Tektronix Oscilloscopes

175 models with full specifications in Oscilloscopes.

This page explains how Tektronix’s oscilloscope portfolio is organized and how to match a model to measurement tasks common in engineering and test labs. It summarizes the families you’ll see in the full model table (TDS, DPO/DPO7000, MSO, MDO and the modular DSA8200 mainframe), highlights features that distinguish certain instruments (FlexChannel mixed‑signal inputs, integrated RF spectrum analyzer, high sample‑rate DPO platforms), and gives practical guidance on choosing by bandwidth, sample rate, channel count and mixed‑signal needs. Use this as a technician‑level guide to narrow the list before you inspect the individual specifications in the model table.

Bandwidth span
60 MHz to 70+ GHz (across listed models and modular options)
Channel counts
2, 4, 6, or 8 analog channels; many models offer additional digital channels or FlexChannel configurations
Max real‑time sample rate
Up to 40 GS/s (model‑dependent)
Maximum record length
Up to 1 Gpoint (model‑dependent)

All models

ModelTypeDimensions (W×H×D)Operating TemperaturePower Supply
2465Analog329 mm × 136 mm × 440 mm-15 °C to +55 °C90 - 250 V AC, 48 - 440 Hz, 120 W maximum
DPO3032Digital416.6 mm × 203.2 mm × 137.2 mm0 °C to +50 °C100 to 240 V ±10% (50/60 Hz), 115 V ±10% (400 Hz), 120 W maximum
DPO3052Digital416.6 × 203.2 × 137.2 mm0 to +50 °C100 to 240 V AC ±10% (50/60 Hz), 100 to 132 V AC (400 Hz), < 120 W power consumption
DPO4034BDigital439 mm × 229 mm × 137 mm (17.3 in. × 9.0 in. × 5.4 in.)0 to +50 °C100 to 240 V ±10% (50 to 60 Hz), 115 V ±10% (400 Hz); 225 W maximum
DPO70604Digital451 mm × 298 mm × 489 mm5 °C to +45 °C100 to 240 V AC ±10%, 50/60 Hz; 115 V AC ±10%, 400 Hz
DPO73304DX*misc457 mm × 298 mm × 513 mm5 °C to +45 °C100 to 240 V AC ±10% (50/60 Hz), 115 V AC ±10% (400 Hz), <980 VA maximum
DSA70804C*misc451 × 298 × 4895 to 45100 to 240 V AC ±10% at 50 to 60 Hz, or 115 V AC ±10% at 400 Hz; <1200 VA maximum
DSA71604B*misc451 × 298 × 489 mm5 to 45 °C100 to 240 V AC ±10% (50/60 Hz), 115 V AC ±10% (400 Hz), power consumption <1200 VA
DSA72004C*misc457 mm × 298 mm × 513 mm5 °C to +45 °C100 to 240 V AC ±10% at 50/60 Hz, or 115 V AC ±10% at 400 Hz; <980 VA maximum
DSA73304D*misc451 mm × 298 mm × 489 mm5 °C to 45 °C100 to 240 V AC ±10% (50 to 60 Hz), 115 V AC ±10% (400 Hz), < 1200 VA maximum power consumption
MDO3104Mixed Signal 379 mm × 203 mm × 147 mm0 °C to +50 °C100 to 240 V ±10% (50 to 60 Hz), 115 V ±10% (400 Hz), 120 W maximum power consumption
MSO2024Mixed Signal 377 mm × 180 mm × 134 mm0 to +50 °C100 to 240 V ±10% (50/60 Hz at 100-240 V, 400 Hz ±10% at 100-120 V), Max 80 W
