA91304A combine very high sample rates, deep memory and serial‑data analysis toolsets (SDA, EZJIT+) aimed at characterizing and debugging high‑speed serial links.

  • Mixed‑signal and midrange InfiniiVision instruments: MSO and MSOX models (for example MSOX6004A, MSO9404A, MSOX4154A, MSOX3054A) provide mixed analog+digital capability with 16 logic channels and are positioned for embedded design debug and throughput‑oriented troubleshooting.

What distinguishes each family

Modular DCA mainframes (86100 series)

  • Purpose: measurement of very high data‑rate serial links, exhaustive eye and jitter analysis and TDR/TDT when fitted with appropriate modules. Example models: 86100C and 86100D. The 86100C provides a 14‑bit mainframe A/D and supports extremely high module bandwidths; the 86100D is code‑compatible with earlier DCA modules and adds dual UI options and precision timebase capability.

Real‑time Infiniium 80000B / 8000 / 5000 families

  • Purpose: real‑time capture with industry‑grade signal integrity and low noise. Example models: DSO81004B (10 GHz real‑time bandwidth), DSO80604B (6 GHz), DSO80404B (4 GHz). These instruments provide low noise floors and calculated rise time specs appropriate for high‑speed analog/digital measurements.

DSA (Infiniium 90000A Series)

  • Purpose: combine high sample rates, deep memory and serial‑data analysis. Examples: DSA90404A, DSA90804A, DSA91304A. These models include SDA and EZJIT+ analysis, high real‑time sampling rates per channel and long record lengths to support jitter decomposition and eye diagrams.

InfiniiVision MSO / MSOX series

  • Purpose: mixed‑signal debug for embedded and digital systems. Examples: MSOX6004A (1 GHz base bandwidth, 16 digital channels, upgradeable bandwidth), MSO9404A (4 GHz MSO), MSOX4154A (1.5 GHz MSO in 4000 X‑Series). These instruments emphasize waveform update rate, MegaZoom memory architectures and integrated logic channel views.

How to choose between Keysight models

Select on the basis of measurement objective and interface requirements rather than feature lists alone:

  • Bandwidth versus real‑time capture: choose modular DCA mainframes (86100 series) when required bandwidth exceeds single‑instrument real‑time limits and when comprehensive eye/jitter/TDR analysis is needed. Choose an Infiniium real‑time DSO (DSO8xxx/DSO80404B/DSO80604B/DSO81004B) when deterministic, single‑shot capture and low noise/jitter are primary.

  • Serial‑link analysis and jitter decomposition: the DSA family (DSA90404A, DSA90804A, DSA91304A) and DCA mainframes include SDA and EZJIT+ analysis and clock recovery tools; use these when standard compliance and jitter separation are required.

  • Embedded and mixed‑signal debug: select an MSO/MSOX model (MSOX6004A, MSO9404A, MSOX4154A, MSOX3054A) when digital timing and protocol decode must be combined with analog waveform debug; note the integrated 16 digital channels on many MSO models.

  • Practical tradeoffs: consider number of analog channels, digital‑channel count, record length and waveform update rate. If deep memory and long records are needed for packet capture or long acquisitions, prefer models that list larger per‑channel memory depth in the specification table.

Frequently asked questions

Which Keysight instruments are intended for the highest‑bandwidth serial link measurements?
The Infiniium DCA modular mainframes (examples: 86100C and 86100D) are designed for the highest effective bandwidths via plug‑in modules (bandwidths in excess of 80 GHz are achievable with appropriate modules) and include dedicated eye and jitter test capabilities.
When should a DSA model be chosen instead of a real‑time DSO?
Choose a DSA (for example DSA90404A, DSA90804A, DSA91304A) when the task requires high per‑channel real‑time sample rates, deep memory and the bundled serial‑data analysis toolset (SDA, EZJIT+) for jitter decomposition and eye diagrams. Real‑time DSOs prioritize single‑shot capture and low noise for time‑domain troubleshooting.
Do Keysight midrange scopes support mixed‑signal debugging?
Yes. InfiniiVision MSO/MSOX models such as MSOX6004A, MSO9404A and MSOX4154A provide integrated analog channels plus 16 digital channels and are intended for embedded mixed‑signal debug with logic timing and protocol views.