MSO71254CMixed Signal 451 × 298 × 489 mm5 to 45 °C100 to 240 V AC ±10% (50/60 Hz), 115 V AC ±10% (400 Hz), <980 VA max
MSO71604CMixed Signal 468 mm x 298 mm x 489 mm5 to 45100 to 240 V AC +/-10% (50/60 Hz), 115 V AC +/-10% (400 Hz), <1200 VA maximum power consumption
MSO73304DXDigital/Analog483 mm × 298 mm × 489 mm5 °C to 45 °C100 to 240 V AC ±10% (50/60 Hz), 115 V AC ±10% (400 Hz), <1200 VA max power consumption
TBS1202B*misc326.3 mm x 158.0 mm x 124.2 mm0 to +50 °C100 to 240 V AC ±10% (50/60 Hz, 100 to 120 V AC at 400 Hz), 30 W maximum
TDS2002*misc323.6 mm × 151.4 mm × 124.5 mm0 °C to +50 °C100 to 240 VAC RMS ±10% (47 to 440 Hz at 115 VAC, 47 to 63 Hz at 230 VAC), < 30 W
TDS2002BDigital326.3 mm × 158.0 mm × 124.2 mm0 to 50 °C100 to 240 V AC ±10% (45 to 66 Hz) or 115 V AC ±10% (360 to 440 Hz), power consumption less than 30 W
TDS2022Digital323.6 mm × 151.4 mm × 124.5 mm0 to +50 °C100 to 240 VAC (±10%), 47 to 440 Hz (at 115 V), 47 to 63 Hz (at 230 V), <30 W power consumption
TDS2024CDSO326.3 mm × 158.0 mm × 124.2 mm0 to +50 °C100 to 240 V ±10% (50/60 Hz), 115 V ±10% (400 Hz); 30 W max
TDS3012*misc375 mm × 176 mm × 149 mm0 °C to +50 °C90 V to 250 V AC RMS, 47 Hz to 440 Hz (90 V to 132 V), 47 Hz to 63 Hz (132 V to 250 V), 75 W max; optional battery operation
TDS3024BDigital375 mm × 176 mm × 149 mm0 °C to +50 °C100 V to 240 V AC ±10% (50/60 Hz), 115 V AC ±10% (400 Hz), 75 W max; optional battery pack (TDS3BATB)
TDS520D*misc448 × 193 × 471+4 to +50 °C (with floppy drive)90 to 250 V AC RMS, 45 to 440 Hz, power consumption < 300 W
TDS640Digital445 mm × 193 mm × 434 mm0 to +50 °C90 to 250 V RMS, 45 Hz to 440 Hz, <300 W
TDS684A*misc448 mm × 193 mm × 547 mm4 to +50 °C90 to 250 V RMS, 45 to 440 Hz, max 350 W
TDS7154*misc455 mm × 277 mm × 425 mm (excluding feet and accessories)+5 °C to +45 °C100 to 240 V RMS (±10%), 47 to 63 Hz; 115 V RMS (±10%), 360 to 440 Hz; CAT II; power consumption <300 W
TDS8000BDigital457 mm × 343 mm × 419 mm+10 to +40 °C90 to 250 V AC, 45 to 66 Hz, <300 W typical
TDS820Digital445 mm × 193 mm × 448 mm0 to +50 °C90 to 250 V AC RMS, 45 to 440 Hz, 300 W maximum
THS720PHandheld177 mm × 217 mm × 51 mm0 °C to +50 °CNiCd rechargeable battery pack or external AC adapter
TPS2012Digital336.0 mm × 161.0 mm × 130.0 mm0 °C to +50 °CExternal AC adapter (100 to 240 VAC, 50/60 Hz to 15 VDC output) or up to 2 rechargeable Lithium-Ion batteries
TPS2014DSO336 mm × 161 mm × 130 mm (13.24 in × 6.33 in × 5.10 in)0 °C to +50 °CAC Adapter (90 - 250 V AC, 50/60 Hz) or Li-Ion Battery Packs (TPSBAT)

Looking for Tektronix Oscilloscopes?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us

How the Tektronix range is structured

Tektronix supplies multiple product groups that target different use cases. The TDS and older TDSxxx series are general‑purpose digital phosphor and digital storage oscilloscopes with portable bench form factors (examples in the line include compact 2‑channel models and 4‑channel models such as TDS210 and TDS3054B). The DPO/DPO7000 class is positioned for higher acquisition performance, deeper memory and Windows‑based analysis on larger displays (examples: DPO7104, DPO7254, DPO7354). MSO families combine analog and logic in the same instrument; models such as MSO58 and MSO64 use FlexChannel or similar architectures to let inputs serve as analog or as multiple digital channels. The MDO series integrates a dedicated RF/spectrum channel for time‑correlated analog/digital/RF debugging (examples: MDO3054, MDO4054-6, MDO4104-6). For very high bandwidth or modular sampling needs the DSA8200 mainframe accepts specialized modules for the highest frequency measurements.

Key differentiators to watch for

Bandwidth and sample rate: Tektronix products cover wide performance points. Low‑end and portable models list bandwidths starting in the tens of MHz (for example TDS210), bench DPO and DPO7000 models provide GHz‑class bandwidth and very high sample rates (DPO7254, DPO7354), and modular systems such as the DSA8200 support much higher RF bandwidths via instrumentation modules. Mixed signal and FlexChannel: MSO models (MSO58, MSO64, MSO46) let a single front‑end be used as an analog input or multiple digital logic inputs; the MSO58 explicitly documents 8 FlexChannel inputs that can each provide either one analog or eight digital channels. Integrated RF: MDO models (MDO3054, MDO4054-6, MDO4104-6) include a dedicated RF input and spectrum analysis capability so analog, digital and RF activity is time‑correlated in one box. Record length and capture rate: high‑end MSO and DPO products advertise very deep record lengths and high waveform capture or display rates to expose rare events (for example large standard or optional record lengths and high waveform capture rates appear across the DPO, MSO and DPO7000 listings).

How to choose between models

Start with the measurement requirements: required analog bandwidth and how much of the waveform detail you must resolve dictates the bandwidth and sample rate. If you need simultaneous digital logic capture or many logic channels, prioritize MSO family models that list FlexChannel or explicit digital channel counts. If RF spectrum analysis or an integrated spectrum trace is needed, focus on MDO models with the dedicated RF channel. For the highest single‑edge timing or fastest serial links consider DPO/DPO7000 and MSO6000/6 Series‑class sample rates and rise time specs. If your application needs a modular, very‑high‑frequency or TDR/TDT capability, the DSA8200 mainframe accepts specialized modules. Finally, balance channel count, record length and waveform capture rate: longer records and higher capture rates make it easier to find intermittent faults or capture long test sequences.

Frequently asked questions

What does FlexChannel mean and which models offer it?
FlexChannel is a front‑end architecture that lets a single input be used either as an analog channel or as a bundle of digital logic inputs. Models that document FlexChannel-style inputs in the provided data include MSO58 (8 FlexChannel inputs) and MSO64 (4 FlexChannel inputs).
When should I pick an MDO model instead of an MSO or DPO?
Pick an MDO model when you need time‑correlated RF spectrum analysis together with analog and digital capture in one instrument. Examples in the product list with integrated RF channels are MDO3054, MDO4054-6 and MDO4104-6. If you only need mixed analog + logic without RF, an MSO is typically the closer fit; if you need the highest single‑edge resolution or maximum sampling rate, a DPO/DPO7000‑class scope can be preferable.
How do bandwidth, sample rate and record length interact for practical measurements?
Bandwidth determines the frequency content the front end passes; sample rate determines the time resolution of captured waveforms; record length determines how long or how many samples you can store at that rate. The Tektronix models in the table offer tradeoffs across these three axes — for example some MSO and DPO products advertise multi‑GHz analog bandwidths with multi‑GS/s sample rates or very deep record lengths (see the per‑model specifications in the table for exact figures).